Hotpoint-Ariston CE 6V M3 R/HA: I n s t alla t ion

I n s t alla t ion: Hotpoint-Ariston CE 6V M3 R/HA

background image

14

G

B

B

efore operating your new appliance please read

this  instruction  boo

k

let  carefully.  It  contains

important  information  concerning  the  safe  installation

and operation of the appliance.

 Please 

k

eep these operating instructions for future

reference. Ma

k

e sure that the instructions are 

k

ept

with the appliance if it is sold, given away or moved.

 The appliance must be installed by a qualified

professional in accordance with the instructions

provided.

 Any necessary adjustment or maintenance must be

performed after the coo

k

er has been disconnected

from  the  electricity  supply.

P

o

s

itionin

an

le

v

ellin

g

 It is possible to install the appliance alongside

cupboards whose height does not e

x

ceed that of the

hob  surface.

 Ma

k

e sure that the wall in contact with the bac

k

 of

the appliance is made from a non-flammable, heat-

resistant material (T 90°C).

To install the appliance correctly:

• Place it in the 

k

itchen, the dining room or the bed-

sit (not in the bathroom).

• If the top of the hob is higher than the cupboards,

the appliance must be installed at least 600 mm

away from them.

• If the coo

k

er is

installed underneath a

wall cabinet, there must

be  a  minimum  distance

of 420 mm between

this cabinet and the top

of the hob.

This  distance  should

be increased to 700

mm if the wall cabinets

are flammable (

see figure

).

•

D

o not position blinds behind the coo

k

er or less

than 200 mm away from its sides.

• Any hoods must be installed according to the

instructions listed in the relevant operating

manual.

L

e

v

ellin

g

If it is necessary to level the

appliance, screw the

adjustable feet into the places

provided on each corner of the

base of the coo

k

er (

see

figure

).

The legs* fit into the slots on

the underside of the base of

the  coo

k

er.

E

le

c

t

r

i

c

al

 c

onne

c

tion

F

ittin

t

h

e

 p

o

w

e

r

s

upp

l

y c

a

b

le

To open the terminal board:

• Insert a screwdriver into the side tabs of the

terminal  board  cover.

• Pull the cover to

open  it.

To install the cable, follow the instructions below:

• Loosen the cable clamp screw and the wire

contact  screws.

 The jumpers are pre-set at the Factory for 230 V

single-phase connection (

see  figure

).

• To carry out the electrical connections as shown in

the figures, use the two jumpers inside the bo

x

(

see figure

 - labelled “P”).

I n s t alla t ion

HOOD

420

Min.

min. 

650

 mm. with hood

min. 

700

 mm. without hood

mm.

600

Min.

mm.

420

Min.

mm.

*

O

n

l

y

a

v

a

il

a

ble

i

n

ce

r

t

a

i

n

mo

dels.

N

L2

L1

L3

P

N

L

230V 1N~

H07RN-F 3x4 CEI-UNEL 35364

1

3

2

4

5

background image

G

B

1

5

N

L3

L1

L2

400V 3N~

H05RR-F 5x2.5 CEI-UNEL 35363

1

3

2

4

5

N

L2 L1

400V 2N~

H05RR-F 4x2.5 CEI-UNEL 35363

1

3

2

4

5

• Secure the power supply cable by fastening the

cable clamp screw then put the cover bac

k

 on.

C

onnectin

g

the

suppl

y

ca

b

le

to

the

electricit

y

mains

Install a standardised plug corresponding to the

load indicated on the appliance data plate (

see

Technical data table

).

The appliance must be directly connected to the

mains using an omnipolar switch with a minimum

contact opening of 3 mm installed between the

appliance and the mains.  The switch must be

suitable for the charge indicated and must comply

with current electrical regulations (the earthing wire

must not be interrupted by the switch). The supply

cable must be positioned so that it does not come

into contact with temperatures higher than 50°C at

any  point.

B

efore connecting the appliance to the power

supply,  ma

k

e  sure  that:

• The appliance is earthed and the plug is compliant

with the law.

• The soc

k

et can withstand the ma

x

imum power of

the appliance, which is indicated by the data

plate.

• The voltage is in the range between the values

indicated on the data plate.

• The soc

k

et is compatible with the plug of the

appliance. If the soc

k

et is incompatible with the

plug, as

k

 an authorised technician to replace it.

D

o not use e

x

tension cords or multiple soc

k

ets.

 Once the appliance has been installed, the power

supply cable and the electrical soc

k

et must be

easily  accessible.

 The cable must not be bent or compressed.

 The cable must be chec

k

ed regularly and replaced

by  authorised  technicians  only.

T

he

manu

f

acturer

d

eclines

an

y

lia

b

ilit

y

shoul

d

these

sa

f

et

y

measures

not

 b

e

o

b

ser

v

e

d

.

TABLE OF CHARACTERISTICS

Oven dimensions 

(HxWxD)

32x43.5x40 cm 

Volume

56 l 

Useful 

measurements 

relating to the oven 

compartment

width 42 cm 

depth 44 cm 

height 8.5 cm 

Voltage and 

frequency

see data plate 

Ceramic hob 

Front Left 

Back Left 

Back Right 

Front Right 

Max. ceramic hob 

consumption 

1700 W 

1200 W 

2100 W 

1200 W 

6200 W 

ENERGY LABEL

Directive 2002/40/EC on the 

label of electric ovens.  

Standard EN 50304 

Natural convection energy 

consumption 

heating mode: 

Traditional mode 

Declared forced convection 

energy consumption 

heating mode: 

Multilevel. 

This appliance conforms to the 

following European Economic 

Community directives: 

73/23/EEC dated 19/02/73 

(Low Voltage) and subsequent 

amendments - 89/336/EEC 

dated 03/05/89 

(Electromagnetic Compatibility) 

and subsequent amendments - 

93/68/EEC dated 22/07/93 and 

subsequent amendments. 

2002/96/EEC