• Liquid petroleum gas sinks to the oor as it is heavier
Installation
than air. Therefore, rooms containing LPG cylinders must
GB
also be equipped with vents to allow gas to escape in
! Before operating your new appliance please read this
the event of a leak. As a result LPG cylinders, whether
instruction booklet carefully. It contains important information
partially or completely full, must not be installed or stored
for safe use, installation and care of the appliance.
in rooms or storage areas that are below ground level
(cellars, etc.). It is advisable to keep only the cylinder
! Please keep these operating instructions for future reference.
being used in the room, positioned so that it is not subject
Pass them on to possible new owners of the appliance.
to heat produced by external sources (ovens, replaces,
stoves, etc. ) which could raise the temperature of the
Positioning
cylinder above 50°C.
! Keep packaging material out of the reach of children. It can
become a choking or suffocation hazard (see Precautions
Fitting the appliance
and tips).
Gas and mixed hobs are manufactured with type X degree
protection against overheating. The following precautions
! The appliance must be installed by a qualied professional
must be taken when installing the hob:
according to the instructions provided. Incorrect installation
• Kitchen cabinets adjacent to the appliance and taller than
may cause harm to people and animals or may damage
the top of the hob must be at least 600 mm from the edge
property.
of the hob.
! This unit may be installed and used only in permanently
• Hoods must be installed according to their relative
ventilated rooms in accordance with British Standard
installation instruction manuals and at a minimum
Codes Of Practice: B.S. 6172 / B.S. 5440, Par. 2 and B.S.
distance of 650 mm from the hob (see gure).
6891 Current Editions. The following requirements must
be observed:
• Place the wall cabinets adjacent to the hood at a minimum
height of 420 mm from the hob (see gure).
• The room must be equipped with an air extraction system
that expels any combustion fumes. This may consist of
If the hob is installed beneath a wall
a hood or an electric fan that automatically starts each
cabinet, the latter must be situated
time the appliance is switched on.
at a minimum of 700 mm above
the hob.
• The installation cavity should have the dimensions
In a chimney stack or branched flue.
Directly to
(exclusively for cooking appliances)
the Outside
indicated in the gure.
Fastening hooks are provided, allowing you to fasten
the hob to tops that are between 20 and 40 mm thick.
• The room must also allow proper air circulation, as air is
To ensure the hob is securely fastened to the top, we
needed for combustion to occur normally. The ow of air
3
recommend you use all the hooks provided.
must not be less than 2 m
/h per kW of installed power.
The air circulation system may
take air directly from the outside
by means of a pipe with an inner
2
cross section of at least 100 cm
;
A
the opening must not be vulnerable
to any type of blockages.
Examples of
ventilation holes
for comburant air.
Adjacent
Room to be
The system can also provide the air
Room
Vented
needed for combustion indirectly,
i.e. from adjacent rooms tted with
air circulation tubes as described
above. However, these rooms must
not be communal rooms, bedrooms
Enlarging the ventilation slot
or rooms that may present a re
between window and floor.
hazard.
23
555 mm
600mm min.
650mm min.
420mm min.
55 mm
475 mm

Hook fastening diagram
Electrical connection
GB
Hobs equipped with a three-pole power supply cable are
designed to operate with alternating current at the voltage and
frequency indicated on the data plate (this is located on the
lower part of the appliance). The earth wire in the cable has a
green and yellow cover. If the appliance is to be installed above
a built-in electric oven, the electrical connection of the hob and
the oven must be carried out separately, both for electrical
Hooking position Hooking position
safety purposes and to make extracting the oven easier.
for top H=20mm for top H=30mm
Connecting the supply cable to the mains
Front
Install a standardised plug corresponding to the load
indicated on the data plate.
The appliance must be directly connected to the mains
using an omnipolar circuit-breaker with a minimum contact
opening of 3 mm installed between the appliance and the
mains. The circuit-breaker must be suitable for the charge
indicated and must comply with current electrical regulations
(the earthing wire must not be interrupted by the circuit-
breaker). The supply cable must not come into contact with
surfaces with temperatures higher than 50°C.
Hooking position Back
for top H=40mm
! The installer must ensure that the correct electrical
connection has been made and that it is compliant with
! Use the hooks contained in the “accessory pack”.
safety regulations.
Before connecting to the power supply, make sure that:
• Where the hob is not installed over a built-in oven, a
wooden panel must be installed as insulation. This must
• The appliance is earthed and the plug is compliant with
be placed at a minimum distance of 20 mm from the lower
the law.
part of the hob.
• The socket can withstand the maximum power of the
appliance, which is indicated on the data plate.
Ventilation
• The voltage is in the range between the values indicated
To ensure adequate ventilation, the back panel of the cabinet
on the data plate.
must be removed. It is advisable to install the oven so that it
• The socket is compatible with the plug of the appliance.
rests on two strips of wood, or on a completely at surface
If the socket is incompatible with the plug, ask an
with an opening of at least 45 x 560 mm (see diagrams).
authorised technician to replace it. Do not use extension
cords or multiple sockets.
45 mm.
! Once the appliance has been installed, the power supply
560 mm.
cable and the electrical socket must be easily accessible.
! The cable must not be bent or compressed.
! The cable must be checked regularly and replaced by
authorised technicians only (see Assistance).
Where a hob is installed above an oven without a forced
ventilation cooling system, adequate ventilation must be
! The manufacturer declines any liability should these safety
provided inside the cabinet by means of air holes through
measures not be observed.
which air can pass (see gure).
Gas connection
The appliance should be connected to the main gas supply
or to a gas cylinder in compliance with current national
regulations. Before carrying out the connection, make sure
the cooker is compatible with the gas supply you wish to
use. If this is not the case, follow the instructions indicated
in the paragraph “Adapting to different types of gas.”
When using liquid gas from a cylinder, install a pressure
regulator which complies with current national regulations.
! Check that the pressure of the gas supply is consistent with the
values indicated in Table 1 (“Burner and nozzle specications”).
This will ensure the safe operation and longevity of your
appliance while maintaining efcient energy consumption.
24

Connection with a rigid pipe (copper or steel)
Replacing the Triple ring burner nozzles
! Connection to the gas system must be carried out in such a
1. Remove the pan supports and lift the burners out of their
GB
way as not to place any strain of any kind on the appliance.
housing. The burner consists of two separate parts (see
There is an adjustable L-shaped pipe tting on the appliance
pictures).
supply ramp and this is tted with a seal in order to prevent
2. Unscrew the nozzles using a 7 mm socket spanner.
leaks. The seal must always be replaced after rotating the
Replace the nozzles with models that are congured
pipe tting (seal provided with appliance). The gas supply
for use with the new type of gas (see Table 1). The two
pipe tting is a threaded 1/2 gas cylindrical male attachment.
nozzles have the same hole diameter.
3. Replace all the components by completing the above
Connecting a exible jointless stainless steel pipe to
operations in reverse order.
a threaded attachment
The gas supply pipe tting is a threaded 1/2 gas cylindrical
male attachment.
These pipes must be installed so that they are never longer
than 2000 mm when fully extended. Once connection has
been carried out, make sure that the exible metal pipe
does not touch any moving parts and is not compressed.
! Only use pipes and seals that comply with current national
regulations.
• Adjusting the burners’ primary air
Checking the tightness of the connection
Does not require adjusting.
! When the installation process is complete, check the pipe
ttings for leaks using a soapy solution. Never use a ame.
• Setting the burners to minimum
Adapting to different types of gas
1. Turn the tap to the low ame position;
To adapt the hob to a different type of gas other than default
type (indicated on the rating plate at the base of the hob or
2. Remove the knob and adjust
on the packaging), the burner nozzles should be replaced
the adjustment screw, which is
as follows:
positioned in or next to the tap pin,
until the ame is small but steady.
1. Remove the hob grids and slide the burners off their
seats.
2. Unscrew the nozzles using a 7 mm socket spanner, and
replace them with nozzles for the new type of gas (see
table 1 “Burner and nozzle characteristics”).
3. Reassemble the parts following the above procedure in
3. Having adjusted the ame to the required low setting,
the reverse order.
while the burner is alight, quickly change the position
4. Once this procedure is nished, replace the old rating
of the knob from minimum to maximum and vice versa
sticker with one indicating the new type of gas used.
several times, checking that the ame does not go out.
Sticker are available from any of our Service Centres.
4. Some appliances have a safety device (thermocouple)
tted. If the device fails to work when the burners are set
Replacing the nozzles on separate “double ame “
to the low ame setting, increase this low ame setting
burners
using the adjusting screw.
1. Remove the grids and slide the burners from their
5. Once the adjustment has been made, replace the
housings. The burner consists of 2 separate parts (see
seals on the by-passes using sealing wax or a similar
gure);
substance.
2. Unscrew the burers with a 7 mm wrench spanner. The
internal burner has a nozzle, the external burner has
! If the appliance is connected to liquid gas, the regulation
two (of the same size). Replace the nozzle with models
screw must be fastened as tightly as possible.
suited to the new type of gas (see table 1).
3. Replace all the components by repeating the steps in
! Once this procedure is nished, replace the old rating
reverse order.
sticker with one indicating the new type of gas used. Stickers
are available from any of our Service Centres.
! Should the gas pressure used be different (or vary slightly)
from the recommended pressure, a suitable pressure
regulator must be tted to the inlet pipe (in order to comply
with current national regulations).
25

DATA PLATE
GB
Electrical
see data plate
connections
This appliance conforms to the following
European Economic Community directives:
- 2006/95/EEC dated 12/12/06 (Low
Voltage) and subsequent amendments
- 2004/108/EEC dated 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 2009/142/EEC dated 30/11/09 (Gas) and
subsequent amendments.
- 2012/19/EC and subsequent
amendments.
26

GB
Burner Diameter Thermal Thermal By-pass Nozzle Flow* Thermal Nozzle Flow*
power power 1/100 1/100 (g/h) power 1/100 (l/h)
kW kW kW
(p.c.s.*) (p.c.s.*) (p.c.s.*)
(mm) Reduced Nominal (mm) (mm) *** ** Nominal (mm)
Fast (R)
100
0.70
3.00
39
86
218
214
3.00
132 (H)
286
Reduced Fast (RR)
100
0.70
2.60
39
80
189
186
2.60
122 (H)
248
Semi Fast (S)
75
0.40
1.65
28
64
120
118
1.65
96 (Z)
157
Auxiliary (A)
55
0.40
1.00
28
50
73
71
1.00
79 (6)
95
Triple Crown (TC)
130
1.50
3.30
61
65x2
240
236
3.60
103x2
343
Ultrarapid (UR)
100
0.70
3.40
39
91
247
243
3.40
138 (H)
324
Semi-Fishburner (SP)
—
0.70
1.50
39
60
109
107
1.50
88
143
Double Flame
30
0.40
0.90
28
44
65
64
0.90
74
86
(DCDR Internal)
Double Flame (DCDR
130
1.50
4.10
61
70x2
298
293
4.10
110x2
390
External) 2 nozzle
Nominal (mbar)
28-30
37
20
Supply pressures
Minimum (mbar)
20
25
17
Maximum (mbar)
35
45
25
AA
A
R
Ø145
R
S
RR
TC
S
S
S
PC 631 X/HA
PC 640 X/HA
PC 640 T X/HA
PC 631 /HA
PC 640 R/HA
PC 640 T GH/HA
PC 640 /HA
PC 640 T AX/HA
PC 640 T R/HA
PC 640T GH R /HA
PC 640 T E X/HA
27
Burner and nozzle specifications
Table 1 Liquid Gas Natural Gas
* At 15°C and 1013,25 mbar - dry gas
** Propane P.C.S. = 50.37 MJ/Kg
*** Butane P. C.S. = 49.47 MJ/Kg
Natural P.C.S. = 37.78 MJ/m³
S
RR
S
RR
S
RR
S
SP
DC
TC
UR
TC
SP
A
S
A
S
A A
PC 730 RT GH /HA
PC 750 X /HA
PC 750 T X /HA
PC 760 F X /HA
PC 730 RT X /HA
PC 750 AX /HA
PC 750 T AX /HA
PC 760 F R /HA
PC 750 T GH /HA
PC 750 T XX /HA
PC 750 T R /HA
PC 750 T /HA
PC 750 T E X/HA
Оглавление
- Mode d’emploi
- Bedienungsanleitung
- Avvertenze
- Avertissements
- Advertências
- Belangrijk
- Предупреждения
- Assistenza Assistance
- Assistência
- Descrizione dell’apparecchio Description of the appliance
- Description de l’appareil Descripción del aparato
- Descrição do aparelho Beschreibung Ihres Gerätes
- Beschrijving van het apparaat Описание изделия
- Installazione
- Avvio e utilizzo
- Precauzioni e consigli
- Anomalie e rimedi
- Installation
- Start-up and use
- Precautions and tips
- Troubleshooting
- Installation
- Mise en marche et utilisation
- Précautions et conseils
- Nettoyage et entretien
- Anomalies et remèdes
- Instalación
- Puesta en funcionamiento y
- Precauciones y consejos
- Mantenimiento y cuidados
- Instalação
- Início e utilização
- Precauções e conselhos
- Manutenção e cuidados
- Anomalias e soluções
- Installation
- Inbetriebsetzung und Gebrauch
- Vorsichtsmaßregeln und Hinweise
- Störungen und Abhilfe
- Het installeren
- Starten en gebruik
- Voorzorgsmaatregelen en
- Onderhoud en verzorging
- Установка
- Включение и эксплуатация
- Предосторожности и
- Техническое обслуживание
- Неисправности и методы их устранения