body and directly filling it with water, using a
common bottle or jug.
A7
Place a glass or large container under the
dispense area and touch the dispense button to
operate the unit, and touch again to stop the ap-
pliance. Allow water to run through the unit until
the reservoir has been emptied.
Do not consume the water until step A8
has been completed.
The first 3-5 litres of water dispensed may
contain some fine, black carbon particles. car
-
bon is a natural, organic material made from
coconut shell so don’t worry for your safety.
Clear water should be noticed after flushing
through 3 to 5 litres of water (2 to 3 full re-
servoirs).
A8
Repeat steps a2-a7 five times (5x): this will
completely flush the carbon from the new filter.
PRODUCT USAGE
B1
When the appliance is in standby mode the
button will be blue but when it is touched it will turn
green and water will be dispensed.
If the button is not touched within 2 mi-
nutes of being activated then it will au-
tomatically stop the flow of water and turn the
pump off.
B2
Touch to STOP dispensing water. When you
touch the button to stop water being dispensed
the button will change colour from green to blue.
After one minute the product is in a
stand-by mode, it goes in an energy sa-
ving mode as the UV lamp is off; when the pro-
duct is in this condition, there will be a 2 se-
cond delay before the water is dispensed after
the dispense button is touched so to activate
the UV lamp and purify the water.
Your product has been designed and in-
ternationally certified to the highest
standards of water purification, and guarante
-
es at all times, to dispense the best water qua-
lity. The self monitoring system will warn you
of any potential risks, by way of 3 possible
alarms.
B3
Once the Filter has is at 11 months after its
first usage, the Filter icon will flash as a reminder,
and continue to flash until the filter has been re
-
placed as per B4 below. During this time, your
machine will continue to dispense water, until B4
below has been reached.
B4
After a 12 month period, both the UV Bulb
and Filter must be replaced to ensure optimal wa-
ter purification. Both the UV Icon and Filter Icon
will alarm 20 times and flash alternately. When
this occurs, no water will be dispensed, until the
Filter and UV Bulb have both been replaced and
the machine reset (to do this you will need to fol-
low steps C1 to C17).
MAINTENANCE
This product is a high performance water machi-
ne, keeping it in good working order will provide
the reassurance of truly great drinking water.
The uv bulb and filter must be replaced
every 12 months to ensure that your ap-
pliance is dispensing the highest quality drin-
king water.
For the correct and effective appliance
working, use only hotpoint-ariston
[hotpoint] replacement kit (read service sec-
tion)
Unplug the Appliance from the mains
before replacing the UV lamp or filter.
It’s recommended to do next steps on a wa-
shable surface. After this procedure it’s re-
commended that you clean the surface with a
home-use disinfecting product.
C1
Remove the water reservoir from the main
body of the appliance.
C2
Remove the two screws that hold the lid in
place using the screwdriver you can find in the
box.
C3
Remove the lid from the unit by slightly
pushing it back and then lifting it up.
C4
Disconnect the UV lamp connector by hol-
ding it and pressing in the clip on the connector

hotpoint.
eu
14 en
C10
Remove the filter cartridge from the head by
pulling it out as per illustration.
The filter cartridge can be disposed of
with normal household waste.
Before installing the new filtering car
-
tridge, wash the plastic filter body with a
washing up liquid and rinse thoroughly.
C11
Remove the new filter cartridge from the
packaging and fit it by firmly pushing it into the fil
-
ter head, making sure it is firmly and securely fit
-
ted. Make sure the new filter you are fitting comes
in a sealed bag for hygienic purposes.
C12
Screw the filter head and the filter body to
-
gether, making sure it is firmly tightened.
C13
Fit the filter assembly with the back into the
appliance as follows:
1.
Insert the filter assembly back into its cradle,
aligning the two male spigots with the female
holes in the cradle. Push firmly until the filter
sits snugly and is flush inside the cradle and
with the cradle top surface.
2.
Lock the filter by closing the locking lever un
-
til it ‘clicks’ into place
3.
Rotate the red rotating lever back into the
LOCK position.
C14
Re-fit the lid, making sure the front is atta
-
ched first. If the lid is not fitted correctly the unit
will not switch on.
Fit the lid making sure the front is
pushed in place first and then push the
back end with the screws down to give a snug
fit.
C15
Re-fit the two screws that hold the lid down
using the screwdriver.
The screws should be hand tightened,
do not over tighten.
C16
Insert the plug into the mains socket and
press and hold the dispense button for 10 secon-
ds until you hear a beep as this will reset the filter
timer.
and pulling it up.
C5
To remove the UV lamp firmly pull it up and
out. Do not pull the lamp out at an angle as it may
break or damage the internal parts of the applian
-
ce.
The UV lamp must be disposed of cor-
rectly and must not be disposed of with
normal household waste.
C6
Insert the new UV lamp while holding the
white end caps only. Insert the UV lamp as shown
in the illustration and push it all the way down until
it cannot go any further.
Do not use force when removing and in-
serting the UV lamp as you may damage
internal parts. Do not touch the UV lamp glass
surface with your fingers as this will affect the
performance of the UV lamp.
C7
Re-connect the UV lamp connector making
sure the connectors are lined up correctly as they
will only fit together when correctly aligned.
Pay attention not to wet the UV lamp
connector; in case of water drops on UV
lamp connectors, do not reconnect to power
mains before drying completely.
Wear disposable gloves during the ope-
rations of filter removal hereafter descri
-
bed to avoid the direct contact with wet parts.
C8
To remove the Filter, do the following:
1. Rotate the red rotating lever so that it is pa-
rallel with the side panel.
2.
Insert your finger into the round hole of the
lever, and pull the lever up to the vertical
position.
3. Pull the lever straight up to remove the Filter
assembly (some slight force may be requi-
red).
C9
Unscrew the filter body from the filter head
by turning the base in a anti clockwise direction as
per the illustration.
Be careful as the filter body will contain
water.
Оглавление
- PARTI E CARATTERISTICHE
- USO DEL PRODOTTO
- PULIZIA
- INDIVIDUAZIONE DEI GUASTI
- ASSISTENZA
- Welcome to pure water world, with a new Hotpoint-Ariston WATER MACHINE !
- PARTS AND FEATURES
- PRODUCT USAGE
- CLEANING
- CERTIFICATION
- Bienvenue dans le monde de l’eau pure avec la nouvelle WATER MACHINE de Hotpoint-Ariston!
- PIÈCES ET CARACTÉRISTIQUES
- UTILISATION DU PRODUIT
- ENTREPOSAGE
- CERTIFICATION
- MISE AU REBUT CORRECTEDU PRODUIT
- Добро пожаловать в мир чистой воды с новым электрическим очистителем воды Hotpoint-Ariston!
- КОМПОНЕНТЫ ИХАРАКТЕРИСТИКИ
- ЭКСПЛУАТАЦИЯ ИЗДЕЛИЯ
- ТЕХОБСЛУЖИВАНИЕ
- ЧИСТКА
- ВЫЯВЛЕНИЕ НЕИСПРАВНОСТЕЙ
- СЕРТИФИКАЦИЯ
- Hotpoint-Ariston’un SU ARITMA CiHAZI ile suyunuzun lezzetini yeniden keşfedin!
- CIHAZ TANIMI VEÖZELLİKLERİ
- KULLANIM TALIMATLARI I
- CIHAZIN BAKIMI
- TEMİZLİK
- SORUN GİDERME
- ÜRÜNÜN DOĞRU ŞEKİLDEİMHA EDİLMESİ
- Bem-vindo ao mundo da água pura, com a nova WATER MACHINE de Hotpoint-Ariston!
- PEÇAS E CARACTERÍSTICAS
- USO DO PRODUTO
- LIMPEZA
- PROBLEMAS
- ASSISTÊNCIA
- Ласкаво просимо у світ чистої води з новим ВОДООЧИСНИКОМ Hotpoint-Ariston!
- КОМПОНЕНТИ ТАХАРАКТЕРИСТИКИ
- ЕКСПЛУАТАЦІЯ ВИРОБУ
- ТЕХОБСЛУГОВУВАННЯ
- ЧИЩЕННЯ
- ВИЯВЛЕННЯНЕСПРАВНОСТЕЙ
- ДОПОМОГА
- Жаңа Hotpoint-Ariston құрылғысымен таза су әлеміне қош келдіңіз СУ ТАЗАРТҚЫШЫ !
- БӨЛШЕКТЕР МЕНМҮМКІНДІКТЕР
- ӨНІМДІ ҚОЛДАНУ
- ТАЗАЛАУ
- АҚАУЛЫҚТАРДЫ ЖОЮ
- ҚЫЗМЕТ КӨРСЕТУ