Beurer BM 60: Deleting saved values 6. Calling up stored values 7. Cleaning and storing the instrument
Deleting saved values 6. Calling up stored values 7. Cleaning and storing the instrument: Beurer BM 60
Table of contents
- 2. Important information Signs and symbols 1. Getting to know your instrument
- Advice on use
- Notes on handling batteries Storage and Care Repair and disposal
- Icons in the display: 3. Unit description 4. Getting started
- Operation with the mains part Setting date and time
- 5. Measuring blood pressure 5.1 Positioning cuff 5.2 Correct posture 5.3 Measuring blood pressure
- WHO classification: 5.4 Evaluating results Cardiac arrhythmia:
- Range of blood pressure values : haemodynamic stability : lack of haemodynamic stability
- Deleting saved values 6. Calling up stored values 7. Cleaning and storing the instrument
- 8. Rectifying faults 9. Specifications
- 10. Mains part

If the following measurement shows a lack of stability again,
•
If you press the memory buttons again, further individual
repeat the measurement after another period of rest. In case of
measurements appear with WHO, cardiac arrythmia and
further unstable measurements, identify these measurements
HSD. These individual values are numbered from 1 to 60. The
as they were taken when the circulatory system had not be suf-
time and date are alternately displayed after 2.5 seconds.
ficiently rested.
•
If there are 60 individual values in the memory at the same
In this case, inner unrest of the nervous system could be the
time, the oldest value is deleted in order to make room for
cause, which cannot be cured by brief periods of rest. Devel-
the new value.
oping cardiac arrhythmia can also prevent stable blood pres-
•
Use the start/stop button to turn off the device, or it will
sure measurements.
turn off automatically after approx. 30 seconds.
A lack of resting blood pressure can have various causes, such
Tip: You can also use the 2 user memories to separately store
as physical or mental strain or distraction and speaking or expe-
measurements – e.g. mornings and evenings.
riencing heart rhythmic disturbance during the measurement.
Deleting saved values
In an overwhelming number of cases, the HSD diagnosis will
You can delete saved values individually or else you can delete
give a very good guide as to whether the circulatory system is
all of them.
rested when taking the measurement. Certain patients suffering
•
To delete individual values, first select the stored value
from cardiac arrhythmia or chronic mental conditions can remain
you wish to delete and keep memory button M1 or M2
haemodynamically unstable in the long-term, something which
depressed. The display starts blinking. Keep holding the but-
persists even after repeated periods of rest. The precision of the
ton depressed until the display has completely cleared.
results of the resting blood pressure is reduced in these users.
•
To delete an entire user memory, you have to select the
Like any medical measurement method, the precision of the HSD
appropriate user memory. The average is displayed and indi-
diagnosis is limited and can lead to incorrect results in some
cated with . Hold the memory button M1 or M2 depressed
cases. The blood pressure measurements taken when the circu-
until the display starts blinking and keep the button
latory system was at rest represent particularly reliable results.
depressed until the display completely clears.
6. Calling up stored values
7. Cleaning and storing the instrument
You can call up values from the 2 user memories and display the
•
Clean your device and cuff carefully only with a slightly mois-
averages.
tened cloth.
•
Press the M1 or M2 memory buttons. Firstly, the average of
•
The frequency of cleaning depends on the contamination
all values stored in this user memory will be displayed. This
level of the device. Clean the blood pressure device and cuff
is denoted by the letter in the display.
as soon as any dirt appears on the device.