Hotpoint-Ariston C 34S N1 R: In st alla t ion

In st alla t ion: Hotpoint-Ariston C 34S N1 R

background image

1

4

G

B

 Before operating 

y

our new appliance please read

this  instruction  booklet  carefull

y

.  It  contains

important  information  concerning  the  safe  installation

and operation of the appliance.

 Please keep these operating instructions for future

reference. Make sure that the instructions are kept

with the appliance if it is sold, given awa

y

 or moved.

 The appliance must be installed b

y

 a qualified

professional  according  to  the  instructions  provided.

 An

y

 necessar

y

 adjustment or maintenance must be

performed after the cooker has been disconnected

from  the  electricit

y

  suppl

y

.

Room

ven

t

i

l

a

t

i

on

The appliance ma

y

 onl

y

 be installed in permanentl

y

-

ventilated rooms, according to current national

legislation. The room in which the appliance is

installed  must  be  ventilated  adequatel

y

  so  as  to

provide as much air as is needed b

y

 the normal gas

combustion process (the flow of air must not be

lower than 2 m

3

/h per kW of installed power).

The air inlets, protected b

y

 grilles, should have a

duct with an inner cross section of at least 100 cm

2

and should be positioned so that the

y

 are not liable

to even partial obstruction (

see figure A

).

These inlets should be enlarged b

y

 100% - with a

minimum of 200 cm

2

 - whenever the surface of the

hob is not equipped with a flame failure safet

y

device. When the flow of air is provided in an

indirect manner from adjacent rooms (

see figure B

),

provided that these are not communal parts of a

building, areas with increased fire hazards or

bedrooms, the inlets should be fitted with a

ventilation  duct  leading  outside  as  described  above.

 After prolonged use of the appliance, it is

advisable to open a window or increase the speed of

an

y

  fans  used.

D

i

spos

i

ng

o

com

b

us

t

i

on

  f

umes

The disposal of combustion fumes should be

guaranteed using a hood connected to a safe and

efficient natural suction chimne

y

, or using an electric

fan that begins to operate automaticall

y

 ever

y

 time

the appliance is switched on (

see figure

).

 The liquefied petroleum gases are heavier than air

and collect b

y

 the floor, therefore all rooms

containing LPG c

y

linders must have openings

leading outside so that an

y

 leaked gas can escape

easil

y

.

LPG c

y

linders, therefore, whether partiall

y

 or

completel

y

 full, must not be installed or stored in

rooms or storage areas that are below ground level

(cellars, etc.). Onl

y

 the c

y

linder being used should

be stored in the room; this should also be kept well

awa

y

 from sources of heat (ovens, chimne

y

s,

stoves) that ma

y

 cause the temperature of the

c

y

linder to rise above 50°C.

P

o

s

iti

on

i

n

a

n

l

eve

ll

i

n

g

 It is possible to install the appliance alongside

cupboards whose height does not e

x

ceed that of the

hob  surface.

 Make sure that the wall in contact with the back of

the appliance is made from a non-flammable, heat-

resistant material (T 90°C).

To install the appliance correctl

y

:

• Place it in the kitchen, the dining room or the bed-

sit (not in the bathroom).

• If the top of the hob is higher than the cupboards,

the appliance must be installed at least 200 mm

awa

y

 from them.

• If the cooker is installed underneath a wall cabinet,

there must be a minimum distance of 420 mm

between this cabinet and the top of the hob.

This distance should be increased to 700 mm if the

wall cabinets are flammable (

see figure

).

A

In st alla t ion

Ventilation  opening  for

comburent air

Increase in the gap

between the door and

the  flooring

Adjacent room

Room requiring

ventilation

A

B

Fumes channelled

straight  outside

Fumes channelled through

a chimne

y

 or a branched

flue  s

y

stem  (reserved  for

cooking  appliances)

background image

1

5

G

B

• Do not position blinds

behind the cooker or

less than 200 mm awa

y

from its sides.

• An

y

 hoods must be

installed  according  to

the  instructions  listed  in

the  relevant  operating

manual.

L

evell

i

ng

If it is necessar

y

 to level the

appliance, screw the

adjustable feet into the places

provided on each corner of the

base of the cooker (

see

figure

).

The legs* fit into the slots on

the underside of the base of

the  cooker.

HOOD

420

Min.

min. 

650

 mm. with hood

min. 

700

 mm. without hood

mm.

600

Min.

mm.

420

Min.

mm.

* Onl

y

 available in certain models.

E

l

ec

t

r

i

c

a

l

 c

onn

ec

ti

on

s

Install a standardised plug corresponding to the

load indicated on the appliance data plate (

see

Technical data table

).

The appliance must be directl

y

 connected to the

mains using an omnipolar circuit-breaker with a

minimum contact opening of 3 mm installed between

the appliance and the mains. The circuit-breaker

must be suitable for the charge indicated and must

compl

y

 with NFC 15-100 regulations (the earthing

wire must not be interrupted b

y

 the circuit-breaker).

The suppl

y

 cable must be positioned so that it does

not come into contact with temperatures higher than

50°C at an

y

 point.

Before connecting the appliance to the power

suppl

y

,  make  sure  that:

• The appliance is earthed and the plug is compliant

with the law.

• The socket can withstand the ma

x

imum power of

the appliance, which is indicated b

y

 the data plate.

• The voltage is in the range between the values

indicated on the data plate.

• The socket is compatible with the plug of the

appliance. If the socket is incompatible with the

plug, ask an authorised technician to replace it.

Do not use e

x

tension cords or multiple sockets.

 Once the appliance has been installed, the power

suppl

y

 cable and the electrical socket must be

easil

y

  accessible.

 The cable must not be bent or compressed.

The cable must be checked regularl

y

 and replaced

b

y

  authorised  technicians  onl

y

.

The

m

a

nu

f

a

c

t

urer

decl

i

nes

a

n

l

ia

b

i

l

i

t

should

t

hese

s

a

f

e

t

me

a

sures

no

t

 b

e

o

b

served

.

G

a

s

connec

t

i

on

Connection to the gas network or to the gas c

y

linder

ma

y

 be carried out using a fle

x

ible rubber or steel

hose, in accordance with current national legislation

and after making sure that the appliance is suited to

the t

y

pe of gas with which it will be supplied (see

the rating sticker on the cover:  if this is not the case

see below

). When using liquid gas from a c

y

linder,

install a pressure regulator which complies with

current national regulations. To make connection

easier,  the  gas  suppl

y

  ma

y

  be  turned  sidewa

y

s*:

reverse the position of the hose holder with that of

the cap and replace the gasket that is supplied with

the  appliance.

 Check that the pressure of the gas suppl

y

 is consistent

with the values indicated in the Table of burner and

nozzle specifications (

see below

). This will ensure the

safe operation and durabilit

y

 of 

y

our appliance while

maintaining efficient energ

y

 consumption.

G

a

s

connec

t

i

on

us

i

ng

a

 f

le

x

i

b

le

ru

bb

er

hose

Make sure that the hose complies with current

national legislation. The internal diameter of the hose

must measure: 8 mm for liquid gas suppl

y

; 13 mm

for  methane  gas  suppl

y

.

Once the connection has been performed, make

sure that the hose:

• Does not come into contact with an

y

 parts that

reach temperatures of over 50°C.

•

Is not subject to an

y

 pulling or twisting forces

and that it is not kinked or bent.

• Does not come into contact with blades, sharp

corners or moving parts and that it is not

compressed.

• Is eas

y

 to inspect along its whole length so that

its condition ma

y

 be checked.

• Is shorter than 1500 mm.

• Fits firml

y

 into place at both ends, where it will be

fi

x

ed using clamps that compl

y

 with current

regulations.

background image

1

6

G

B

Connec

t

i

ng

a

  f

le

x

i

b

le

  j

o

i

n

t

less

s

t

ai

nless

s

t

eel

p

i

pe

t

o

a

t

hre

a

ded

a

tt

a

chmen

t

Make sure that the hose and gaskets compl

y

 with

current  national  legislation.

To begin using the hose, remove the hose holder on

the appliance (the gas suppl

y

 inlet on the appliance

is a c

y

lindrical threaded 1/2 gas male attachment).

 Perform the connection in such a wa

y

 that the hose

length does not e

x

ceed a ma

x

imum of 2 metres,

making sure that the hose is not compressed and

does not come into contact with moving parts.

Chec

k

i

ng

t

he

connec

t

i

on

 f

or

le

a

k

s

 When the installation process is complete, check

the  hose  fittings  for  leaks  using  a  soap

y

  solution.

Never use a flame.

A

d

a

p

ti

n

t

o

 d

iff

ere

n

t

ty

pes 

o

f

 g

a

s

It is possible to adapt the appliance to a t

y

pe of gas

other than the default t

y

pe (this is indicated on the

rating label on the cover).

Ad

a

p

t

i

ng

t

he

ho

b

Replacing the nozzles for the hob burners:

1. Remove the hob grids and slide the burners off

their  seats.

2. Unscrew the nozzles using

a 7 mm socket spanner (

see

figure

), and replace them with

nozzles suited to the new t

y

pe

of gas (

see Burner and nozzle

specifications  table

).

3. Replace all the components

b

y

 following  the above instructions in reverse.

Adjusting  the  hob  burners’  minimum  setting:

1. Turn the tap to the minimum position.

2. Remove the knob and adjust the regulator

y

screw, which is positioned inside or ne

x

t to the tap

pin,  until  the  flame  is  small  but  stead

y

.

 If the appliance is connected to a liquid gas

suppl

y

,  the  regulator

y

  screw  must be fastened as

tightl

y

 as possible.

3. While the burner is alight, quickl

y

 change the position

of the knob from minimum to ma

x

imum and vice versa

several times, checking that the flame is not

e

x

tinguished.

 The hob burners do not require primar

y

 air adjustment.

 After adjusting the appliance so it ma

y

 be used

with a different t

y

pe of gas, replace the old rating

label with a new one that corresponds to the new

t

y

pe of gas (these labels are available from

Authorised  Technical  Assistance  Centres).

 Should the gas pressure used be different (or var

y

slightl

y

)  from  the  recommended  pressure,  a  suitable

pressure regulator must be fitted to the inlet hose in

accordance with current national regulations relating

to “regulators for channelled gas”.

 If one or more of these conditions is not fulfilled or

if the cooker must be installed according to the

conditions listed for class 2 - subclass 1 appliances

(installed  between  two  cupboards),  the  fle

x

ible  steel

hose must be used instead (

see below

).

TECHNICAL DATA

Oven dimensions

(HxWxD)

34x38x44 cm

Volume

57 l

Useful

measurements

relating to the

oven

compartment

width 42 cm

depth 44 cm

height 17 cm

Power supply

voltage and

frequency

see data plate

Burners

may be adapted for use with any

type of gas shown on the data

plate, which is located inside the

flap or, after the oven compartment

has been opened, on the left-hand

wall inside the oven.

ENERGY LABEL

Directive 2002/40/EC on the label

of electric ovens. Standard EN

50304

Declared energy consumption for

Natural convection Class – heating

mode: 

=

=

Static

EC Directives: 73/23/EEC dated

19/02/73 (Low Voltage) and

subsequent amendments -

89/336/EEC dated 03/05/89

(Electromagnetic Compatibility) and

subsequent amendments -

90/369/EEC dated 29/06/90 (Gas)

and subsequent amendments -

93/68/EEC dated 22/07/93 and

subsequent amendments -

2002/96/EC.

background image

1

7

G

B

T

ab

l

o

f

b

ur

n

er 

a

n

no

zz

l

e spec

ifi

c

ati

on

s

T

a

b

le

1

L

i

q

uid

G

as

N

atural

G

as

D

iameter

(

mm

)

Th

ermal

P

o

w

er

kW

(

p

.c.s.

*)

By

P

ass

1/100

N

o

zz

le

1/100

F

lo

w*

g/h

N

o

zz

le

1/100

F

lo

w*

l

/h

N

o

zz

le

1/100

F

lo

w*

l

/h

B

urner

N

ominal

R

educed

(

mm

)

(

mm

)

***

**

(

mm

)

(

mm

)

F

ast

(L

ar

g

e

)(

R

)

100

3

.

00

0

.

7

41

87

218

214

128

286

143

286

S

emi

F

ast

(

M

edium

)(

S

)

75

1

.

90

0

.

4

30

70

138

136

104

181

118

181

A

u

x

iliar

y

(

S

mall

)(

A

)

51

1

.

00

0

.

4

30

52

73

71

76

95

80

95

S

u

pp

l

y

P

ressures

N

ominal

(

m

b

ar

)

M

inimum

(

m

b

ar

)

M

a

x

imum

(

m

b

ar

)

28-30

20

35

37

25

45

20

17

25

13

6,5

18

*

A

t

15°C

1013

m

b

ar

-

dr

y

g

as

***

B

utane

P

.

C

.

S

.

=

49,47

M

J

/

K

g

**

P

ro

p

ane

P

.

C

.

S

.

=

50,37

M

J

/

K

g

    

N

atural

P

.

C

.

S

.

=

37,78

M

J

/

m

³

S S

R

A

C

3

4

S

N

1

R

/HA