AEG md 5613: Special safety instructions for this device
Special safety instructions for this device: AEG md 5613

22
English
• Donotuseitoutdoors.Keepitawayfromsourcesof
Instruction Manual
heat, direct sunlight, humidity (never dip it into any liquid)
Thank you for choosing our product. We hope you will enjoy
and sharp edges. Do not use the appliance with wet
using the appliance.
hands. If the appliance is humid or wet, unplug it immedi-
ately.
Symbols in these Instructions for Use
• Whencleaningorputtingitaway,switchofftheappli-
Important information for your safety is specially marked. It is
ance and always pull out the plug from the socket (pull
essential to comply with these instructions in order to avoid
the plug itself, not the lead) if the appliance is not being
accidents and prevent damage to the machine:
used and remove the attached accessories.
• Donot operate the machine without supervision. If you
WARNING:
leave the room you should always turn the device off.
This warns you of dangers to your health and indicates pos-
Remove the plug from the socket.
sible injury risks.
• Thedeviceandthemainsleadhavetobecheckedregu-
larly for signs of damage. If damage is found the device
CAUTION:
must not be used.
This refers to possible hazards to the machine or other
• Donottrytorepairtheapplianceonyourown.Always
objects.
contact an authorized technician. To avoid the exposure
to danger, always have faulty cable be replaced only by
NOTE:
the manufacturer, by our customer service or by qualified
This highlights tips and information.
person and with a cable of the same type.
• Useonlyoriginalspareparts.
General Safety Instructions
• Inordertoensureyourchildren’ssafety,pleasekeepall
packaging (plastic bags, boxes, polystyrene etc.) out of
Read the operating instructions carefully before putting the
their reach.
appliance into operation and keep the instructions including
WARNING!
the warranty, the receipt and, if possible, the box with the in-
ternal packing. If you give this device to other people, please
Caution! Do not allow small children to play with the
also pass on the operating instructions.
foil as there is a danger of suffocation!
• Theapplianceisdesignedexclusivelyforprivateuseand
• Paycarefulattentiontothefollowing“SpecialSafety
for the envisaged purpose. This appliance is not fit for
Instructions”.
commercial use.
Special safety instructions for this device
WARNING:
• Thisdevicecanbeusedbychildrenovertheageof8andby
persons with reduced physical, sensory or mental capabilities
or lack of experience and/or knowledge if they are supervised.
• Children may not play with the device.
• Thedevicemayonlybeusedwithcoldorlukewarmwater.
• Onlyusethedeviceforthecleaningofthemouth.
• Emptythewatercontaineraftereachapplicationtopreventan
accumulation of bacteria.

English
23
• Whenusingbraces,ndoutwhethertheusageofanoralirriga-
tor is possible. We do not assume any liability for possible dam-
ages.
• Incaseofdiseasesinthemouthandthroatarea,youshouldask
your doctor whether the use of an oral irrigator is advisable.
• Ensurethatthewatertube(connectionofdeviceandoralirriga-
tor) is not stuck or kinked.
Level I: low water pressure
Overview of the control elements
Level II: medium water pressure
1 Single jet nozzle
Level III: high water pressure
2 Water stop switch
3 Handle
Water stop switch (2)
4 Water hose
You can use this switch to momentarily interrupt the applica-
5 Water pressure regulator
tion. The shut-off is done mechanically. The pump of the
6 On/Off switch
device will continue to be in operation.
7 Unit base
Position I of the switch: Water is flowing
8 Water container
Position 0 of the switch: Water is stopping
9 Handle for opening the lid / Handle for water container
Nozzles (1)
Unpacking the Device
4 nozzles with different color markings are contained in the
1. Take the device out of its packaging.
scope of delivery. These can be assigned to different users.
2. Remove all packaging materials, such as foils, filler mate-
rial, cable brackets and cardboard packaging.
When the gums are bleeding . . .
3. Check the scope of delivery.
It is normal for a normal bleeding to occur when using the
oral irrigator the first few times. Should your gums bleed
NOTE:
continually, please consult your dentist.
There may still be some dust or production residues on
the device. We recommend that you clean the device as
Initial operation
describedunder“Cleaning”.
1. Remove the water container (8) from the unit base by the
handle. Open it with the lever (9).
Application instructions
2. Fill the water container with water. Observe the marking
Electrical connection
MAX. Close the water container. Set it back onto the unit
1. Check whether the mains voltage that you want to use
base.
matches the one of the device. You will find the informa-
3. Turn on the device with the On / Off switch (6).
tion about it on the type plate.
4. Remove the handle (3) of the unit base. Hold the opening
2. Connect the mains cable to a properly installed ground-
above a wash basin.
ed socket.
5. Switch the regulator (5) to level III.
6. Unlock the water stop switch (2) by sliding it to position I.
On / Off switch (6)
7. Let the water run directly into the wash basin to remove
possible residues. Then lock the water stop switch by slid-
Switch setting 0: The device is turned off
ing it to the position 0.
Switch setting I: The device is turned on
8. Turn off the device.
9. Briefly rinse off the nozzles under running water.
Water pressure regulator (5)
With the water pressure regulator, you can set three different
Your oralirrigator is now ready for use.
power levels.

24
English
Usage
Noise development
Before using the water jet you should clean your teeth with a
The emisssion value referred to the place of work is below
toothbrush.
70 dB (A).
1. Insert the nozzle onto the handle as far as possible. Turn
Operating noises
the nozzle so that its opening points to the water stop
The noise that you perceive during use occur by the water flow.
switch. Ensure that the nozzle is fixed firmly in position.
These noises are unavoidable due to the high performance,
2. Fill the water container with water which is hand warm.
but make no shortage represents.
Donotllitwithhotwater!
3. In order to clean the nozzles, allow water to flow through
the nozzle head (at maximum water pressure) into the
Technical Data
wash basin before and after each time the device is used.
Model: ................................................................................. MD 5613
4. Then use the water pressure regulator to select the
Power supply: ............................................................230 V~ ; 50 Hz
desired water pressure. Begin on the smallest setting, es-
Power consumption:.......................................................max. 46 W
pecially if you have problems with bleeding of the gums
Protection class: .................................................................... II (IPX 7)
or when the water jet is used by children.
Net weight: ...............................................................................1.3 kg
5. Unlock the water stop switch on the handle.
6. Lean over the wash basin. Guide the water jet along the
The right to make technical and design modifications in
gums, around the teeth.
the course of continuous product development remains
7. Lock the water stop switch after the application. Set the
reserved.
water pressure regulator to level I.
This device has been tested according to all relevant current
8. Turn off the device.
CE guidelines, such as electromagnetic compatibility and low
9. Please clean the device as described under “Cleaning
voltage directives, and has been constructed in accordance
andCare”.
with the latest safety regulations.
Cleaning and Care
WARNING:
• Pullthemainsplugfromthesocketbeforeeachclean-
ing.
• Donotimmersetheunitbaseandthemainsplugin
Disposal
water.
Meaning of the “Dustbin” Symbol
CAUTION:
Protect our environment: do not dispose of electrical equip-
• Donotuseanywirebrushorotherabrasiveobjects.
ment in the domestic waste.
• Donotuseanysharporabrasivecleaners.
Please return any electrical equipment that you will no longer
1. Pour out the remaining water from the water container.
use to the collection points provided for their disposal.
2. Pull the nozzle off the handle. Clean the nozzles under
This helps avoid the potential eff ects of incorrect dispsal on
warm running water. Dry the nozzles and place them onto
the environment and human health.
the unit base.
This will contribute to the recycling and other forms of reutili-
3. If you have used water additives, rinse the water con-
sation of electrical and electronic equipment.
tainer with clear water. Then let ca. 300 ml clear water run
through the device as described under “Initial opera-
Information concerning where the equipment can be dis-
tion”.
posed of can be obtained from your local authority.
4. Dry the handle before you place it back onto the unit
base.
5. Dry off the water container.
6. Clean the unit base with a moist towel. Then wipe it dry.
Table of contents
- Spezielle Sicherheitshinweise für dieses Gerät
- Speciale veiligheidsinstructies voor dit apparaat
- Consignes de sécurité spéciales pour cet appareil
- Indicaciones especiales para su seguridad referentes a este aparato
- Avvertenze speciali di sicurezza per questo apparecchio
- Special safety instructions for this device
- Specjalne wskazówki związane z bezpieczną obsługą tego urządzenia
- Speciális biztonsági figyelmeztetés a készülékhez
- Спеціальна інструкція з безпеки для цього приладу
- Особые указания по технике безопасности для это- го устройства
-