Beurer TL 40: 10. Disposal 11. What if there are problems? 12. Technical specifications

10. Disposal 11. What if there are problems? 12. Technical specifications: Beurer TL 40

10. Disposal

In the interest of protecting the environment, the unit must not be thrown out with the household

waste at the end of its service life. Dispose of the unit at a suitable local collection or recycling

point.

Dispose of the device in accordance with EC Directive 2002/96/EC–WEEE(WasteElectricaland

ElectronicEquipment).Ifyouhaveanyquestions,pleasecontactthelocalauthoritiesresponsiblefor

waste disposal.

11. What if there are problems?

Problem Possible cause Solution

Device does not

On/off button switched off Switch on the on/off button.

light up

No electricity Connect the mains plug correctly.

No electricity The mains cable is defective. Contact

customer services or your retailer.

The fluorescent tube is not correctly inserted Insert the fluorescent tube correctly.

(For a description, see the Quick guide

“Replacing the fluorescent tube”)

Fluorescent tube has reached the end of its

Replace the fluorescent tube.

service life. Fluorescent tube is defective.

(For a description, see the Quick guide

“Replacing the fluorescent tube”)

12. Technical specifications

Dimensions(WHD) 270x207x80mm

Weight

800g

Lighting elements MP 45 3U 45W tubes, Daylight

Power 45 watts

Light intensity 10,000lux(15cm)

Radiation Outputofradiationbeyondthevisiblespectrum(infraredandUV)is

so low that it is harmless to eyes and skin.

Mains connection 220-240 V ~, 50 Hz

Operatingconditions +10°C to +25°C, < 30-90% relative humidity,

700-1060hPa ambient pressure

Storage conditions -20°C to +50°C, relative humidity <90%,

700-1060hPa ambient pressure

Transport conditions -20°C to +50°C, relative humidity <90%,

700-1060hPa ambient pressure

Product classification Protection class II, IPX0, no AP or APG, continuous operation, no

ancillary parts

Degree of efficiency of the ballast ~ 96%

Source effiency (lm/W) of the bulb 67–71 lm/W

Color temperature of tubes 6.500 Kelvin

Subject to technical modifications.

This device meets the requirements of the European Directive 93/42/EEC and 2007/47/EEC Medical Devices as

wellastheMedicalDevicesAct.

This device complies with European Standard EN60601-1-2 and is subject to particular precautions with regard

to electromagnetic compatibility. Please note that portable and mobile HF communication systems may interfere

with this unit. More details can be requested from the stated customer service address or found at the end of the

instructions for use.