Hotpoint-Ariston C 35S P6 R/HA: I n st a ll a t io n
I n st a ll a t io n: Hotpoint-Ariston C 35S P6 R/HA

GB
15
Before operating your new appliance please read
this instruction booklet carefully. It contains important
information concerning the safe installation and
operation of the appliance.
Please keep these operating instructions for future
reference. Make sure that the instructions are kept
with the appliance if it is sold, given away or moved.
The appliance must be installed by a qualified
professional according to the instructions provided.
Any necessary adjustment or maintenance must be
performed after the cooker has been disconnected
from the electricity supply.
R
oo
m
v
e
n
ti
l
atio
n
The appliance may only be installed in permanently-
ventilated rooms, according to current national
legislation. The room in which the appliance is
installed must be ventilated adequately so as to
provide as much air as is needed by the normal gas
combustion process (the flow of air must not be lower
than 2 m
3
/h per kW of installed power).
The air inlets, protected by grilles, should have a duct
with an inner cross section of at least 100 cm
2
and
should be positioned so that they are not liable to
even partial obstruction (
see figure A
).
These inlets should be enlarged by 100% - with a
minimum of 200 cm
2
- whenever the surface of the hob
is not equipped with a flame failure safety device.
When the flow of air is provided in an indirect manner
from adjacent rooms (
see figure B
), provided that
these are not communal parts of a building, areas with
increased fire hazards or bedrooms, the inlets should
be fitted with a ventilation duct leading outside as
described above.
After prolonged use of the appliance, it is advisable to
open a window or increase the speed of any fans used.
Dis
p
osi
ng
o
f
c
o
m
b
u
stio
n
f
u
m
es
Disposing of combustion fumes should be guaranteed
using a hood connected to a safe and efficient natural
suction chimney, or using an electric fan that begins
to operate automatically every time the appliance is
switched on (
see figure
).
The liquefied petroleum gases are heavier than air
and collect by the floor, therefore all rooms containing
LPG cylinders must have openings leading outside so
that any leaked gas can escape easily.
LPG cylinders, therefore, whether partially or
completely full, must not be installed or stored in
rooms or storage areas that are below ground level
(cellars, etc.). Only the cylinder being used should be
stored in the room; this should also be kept well away
from sources of heat (ovens, chimneys, stoves) that
may cause the temperature of the cylinder to rise
above 50°C.
P
ositio
n
i
n
g
a
n
d
le
v
elli
n
g
It is possible to install the appliance alongside
cupboards whose height does not e
x
ceed that of the
hob surface.
Make sure that the wall in contact with the beck of
the appliance is made from a non-flammable, heat-
resistant material (T 90°C).
To install the appliance correctly:
Place it in the kitchen, dining room or the bed-sit
(not in the bathroom).
If the top of the hob is higher than the cupboards,
the appliance must be installed at least 200 mm
away from them.
I n st a ll a t io n
Adjacent
room
Room
requiring
ventilation
A
Ventilation
opening
for
comburent
air
Increase
in
the
gap
between
the
door
and
the
flooring
B
A
Fumes channelled
straight outside
Fumes channelled through
a chimney or a branched
flue system (reserved for
cooking appliances)

16
G
B
If the cooker is
installed underneath a
wall cabinet, there must
be a minimum distance
of 420 mm between this
cabinet and the top of
the hob.
This distance should be
increased to 700 mm if
the wall cabinets are
flammable (
see figure
).
Do not position blinds behind the cooker or less
than 200 mm away from its sides.
Any hoods must be installed according to the
instructions listed in the relevant operating manual.
L
e
v
e
ll
i
ng
If it is necessary to level the
appliance, screw the
adjustable feet into the places
provided on each corner of the
base of the cooker (
see figure
).
The legs* fit into the slots on
the underside of the base of
the cooker.
E
le
c
tri
c
al
c
o
nn
e
c
tio
n
Install a standardised plug corresponding to the load
indicated on the appliance data plate (
see Technical
data table
).
The appliance must be directly connected to the mains
using an omnipolar circuit-breaker with a minimum
contact opening of 3 mm installed between the appliance
and the mains. The circuit-breaker must be suitable for
the charge indicated and must comply with NFC 15-100
regulations (the earthing wire must not be interrupted by
the circuit-breaker). The supply cable must be positioned
so that it does not come into contact with temperatures
higher than 50°C at any point.
Before connecting the appliance to the power supply,
make sure that:
The appliance is earthed and the plug is compliant with
the law.
The socket can withstand the ma
x
imum power of
the appliance, which is indicated by the data plate.
HOOD
420
Min.
min.
650
mm. with hood
min.
700
mm. without hood
mm.
600
Min.
mm.
420
Min.
mm.
The voltage is in the range between the values
indicated on the data plate.
The socket is compatible with the plug of the
appliance. If the socket is incompatible with the
plug, ask an authorised technician to replace it. Do
not use e
x
tension cords or multiple sockets.
Once the appliance has been installed, the power
supply cable and the electrical socket must be easily
accessible.
The cable must not be bent or compressed.
The cable must be checked regularly and replaced
by authorised technicians only.
T
h
e
m
a
nu
f
a
c
t
u
rer
d
e
c
l
i
n
es
a
n
y
l
ia
b
i
l
it
y
s
h
o
u
l
d
t
h
ese
sa
f
et
y
m
eas
u
res
n
ot
b
e
o
b
ser
v
e
d
.
Gas
c
o
nn
e
c
tio
n
Connection to the gas network or to the gas cylinder
may be carried out using a fle
x
ible rubber or steel hose,
in accordance with current national legislation and after
making sure that the appliance is suited to the type of
gas with which it will be supplied (see the rating sticker
on the cover: if this is not the case
see below
). When
using liquid gas from a cylinder, install a pressure
regulator which complies with current national
regulations. To make connection easier, the gas supply
may be turned sideways*: reverse the position of the
hose holder with that of the cap and replace the gasket
that is supplied with the appliance.
Check that the pressure of the gas supply is consistent
with the values indicated in the Table of burner and nozzle
specifications (
see below
). This will ensure the safe
operation and durability of your appliance while maintaining
efficient energy consumption.
Gas
c
o
nn
e
c
tio
n
u
si
ng
a
f
l
e
x
i
b
l
e
r
u
bb
er
h
ose
Make sure that the hose complies with current national
legislation. The internal diameter of the hose must
measure: 8 mm for liquid gas supply; 13 mm for
methane gas supply.
Once the connection has been performed, make sure
that the hose:
Does not come into contact with any parts that
reach temperatures of over 50°C.
Is not subject to any pulling or twisting forces and
that it is not kinked or bent.
Does not come into contact with blades, sharp
corners or moving parts and that it is not
compressed.
*
Only available in certain models.

GB
1
7
Its whole length is easy to inspect so that the
condition of the hose may be checked.
Is shorter than 1500 mm.
Fits firmly into place at both ends, where it will be
fi
x
ed using clamps that comply with current
regulations.
If one or more of these conditions is not fulfilled or if
the cooker must be installed according to the
conditions listed for class 2 - subclass 1 appliances
(installed between two cupboards), the fle
x
ible steel
hose must be used instead (
see below
).
C
o
nn
e
c
ti
ng
a
f
l
e
x
i
b
l
e
j
oi
n
t
l
ess
stai
n
l
ess
stee
l
p
i
p
e
to
a
t
h
rea
d
e
d
atta
ch
m
e
n
t
Make sure that the hose and gaskets comply with
current national legislation.
To begin using the hose, remove the hose holder on
the appliance (the gas supply inlet on the appliance is
a cylindrical threaded 1/2 gas male attachment).
Perform the connection in such a way that the hose
length does not e
x
ceed a ma
x
imum of 2 metres,
making sure that the hose is not compressed and
does not come into contact with moving parts.
Ch
e
c
k
i
ng
t
h
e
ti
gh
t
n
ess
o
f
t
h
e
c
o
nn
e
c
tio
n
When the installation process is complete, check the
hose fittings for leaks using a soapy solution. Never
use a flame.
A
d
a
p
ti
n
g
to
d
i
ff
ere
n
t
ty
p
es
o
f
g
as
It is possible to adapt the appliance to a type of gas
other than the default type (this is indicated on the
rating label on the cover).
Ad
a
p
ti
ng
t
h
e
h
o
b
Replacing the nozzles for the hob burners:
1. Remove the hob grids and slide the burners off their
seats.
2. Unscrew the nozzles using a
7 mm socket spanner (
see
figure
), and replace them with
nozzles suited to the new type
of gas (
see Burner and nozzle
specifications table
).
3. Replace all the components
by following the above
instructions in reverse.
Adjusting the hob burners minimum setting:
1. Turn the tap to the minimum position.
2. Remove the knob and adjust the regulatory screw,
which is positioned inside or ne
x
t to the tap pin, until
the flame is small but steady.
If the appliance is connected to a liquid gas supply,
the regulatory screw must be fastened as tightly as
possible.
3. While the burner is alight, quickly change the position of
the knob from minimum to ma
x
imum and vice versa
several times, checking that the flame is not e
x
tinguished.
The hob burners do not require primary air adjustment.
After adjusting the appliance so it may be used with a
different type of gas, replace the old rating label with a new
one that corresponds to the new type of gas (these labels
are available from Authorised Technical Assistance
Centres).
Should the gas pressure used be different (or vary
slightly) from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet hose in
accordance with current national regulations relating to
regulators for channelled gas.

1
8
G
B
T
a
b
le
o
f
b
u
r
n
er
a
n
d
n
o
zz
le
s
p
e
c
i
f
i
c
atio
n
s
T
able
1
Liquid
Gas
Natural
Gas
D
iameter
(mm)
Thermal
Power
kW
(p.c.s.*)
By
Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nozzle
1/100
Flow*
l/h
Burner
Nominal
Reduced
(mm)
(mm)
***
**
(mm)
(mm)
Triple
Crown
(TC)
130
3.25
1.50
63
91
236
232
133
309
150
309
Semi
Fast
(Medium)(S)
75
1.90
0.4
30
70
138
136
104
181
118
181
Auxiliary
(Small)(A)
51
1.00
0.4
30
52
73
71
76
95
80
95
Supply
Pressures
Nominal
(mbar)
Minimum
(mbar)
Maximum
(mbar)
28-30
20
35
37
25
45
20
17
25
13
6,5
18
*
At
15°C
1013
mbar-dry
gas
***
Butane
P.C.S.
=
49,47
MJ/Kg
**
Propane
P.C.S.
=
50,37
MJ/Kg
Natural
P.C.S.
=
37,78
MJ/m³
S S
TC
A
C
35S
P
6
R
/
H
A
TABLE OF CHARACTERISTSICS
Dimensions
Oven HxWxD
34xx38x41
Volume
53 l
Useful
measurements
relating to the oven
compartment
width 42 cm
depth 44 cm
height 17 cm
Burners
may be adapted for use with any type of
gas shown on the data plate, which is
located inside the flap or, after the oven
compartment has been opened, on the
left-hand wall inside the oven.
Voltage and
frequency
see data plate
ENERGY LABEL
Directive 2002/40/EC on the label of
electric ovens.
Standard EN 50304
Energy consumption for Natural
convection – heating mode:
=
Traditional mode;
Declared energy consumption for
Forced convection Class – heating
mode:
K
Baking mode.
This appliance conforms to the following
European Economic Community
directives: 73/23/EEC dated 19/02/73
(Low Voltage) and subsequent
amendments - 89/336/EEC dated
03/05/89 (Electromagnetic
Compatibility) and subsequent
amendments - 93/68/EEC dated
22/07/93 and subsequent amendments.
2002/96/EEC
Оглавление
- I nst allazione
- Des c rizione dellapparecchio
- Avv io e u t i l i zz o
- Pr e c a u z io n i e c o n s i g l i
- M a n u t e n z io n e e c u r a
- A ss i st e n z a
- O p e r a t i n g I n str u c t io n s
- I n st a ll a t io n
- De s c r i p t io n o f t h e a pp l ia n c e
- S tart -u p an d u se
- Pre c a u tions an d tips
- C a r e a nd m ai n t e n a n c e
- Ð ó êîâîäñòâî ïî ýêñïëóàòàöèè
- Ó ñòàíîâêà
- Î ïè ñàí èå èçäåëèÿ
-  ê ëþ÷å í èå è ýêñ ïëó àòà öèÿ
- Ïðåä îñòî ð î æ íîñò è è ðå êî ìå í ä à öèè
- Òåõ í è÷å ñêî å î á ñ ëóæè âàí èå è óõ î ä
- ² íñò ðó ê ö ³³ ç å êñ ïëó àòà ö ³³
- Â ñòàíîâ ëå íí ÿ
- Î ïè ñ ïðèë à äó
-  ê ëþ÷å íí ÿ ³ â è êî ðè ñòàíí ÿ
- Çà ï î á ³ æ í³ ç àñî áè è ï î ð à äè
- Ä î ãëÿä i ò åõ í³ ÷ í å î á ñ ëóã îâ ó âàíí ÿ
- Návod k obsluze
- Instalace
- Popis přístroje
- Předpis pro instalaci, seřízenía montážní práce
- Uvedení spotřebičedo chodu a použití
- Bezpečnostní opatření a rady
- Údržba a čištění