Xylem MAXIBOX PLUS: 7. 7.7. 7. Start StartStart Start----up upupup

7. 7.7. 7. Start StartStart Start----up upupup: Xylem MAXIBOX PLUS

background image

en 

en 

en 

en     

18 

6.5

6.5

6.5

6.5

Float switches

Float switches

Float switches

Float switches    

There are 2 float switches, one for starting and the other for the alarm. Fix the floats to the relative hooks inside the tank. Adjust the 

level of the starting float switch to the height of the electric pump lifting handle and adjust the alarm float switch 50 cm higher. 

6.6

6.6

6.6

6.6

Assembling the 

Assembling the 

Assembling the 

Assembling the electric pumps

electric pumps

electric pumps

electric pumps    

Consult the installation instructions supplied with the electric pumps. Check the impellers turn in the right direction before installing 

the electric pumps. 

Before installing the electric pumps, remove any foreign bodies at the bottom of the tank.

Connect the electric pumps to the slide kit adaptors. Install the electric pumps in the tank. 

6.7

6.7

6.7

6.7

Electrical connections

Electrical connections

Electrical connections

Electrical connections    

Electrical connections may only be performed by a qualified installer in compliance with current regulations.

    

Make sure that the type of mains power network, voltage and frequency are compatible with the ratings of 

the station components shown on the respective rating plates. Provide suitable short circuit protection on 

the supply line. 

Before making electrical connections, read this operating manual, that of the station, of the electric pumps, 

of  the  electrical  panel,  where  applicable,  and  of  the  other  station  components,  the  instructions  and  any 

electrical diagrams.

Before proceeding with any operations, make sure that all the connections (even those that are  potential-

free) are voltage-free.

Unless otherwise specified in local bylaws, the supply line must be fitted with: 

a short circuit protection device. 

a  high  sensitivity  residual  current  circuit  breaker  (30  mA)  for  additional  protection  from  electrocution  in  case  of  inefficient 

grounding. 

a general switch with a contact aperture of at least 3 mm. 

Fix the cables making sure they do not curve too tightly. Make sure the cables cannot be caught up in the electric pumps. Make sure 

the liquid cannot enter the cables through capillarity. Thread the cables of the electric pumps and float switches through the relative 

cable grommets and connect them to the electric panel. 

Ground the system in compliance with current regulations. Connect the earth cable, if fitted, to the guide bar support and to the 

crosspiece in the tank. 

The inside of the tank is damp. Fit suitable electrical safety devices. Use suitably insulated joints. 

Connect to the mains power supply. 

6.8

6.8

6.8

6.8

Extension

Extension

Extension

Extension    

Screw the extension onto the upper part of the tank instead of the cover. Screw the cover onto the top of the extension. Up to 2 

extensions may be installed. Consult section 12.8. 

6.9

6.9

6.9

6.9

Cover gasket

Cover gasket

Cover gasket

Cover gasket    

The cover gasket comprises a rectangular piece of mousse rubber. Glue the gasket to the bottom of the cover. When the cover is 

screwed into place, the tank becomes airtight. Turn the cover at least twice for a perfect seal. Consult section 12.9. 

6.10

6.10

6.10

6.10

Mounting the cover

Mounting the cover

Mounting the cover

Mounting the cover    

Screw the cover into its seat and tighten. Fit a lock to prevent unauthorised opening. 

6.10.1

6.10.1

6.10.1

6.10.1

Mounting the cover lock

Mounting the cover lock

Mounting the cover lock

Mounting the cover lock    

Consult section 12.10. Make a 21 mm diameter hole in the centre of the recessed cylindrical area of the cover. Insert the cylindrical 

upper part of the lock (1) into the above hole (the triangular lock insert must be on the outside of the cover). Screw the nut (2) to 

the lock thread. Insert the metal lock tongue (3) into the square end of the lock, insert the screw and tighten to keep the tongue in 

position. Use the supplied wrench (5) to turn the moving part of the lock so that the tongue does not slip out of the cover. Screw 

the  cover  onto  the  tank  (or  extension)  and  turn  the  wrench  to  lock  the  cover.  Remove  the  wrench  and  then  insert  the  supplied 

protective cover to prevent dirt from entering. 

7. 7. 7. 7. Start Start Start Start----up up up up    

    

    

       

       

       

       Information for installers Information for installers Information for installers Information for installers    

    

    

Before start-up, read this operating manual, that of the station, of the electric pumps, of the electrical panel 

(where applicable) and of the other station components. Keep the manuals with care.

Start-up operations may only be performed by expert and qualified staff in observance of local regulations.

Always refer to current local and/or national regulations, laws and standards. 

It is best to call in the Lowara Assistance Service to start up the system. 