Hotpoint-Ariston C 34S M5 R/HA: I n s tallation
I n s tallation: Hotpoint-Ariston C 34S M5 R/HA

15
GB
A
I n s tallation
Ad
j
acent
room
Room
requiring
ventilation
A
B
Ventilation
opening
for
comburent
air
Increase
in
the
gap
between
the
door
and
the
flooring
Fumes
channelled
straight
outside
Fumes
channelled
through
a
chimney
or
a
branched
flue
system
(reserved
for
cooking
appliances)
Before operating
y
our new appliance please read
this instruction booklet carefull
y
. It contains
important information concerning the safe installation
and operation of the appliance.
Please keep these operating instructions for future
reference. Make sure that the instructions are kept
with the appliance if it is sold, given awa
y
or moved.
The appliance must be installed b
y
a qualified
professional according to the instructions provided.
An
y
necessar
y
ad
j
ustment or maintenance must be
performed after the cooker has been disconnected
from the electricit
y
suppl
y
.
R
oo
m
v
entilation
The appliance ma
y
onl
y
be installed in permanentl
y
-
ventilated rooms, according to current national
legislation. The room in which the appliance is
installed must be ventilated adequatel
y
so as to
provide as much air as is needed b
y
the normal gas
combustion process (the flow of air must not be
lower than 2 m
3
/h per kW of installed power).
The air inlets, protected b
y
grilles, should have a
duct with an inner cross section of at least 100 cm
2
and should be positioned so that the
y
are not liable
to even partial obstruction (
see figure A
).
These inlets should be enlarged b
y
100% - with a
minimum of 200 cm
2
- whenever the surface of the
hob is not equipped with a flame failure safet
y
device. When the flow of air is provided in an
indirect manner from ad
j
acent rooms (
see figure B
),
provided that these are not communal parts of a
building, areas with increased fire hazards or
bedrooms, the inlets should be fitted with a
ventilation duct leading outside as described above.
After prolonged use of the appliance, it is
advisable to open a window or increase the speed of
an
y
fans used.
D
i
s
p
o
s
in
g
o
f
c
o
m
b
us
tion
f
u
m
e
s
The disposal of combustion fumes should be
guaranteed using a hood connected to a safe and
efficient natural suction chimne
y
, or using an electric
fan that begins to operate automaticall
y
ever
y
time
the appliance is switched on (
see figure
).
The liquefied petroleum gases are heavier than air
and collect b
y
the floor, therefore all rooms
containing LPG c
y
linders must have openings
leading outside so that an
y
leaked gas can escape
easil
y
.
LPG c
y
linders, therefore, whether partiall
y
or
completel
y
full, must not be installed or stored in
rooms or storage areas that are below ground level
(cellars, etc.). Onl
y
the c
y
linder being used should
be stored in the room; this should also be kept well
awa
y
from sources of heat (ovens, chimne
y
s,
stoves) that ma
y
cause the temperature of the
c
y
linder to rise above 50°C.
P
os
iti
on
i
n
g
a
n
d
le
v
ell
i
n
g
It is possible to install the appliance alongside
cupboards whose height does not e
x
ceed that of the
hob surface.
Make sure that the wall in contact with the back of
the appliance is made from a non-flammable, heat-
resistant material (T 90°C).
To install the appliance correctl
y
:
Place it in the kitchen, the dining room or the bed-
sit (not in the bathroom).
If the top of the hob is higher than the cupboards,
the appliance must be installed at least 200 mm
awa
y
from them.
If the cooker is installed underneath a wall cabinet,
there must be a minimum distance of 420 mm
between this cabinet and the top of the hob.
This distance should be increased to 700 mm if
the wall cabinets are flammable (
see figure
).

16
GB
HOOD
420
Min.
min.
650
mm. with hood
min.
700
mm. without hood
mm.
600
Min.
mm.
420
Min.
mm.
* Onl
y
available in certain models
Do not position
blinds behind the
cooker or less than 200
mm awa
y
from its
sides.
An
y
hoods must be
installed according to
the instructions listed in
the relevant operating
manual.
L
e
v
ellin
g
If it is necessar
y
to level the
appliance, screw the
ad
j
ustable feet into the places
provided on each corner of the
base of the cooker (
see
figure
).
The legs* fit into the slots on
the underside of the base of
the cooker.
E
le
c
t
r
i
c
a
l
c
onne
c
ti
ons
Install a standardised plug corresponding to the
load indicated on the appliance data plate (
see
Technical data table
).
The appliance must be directl
y
connected to the mains
using an omnipolar circuit-breaker with a minimum
contact opening of 3 mm installed between the
appliance and the mains. The circuit-breaker must be
suitable for the charge indicated and must compl
y
with
NFC 15-100 regulations (the earthing wire must not be
interrupted b
y
the circuit-breaker). The suppl
y
cable
must be positioned so that it does not come into
contact with temperatures higher than 50°C at an
y
point.
Before connecting the appliance to the power
suppl
y
, make sure that:
The appliance is earthed and the plug is compliant
with the law.
The socket can withstand the ma
x
imum power of
the appliance, which is indicated b
y
the data plate.
The voltage is in the range between the values
indicated on the data plate.
The socket is compatible with the plug of the
appliance. If the socket is incompatible with the
plug, ask an authorised technician to replace it.
Do not use e
x
tension cords or multiple sockets.
Once the appliance has been installed, the power
suppl
y
cable and the electrical socket must be
easil
y
accessible.
The cable must not be bent or compressed.
The cable must be checked regularl
y
and replaced
b
y
authorised technicians onl
y
.
T
h
e
m
an
u
f
a
c
t
u
rer
d
e
c
line
s
an
y
lia
b
ilit
y
s
h
o
u
l
d
t
h
e
s
e
s
a
f
et
y
m
ea
su
re
s
not
b
e
o
b
s
er
v
e
d
.
G
a
s
c
onne
c
tion
Connection to the gas network or to the gas c
y
linder
ma
y
be carried out using a fle
x
ible rubber or steel
hose, in accordance with current national legislation
and after making sure that the appliance is suited to
the t
y
pe of gas with which it will be supplied (see
the rating sticker on the cover: if this is not the case
see below
). When using liquid gas from a c
y
linder,
install a pressure regulator which complies with
current national regulations. To make connection
easier, the gas suppl
y
ma
y
be turned sidewa
y
s*:
reverse the position of the hose holder with that of
the cap and replace the gasket that is supplied with
the appliance.
Check that the pressure of the gas suppl
y
is consistent
with the values indicated in the Table of burner and
nozzle specifications (
see below
). This will ensure the
safe operation and durabilit
y
of
y
our appliance while
maintaining efficient energ
y
consumption.
G
a
s
c
onne
c
tion
us
in
g
a
f
le
x
i
b
le
r
u
bb
er
h
o
s
e
Make sure that the hose complies with current
national legislation. The internal diameter of the hose
must measure: 8 mm for liquid gas suppl
y
; 13 mm
for methane gas suppl
y
.
Once the connection has been performed, make
sure that the hose:
Does not come into contact with an
y
parts that
reach temperatures of over 50°C.
Is not sub
j
ect to an
y
pulling or twisting forces and
that it is not kinked or bent.
Does not come into contact with blades, sharp
corners or moving parts and that it is not
compressed.
Is eas
y
to inspect along its whole length so that
its condition ma
y
be checked.
Is shorter than 1500 mm.
Fits firml
y
into place at both ends, where it will be
fi
x
ed using clamps that compl
y
with current
regulations.

17
GB
If one or more of these conditions is not fulfilled or
if the cooker must be installed according to the
conditions listed for class 2 - subclass 1 appliances
(installed between two cupboards), the fle
x
ible steel
hose must be used instead (
see below
).
C
onne
c
tin
g
a
f
le
x
i
b
le
j
ointle
ss
s
tainle
ss
s
teel
p
i
p
e
to
a
t
h
rea
d
e
d
atta
c
hm
ent
Make sure that the hose and gaskets compl
y
with
current national legislation.
To begin using the hose, remove the hose holder on
the appliance (the gas suppl
y
inlet on the appliance
is a c
y
lindrical threaded 1/2 gas male attachment).
Perform the connection in such a wa
y
that the hose
length does not e
x
ceed a ma
x
imum of 2 metres,
making sure that the hose is not compressed and
does not come into contact with moving parts.
C
h
e
c
k
in
g
t
h
e
c
onne
c
tion
f
or
lea
k
s
When the installation process is complete, check the
hose fittings for leaks using a soap
y
solution. Never
use a flame.
A
d
a
p
ti
n
g
t
o
d
i
ff
e
r
en
t
t
y
p
es
o
f
g
a
s
It is possible to adapt the appliance to a t
y
pe of gas
other than the default t
y
pe (this is indicated on the
rating label on the cover).
A
d
a
p
tin
g
t
h
e
h
o
b
Replacing the nozzles for the hob burners:
1. Remove the hob grids and slide the burners off
their seats.
2. Unscrew the nozzles using
a 7 mm socket spanner (
see
figure
), and replace them with
nozzles suited to the new t
y
pe
of gas (
see Burner and nozzle
specifications table
).
3. Replace all the components
b
y
following the above instructions in reverse.
Ad
j
usting the hob burners minimum setting:
1. Turn the tap to the minimum position.
2. Remove the knob and ad
j
ust the regulator
y
screw, which is positioned inside or ne
x
t to the tap
pin, until the flame is small but stead
y
.
If the appliance is connected to a liquid gas
suppl
y
, the regulator
y
screw must be fastened as
tightl
y
as possible.
3. While the burner is alight, quickl
y
change the position
of the knob from minimum to ma
x
imum and vice versa
several times, checking that the flame is not
e
x
tinguished.
The hob burners do not require primar
y
air ad
j
ustment.
After ad
j
usting the appliance so it ma
y
be used with a
different t
y
pe of gas, replace the old rating label with a
new one that corresponds to the new t
y
pe of gas (these
labels are available from Authorised Technical Assistance
Centres).
! Should the gas pressure used be different (or var
y
slightl
y
) from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet hose in
accordance with current national regulations relating to
regulators for channelled gas.

1
8
GB
C
3
4
S
M
5
R
/HA
T
able
o
f
b
ur
ne
r
an
d
nozzle
s
p
e
c
i
f
i
c
ations
S S
R
A
T
able
1
Liquid
Gas
Natural
Gas
D
iameter
(mm)
Thermal
Power
kW
(p.c.s.*)
By
Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nozzle
1/100
Flow*
l/h
Burner
Nominal
Reduced
(mm)
(mm)
***
**
(mm)
(mm)
Fast
(Large)(R)
100
3.00
0.7
41
87
218
214
128
286
143
286
Semi
Fast
(Medium)(S)
75
1.90
0.4
30
70
138
136
104
181
118
181
Auxiliary
(Small)(A)
51
1.00
0.4
30
52
73
71
76
95
80
95
Supply
Pressures
Nominal
(mbar)
Minimum
(mbar)
Maximum
(mbar)
28-30
20
35
37
25
45
20
17
25
13
6,5
18
*
At
15°C
1013
mbar-dry
gas
***
Butane
P.C.S.
=
49,47
MJ/Kg
**
Propane
P.C.S.
=
50,37
MJ/Kg
Natural
P.C.S.
=
37,78
MJ/m³
TECHNICAL DATA
Oven dimensions
(HxWxD)
34x38x41 cm
Volume
53 l
Useful
measurements
relating to the
oven
compartment
width 42 cm
depth 44 cm
height 17 cm
Power supply
voltage and
frequency
see data plate
Burners
may be adapted for use with any
type of gas shown on the data
plate, which is located inside the
flap or, after the oven compartment
has been opened, on the left-hand
wall inside the oven.
ENERGY LABEL
Directive 2002/40/EC on the label
of electric ovens. Standard EN
50304
Energy consumption for Natural
convection – heating mode:
=
=
Static
Declared energy consumption for
Forced convection Class – heating
mode:
>
>
Fan-assisted
EC Directives: 73/23/EEC dated
19/02/73 (Low Voltage) and
subsequent amendments -
89/336/EEC dated 03/05/89
(Electromagnetic Compatibility) and
subsequent amendments -
90/369/EEC dated 29/06/90 (Gas)
and subsequent amendments -
93/68/EEC dated 22/07/93 and
subsequent amendments -
2002/96/EC.
Оглавление
- Installazione
- D es c rizione d ell a pp are cch io
- A vv io e u tilizzo
- P re c a u z ioni e c on s i g li
- M an u ten z ione e cu ra
- A ss i s ten z a
- Op eratin g I n s tr uc tion s
- I n s tallation
- D e s c ri p tion o f t h e a pp lian c e
- S ta r t- u p an d u se
- P r e c a u ti ons a n d ti p s
- Care an d maintenan c e
- Ð óêîâîäñòâî ïî ýêñïëóàòàöèè
- Óñòàíîâêà
- Î ïèñàíè å èçä å ëèÿ
- Â êëþ÷ å íè å è ý êñïëóàòàöèÿ
- Ïð å äîñòîðîæíîñòè è ð å êîì å íäàöèè
- Ò å õíè÷ å ñêî å îáñëóæèâàíè å è óõîä