Braun 790cc Series 7: English
English: Braun 790cc Series 7
Our products are designed to meet the highest
English
standards of quality, functionality and design.
We hope you enjoy your new Braun Shaver.
Warning
Your shaving system is provided with a special
cord set, which has an integrated Safety Extra
Low Voltage power supply. Do not exchange or
STOPSTOP
tamper with any part of it, otherwise there is risk
of an electric shock.
This appliance is not intended for use by children
or persons with reduced physical or mental
capabilities, unless they are supervised by a
person responsible for their safety. In general,
we recommend that you keep the appliance out
of reach of children.
To prevent the cleaning fl uid from leaking, ensure
that the Clean&Renew station is placed on a fl at
surface. When a cleaning cartridge is installed,
do not tip, move suddenly or transport the
station in any way as cleaning fl uid might spill
out of the cartridge. Do not place the station
inside a mirror cabinet, nor over a radiator, nor
place it on a polished or lacquered surface.
The cleaning cartridge contains a highly
fl ammable liquid so keep it away from sources of
ignition. Do not smoke near the station. Do not
expose to direct sunlight for long periods of time.
Do not refi ll the cartridge and use only original
Braun refi ll cartridges.
Description
Clean&Renew station
1 Cleaning fl uid display
2 Lift button for cartridge exchange
3 Station-to-shaver contacts
4 «clean & dry» button
D «fast clean» button
5 Cleaning program indicators
6 Station power socket
7 Cleaning cartridge
Shaver
8 Foil & Cutter cassette
9 Cassette release button
0 Shaver head «lock» switch
q Pop-out long hair trimmer
4
98913707_790cc_CEEMEA_S4-110.ind4 498913707_790cc_CEEMEA_S4-110.ind4 4 03.02.2009 12:07:51 Uhr03.02.2009 12:07:51 Uhr
w On/off switch
e «sensitive» (–) setting button
r «intensive» (+) setting button
t Reset button
z Shaver display
u Shaver-to-station contacts
i Shaver power socket
o Travel case
p Special cord set
Before shaving
Prior to fi rst use you must connect the shaver to
an electrical outlet using the special cord set p
cle
cle
an
an
or alternatively proceed as below.
Installing the Clean&Renew station
• Using the special cord set p, connect the
station power socket 6 to an electrical outlet.
c
c
e
l
e
l
a
n
n
a
&
&
d
d
r
y
r
y
clean
clean
f
f
s
a
a
s
t
t
c
c
l
e
e
l
a
a
n
n
high
high
• Press the lift button 2 to open the housing.
low
low
1
1
empty
empty
2
2
• Hold the cleaning cartridge 7 down on a fl at,
f
f
a
a
s
s
t
t
c
c
l
e
e
l
a
a
n
n
stable surface (e.g. table).
new
new
• Carefully remove the lid from the cartridge.
e
l
c
c
l
e
a
a
n
n
&
&
d
d
r
r
y
y
cle
an
an
cle
e
l
c
c
e
l
a
n
n
a
&
d
d
&
r
y
y
r
clean
clean
a
f
a
f
s
t
t
s
c
c
l
e
a
l
e
a
n
n
high
high
low
low
f
a
f
a
s
s
t
t
l
c
c
l
e
a
e
a
n
n
• Slide the cartridge into the base of the station
empty
empty
high
high
low
low
empty
empty
as far as it will go.
f
a
f
a
s
s
t
c
t
c
l
e
e
l
a
a
n
n
a
f
a
f
s
s
t
t
c
c
l
l
e
e
a
a
n
n
• Slowly close the housing by pushing it down
until it locks.
The cleaning fl uid display 1 will show how much
fl uid is in the cartridge:
high
high
high
high
high
high
«high» up to 30 cleaning cycles available
low
low
low
low
low
low
«low» up to 7 cleaning cycles remaining
empty
empty
empty
empty
empty
empty
«empty» new cartridge required
Charging and cleaning the shaver
Insert the shaver head down into the cleaning
station. (The contacts u on the back of the
shaver will align with the contacts 3 in the
cleaning station).
If required, the Clean&Renew station will auto-
c
l
e
a
n
&
d
r
y
clean
matically charge the shaver. The hygiene status
high
low
empty
of the shaver will also be analyzed and one of
the following cleaning program indicators 5 will
light up:
5
reset
trim
mer
Series 7
l
c
e
a
n
&
d
y
r
clean
high
f
a
s
t
c
e
l
a
n
low
empty
reset
trim
mer
Series 7
f
a
s
t
c
l
e
a
n
98913707_790cc_CEEMEA_S4-110.ind5 598913707_790cc_CEEMEA_S4-110.ind5 5 03.02.2009 12:07:53 Uhr03.02.2009 12:07:53 Uhr
l
l
e
e
a
a
n
n
&
&
d
d
r
r
«clean» shaver is clean
c
c
y
y
clean
clean
«
» short economical cleaning required
« » normal level of cleaning required
« » high intensive cleaning required
f
f
a
a
s
s
t
t
c
c
l
l
e
e
a
a
n
n
If the station selects one of the required cleaning
programs, it will not start unless you press
c
c
l
l
e
e
a
a
n
n
&
&
d
d
r
r
y
y
clean
clean
the «clean & dry» button
4. For best shaving
f
f
a
a
s
s
t
t
c
c
l
e
l
e
a
a
n
n
results, we recommend cleaning after each
high
high
low
low
shave.
Whilst cleaning is in progress, the respective
cleaning program indicator will blink. Each
cleaning program consists of several cycles,
where cleaning fl uid is fl ushed through the
shaver head and a heat drying process dries
the shaver. Depending on the program selected
the total cleaning time will range from 32 to 43
minutes.
The cleaning programs should not be inter-
rupted. Please note that whilst the shaver is
drying, the shaving head may be hot and wet.
l
l
e
e
a
a
n
n
&
&
d
d
r
r
c
c
y
y
When the program is fi nished, the blue «clean»
clean
clean
indicator will light up. Your shaver is now clean
and ready for use.
f
f
a
a
s
s
t
t
c
c
l
l
e
e
a
a
n
n
Fast cleaning
Push the «fast clean» button D to activate
c
c
e
l
l
e
a
a
n
n
&
&
d
d
r
r
y
y
clean
clean
the fast clean program without drying. This
program takes about 25 seconds only and is
f
f
a
a
s
s
t
t
c
c
l
e
e
l
a
a
n
n
high
high
low
low
recommended when you do not have time to
empty
empty
wait for one of the automatic cleaning programs.
If you remove the shaver just after the program
has fi nished, wipe off the shaver head with a
tissue to avoid dripping.
Stand-by mode
10 minutes after completing the charging or
cleaning session, the Clean&Renew station
switches to the stand-by mode: The indicators
of the Clean&Renew station turn off.
Shaver display
The shaver display z shows the charge status of
h
h
the battery on the left, and the hygiene status on
y
y
y
y
r
r
g
g
e
e
t
t
i
i
t
t
e
e
the right. (6 dark segments are shown on each
a
a
n
n
b
b
e
e
side when the battery is fully charged and the
shaver is hygienically clean).
6
98913707_790cc_CEEMEA_S4-110.ind6 698913707_790cc_CEEMEA_S4-110.ind6 6 03.02.2009 12:07:53 Uhr03.02.2009 12:07:53 Uhr
Battery segments:
During charging or when using the shaver, the
respective battery segments will blink. When
fully charged all 6 segments are shown. With
decreasing charge the segments gradually
disappear.
Low charge indicator:
The «low» charge indicator provided with a red
frame blinks to indicate that the charge has
h
h
y
y
r
r
y
y
g
g
dropped below 20%. The remaining battery
e
e
t
t
t
t
e
i
e
i
a
a
n
n
b
b
e
e
capacity is suffi cient for 2 to 3 shaves.
Hygiene segments:
All 6 hygiene segments will appear after the
shaver has been cleaned in the Clean&Renew
h
y
y
r
g
e
t
t
e
i
station. When the shaver is being used, the
a
n
b
e
hygiene segments will gradually disappear.
Once the shaver is returned to the station, the
system will automatically select the appropriate
cleaning program and restore the segments
to maximum hygiene. Given that rinsing the
shaver under tap water is not as hygienic as the
cleaning station, the hygiene segments will only
restore themselves when the shaver has been
cleaned in the Clean&Renew station.
Charging information
• A full charge provides up to 50 minutes
of cordless shaving time. This may vary
according to your beard growth.
• The best environmental temperature for
charging is between 5 °C to 35 °C. Do not
expose the shaver to temperatures higher than
50 °C for extended periods of time.
Personalizing your shaver
Personalizing your shaver
With the «sensitive» e and «intensive» r
buttons you can choose the best setting for
shaving different areas of your face and as per
your specifi c needs. The different settings are
indicated by the pilot light incorporated in the
on/off switch w:
• «Intensive» = dark blue (powerful shave)
• «Normal» = light blue
• «Sensitive» = white (for a thorough comfortable
shave in sensitive areas of your
face such as neck)
7
b
a
t
a
t
e
r
y
r
h
y
y
r
g
e
t
i
t
e
a
n
b
e
b
a
t
a
t
e
r
y
r
on
on
off
off
n
siv
e
s
on
on
off
off
itive
n
siv
e
s
on
on
off
off
itive
n
siv
e
s
sensitivenormalintensive
on
on
off
off
itive
n
siv
e
s
on
on
off
off
itive
n
siv
e
s
on
on
off
off
itive
n
siv
e
s
sensitivenormalintensive
itive
98913707_790cc_CEEMEA_S4-110.ind7 798913707_790cc_CEEMEA_S4-110.ind7 7 03.02.2009 12:07:55 Uhr03.02.2009 12:07:55 Uhr
For a thorough and fast shave we recommend
the «intensive» setting.
Pressing the « + » or « – » button activates your
preferred setting. When switching on next time,
the last used setting will be activated.
How to use
Press the on/off switch
w to operate the shaver:
• The pivoting shaver head and fl oating foils
automatically adjust to every contour of your
face.
• To shave hard to reach areas (e.g. under the
nose) slide the shaver head «lock» switch
0 to
the back position to lock the pivoting head at
an angle.
• To trim sideburns, moustache or beard, slide
the pop-out long hair trimmer upwards.
Tips for the perfect shave
For best shaving results, Braun recommends you
follow 3 simple steps:
1. Always shave before washing your face.
2. At all times, hold the shaver at right angles
(90°) to your skin.
3. Stretch your skin and shave against the
direction of your beard growth.
Shaving with the cord
If the shaver has run out of power (discharged),
and you do not have the time to recharge it in the
Clean&Renew station, you may also shave with
the shaver connected to an electrical outlet via
the special cord set.
Cleaning
Automatic cleaning
After each shave, return the shaver to the
Clean&Renew station and proceed as described
above in the section «Before shaving».
All charging and cleaning needs are then
automatically taken care of. With daily use, a
cleaning cartridge should be suffi cient for about
30 cleaning cycles.
The hygienic cleaning cartridge contains alcohol,
which once opened will naturally evaporate
slowly into the surrounding air. Each cartridge,
if not used daily, should be replaced after
approximately 8 weeks.
8
tr
reset
lock
2
1
trimmer
lock
lock
lock
on
off
sensitive
intensive
on
off
tr
reset
lock
2
1
trimmer
lock
lock
lock
on
off
sensitive
intensive
on
off
releaserelease
c
l
e
a
n
&
d
r
y
clean
high
low
empty
e
t
s
re
trimmer
l
c
a
e
n
&
d
r
y
clean
high
f
a
s
t
c
e
l
a
n
low
empty
e
t
s
re
trimmer
f
a
s
t
c
l
e
a
n
98913707_790cc_CEEMEA_S4-110.ind8 898913707_790cc_CEEMEA_S4-110.ind8 8 03.02.2009 12:07:55 Uhr03.02.2009 12:07:55 Uhr
The cleaning cartridge also contains lubricants,
which may leave residual marks on the outer foil
frame after cleaning. However, these marks can
be removed easily by wiping gently with a cloth
or soft tissue paper.
Manual cleaning
The shaver head is suitable for cleaning
under running tap water.
Warning: Detach the shaver from the
power supply before cleaning the shaver
head in water.
Rinsing the shaving head under running water
trimmer
is an alternative way to keep the shaver clean,
especially when travelling:
• Switch the shaver on (cordless) and rinse
the shaving head under hot running water.
You may use liquid soap without abrasive
substances. Rinse off all foam and let the
shaver run for a few more seconds.
• Next, switch off the shaver, press the release
button 9 to remove the Foil & Cutter cassette
8 and let it dry.
oil
• If you regularly clean the shaver under
water, then once a week apply a drop of
light machine oil on top of the Foil & Cutter
cassette.
Alternatively, you may clean the shaver using the
brush provided:
• Switch off the shaver. Remove the Foil & Cutter
cassette 8 and tap it out on a fl at surface.
Using the brush, clean the inner area of the
pivoting head. However, do not clean the
cassette with the brush as this may damage it.
Cleaning the housing
From time to time clean the housing of the
shaver and the Clean&Renew station with a
damp cloth, especially inside the cleaning
chamber where the shaver rests.
Replacing the cleaning cartridge
After having pressed the lift button 2 to open the
housing, wait for a few seconds before removing
the used cartridge to avoid any dripping.
Before discarding the used cartridge, make sure
to close the openings using the lid of the new
cartridge, since the used cartridge will contain
contaminated cleaning solution.
9
on
re
le
a
s
e
er
re
le
a
s
e
trimmer
re
le
a
s
e
trimmer
Series
Series
oil
Series 7
click!
Series 7
on
re
le
a
s
e
er
re
le
a
s
e
trimmer
re
le
a
s
e
Series
Series
Series 7
click!
Series 7
Series 7
Series 7
a
le
re
le
re
a
s
s
e
e
Series 7
Series 7
re
le
le
re
a
a
s
s
e
e
le
le
re
re
a
s
a
s
e
e
new
new
old
old
98913707_790cc_CEEMEA_S4-110.ind9 998913707_790cc_CEEMEA_S4-110.ind9 9 03.02.2009 12:07:56 Uhr03.02.2009 12:07:56 Uhr
Keeping your shaver in top shape
Replacing the Foil & Cutter cassette
/
reset
To maintain 100% shaving performance, re-
y
y
r
r
h
h
place the Foil & Cutter cassette 8, when the
e
e
y
y
t
t
t
t
g
g
a
a
i
i
e
e
b
b
replacement symbol lights up on the shaver
n
n
e
e
display z (after about 18 months) or when
cassette is worn.
The replacement symbol will remind you during
the next 7 shaves to replace the Foil & Cutter
cassette. Then the shaver will automatically reset
the display.
After you have replaced the Foil & Cutter
cassette, use a ball-pen to push the reset button
t for at least 3 seconds to reset the counter.
While doing so, the replacement light blinks and
goes off when the reset is complete. The manual
reset can be done at any time.
Accessories
Available at your dealer or Braun Service
Centres:
• Foil & Cutter cassette 70S
• Cleaning cartridge Clean&Renew CCR
Environmental notice
This product contains rechargeable
batteries. In the interest of protecting the
environment, please do not dispose of the
product in household waste at the end of
its useful life. Disposal can take place at a
Braun Service Centre or at appropriate
collection points provided in your country.
The cleaning cartridge can be disposed with
regular household waste.
Subject to change without notice.
This product conforms to the European
Directives EMC 2004/108/EC and Low
Voltage 2006/95/EC.
For electric specifi cations, see printing on the
special cord set.
10
m
Series 7
re
le
a
s
e
70S
er
m
Series 7
re
le
a
s
e
70S
er
70S70S
98913707_790cc_CEEMEA_S4-110.ind10 1098913707_790cc_CEEMEA_S4-110.ind10 10 03.02.2009 12:07:57 Uhr03.02.2009 12:07:57 Uhr
Guarantee
We grant 2 years guarantee on the product
commencing on the date of purchase. Within
the guarantee period we will eliminate, free of
charge, any defects in the appliance resulting
from faults in materials or workmanship, either
by repairing or replacing the complete appliance
as we may choose.
This guarantee extends to every country where
this appliance is supplied by Braun or its
appointed distributor.
This guarantee does not cover: damage due
to improper use, normal wear and tear (e.g. foil
& cutter cassette) as well as defects that have
a negligible effect on the value or operation of
the appliance. The guarantee becomes void if
repairs are undertaken by unauthorised persons
and if original Braun parts are not used.
To obtain service within the guarantee period,
hand in or send the complete appliance with
your sales receipt to an authorised Braun
Customer Service Centre.
For UK only:
This guarantee in no way affects your rights
under statutory law.
11
98913707_790cc_CEEMEA_S4-110.ind11 1198913707_790cc_CEEMEA_S4-110.ind11 11 03.02.2009 12:07:58 Uhr03.02.2009 12:07:58 Uhr