Xylem MAXIBOX PLUS: 8. 8.8. 8. Maintenance, service and spare parts Maintenance, service and spare partsMaintenance, service and spare parts Maintenance, service and spare parts

8. 8.8. 8. Maintenance, service and spare parts Maintenance, service and spare partsMaintenance, service and spare parts Maintenance, service and spare parts: Xylem MAXIBOX PLUS

background image

en

en

en

en    

19 

7.1

7.1

7.1

7.1

Initial start

Initial start

Initial start

Initial start----up

up

up

up    

Before starting the station and the electric pumps, check that there are no residues or other materials in the 

system and tank that can prevent correct operation.

    

In this phase, leave the check valve on the inlet piping closed and fill the lifting station with clean water. Open the check valves on 

the  outlet  piping,  check  the  piping  is  perfectly  watertight  and  make  sure  the  electric  pumps  work  correctly.  Also  make  sure  the 

electric pumps are primed. 

Open the check valve on the inlet piping and make sure the station works correctly. 

The  flow  of  liquid  from  the  various  users  must  not  prevent  the  float  switches  in  the  tank  from  operating 

correctly.

    

For three-phase electric pumps, check the correct direction of rotation of the impellers. Also check the electric pump manual. Make 

sure that the cut-in levels of the float switches are correct. If necessary adjust them according to effective system requirements.  

During operation, make sure the electric pumps cannot be unprimed. Make sure that the number of hourly start-ups is compatible 

with the characteristics of the system components. Check the system operates correctly and put it into service. 

After starting the station and making sure it works correctly, close the tank cover and screw it into its seat. If necessary, secure the 

cover to prevent unauthorised opening (see section 6.10.1). 

8. 8. 8. 8. Maintenance, service and spare parts Maintenance, service and spare parts Maintenance, service and spare parts Maintenance, service and spare parts    

    

    

    

     Information for maintenance personnel  Information for maintenance personnel  Information for maintenance personnel  Information for maintenance personnel    

Observe the following directions when performing maintenance on the product. 

    

    

    

    

Before proceeding with any maintenance operations, make sure that all the connections (even those that are  

potential-free) are voltage-free.

    

    

Maintenance operations must be performed by skilled and qualified personnel only. 

Use suitable equipment and protection devices. Observe all accident prevention regulations. Lift and handle 

the stations and electric pumps with care using suitable lifting equipment. 

Take care as the liquid may be hot.

    

    

Read  this  operating  manual,  that  of  the  station,  of  the  electric  pumps,  of  the  electrical  panel  (where 

applicable) and of the other station components.

Always refer to current local and/or national regulations, laws and standards. 

8.1

8.1

8.1

8.1

Routine maintenance

Routine maintenance

Routine maintenance

Routine maintenance    

Periodically check the inside of the tank by opening the cover. Clean the tank at least once a year, especially around the areas where 

the float switches are located. 

Make sure the tank is airtight. Lift the electric pumps and check that the fittings with the feet connected to the delivery piping are in 

good condition. Make sure no rusting has occurred. Replace the components if necessary. Close and lock the cover before leaving 

the tank area. 

Remove the electric pumps by attaching a rope or chain to the handles. 

    

    

8.2

8.2

8.2

8.2

Spare parts

Spare parts

Spare parts

Spare parts    

Always  specify  the  identification  number  of  the  tank  and  the  relative  code  when  requesting  technical 

information or spare parts from our Sales and Service Department.

    

    

Use  only  original  spare  parts  to  replace  any  components.  The  use  of  unsuitable  spare  parts  may  cause 

malfunctions, damage and injuries and will invalidate the warranty.

9. 9. 9. 9. Troubleshootin Troubleshootin Troubleshootin Troubleshooting                                 g                                 g                                 g                                             

         

         

                              

                     

                     

                        

   

   

   Information for users and maintenance personnel Information for users and maintenance personnel Information for users and maintenance personnel Information for users and maintenance personnel    

    

Follow the instructions in the operating manual of the station, of the electric pumps, of the electrical panel 

(where applicable) and of the other station components.

For further information, consult section 7. 

10. 10. 10. 10. Disposal                                                      Disposal                                                      Disposal                                                      Disposal                                                                            

                   

                   

                           IIIInformation for installation and maintenance personnel nformation for installation and maintenance personnel nformation for installation and maintenance personnel nformation for installation and maintenance personnel    

    

    

    

    

Observe current legislation and local bylaws governing sorted waste disposal. 

11. 11. 11. 11. Warranty Warranty Warranty Warranty    

Consult the contract of sale for further information.

WARNING 