Xylem MAXIBOX PLUS: 1. 1.1. 1. General information General informationGeneral information General information

1. 1.1. 1. General information General informationGeneral information General information: Xylem MAXIBOX PLUS

background image

English

English

English

English    

en

en

en

en                                                                                                                                                                                    

                                                                                                                                                                                    

                                                                                                                                                                                    

                                                                                                                                                                                    

15 

1. 1. 1. 1. General information General information General information General information    

    

The  purpose  of  this  manual  is  to  provide  the  necessary  information  for  proper  installation,  operation  and  maintenance  of  the 

MAXIBOX PLUS series tanks for lifting stations. The contents of this manual concern the standard product, as described in the sale 

documents.  Special  versions  may  be  supplied  with  supplementary  instructions  leaflets.  Please  refer  to  the  sale  contract  for  any 

modifications or special version characteristics. Always specify the exact type of tank and relative code when requesting our Sales and 

Service Department for technical information or spare parts. For any instructions, situations and events not covered in this manual or 

in the sales documentation, please contact the nearest Technical Assistance Centre. 

Read this manual before installing and using the product. 

Improper use may cause personal injury and/or damage to property, and invalidate the warranty. 

Refer  to  the  specific  manuals  for  information  concerning  the  station,  electric  pumps,  any  electrical  panels 

and the other station components.

2. 2. 2. 2. Product description  Product description  Product description  Product description     

       

       

       

       Information for installers and users Information for installers and users Information for installers and users Information for installers and users    

The Maxibox Plus range comprises tanks for lifting stations designed to pump water from buildings or land below the level of the 

sewage network. They comprise a tank, relative internal piping and lifting kit. 

The tank must be installed buried outside buildings. The Maxibox Plus range of tanks comply with EN 12050-1 Annex Z. 

3. 3. 3. 3. Safety information Safety information Safety information Safety information    

       

       

       

       Information for installers and users Information for installers and users Information for installers and users Information for installers and users    

Observe the following rules to the letter to reduce the risks relative to the installation, maintenance and operation of the tank. 

Before  working  on  the  tank,  make  sure  that  all  the  connections  (even  those  that  are  potential-free)  are 

voltage-free.

Work on the tank must be performed by skilled and qualified personnel only. Use suitable equipment and 

protection devices. Observe the accident prevention regulations in force. Always refer to current local and/or 

national regulations, legislation and bylaws governing occupational health and safety in closed areas. 

Never work alone. When working inside the tank, make sure it contains no toxic and/or harmful gas. Observe 

local and/or national regulations, legislation and bylaws governing installations in explosive areas. 

Welding, cutting, melting, grinding or similar operations and the use of flames and heat sources and the like 

generate fire and/or explosion risks. For this type of operation, carefully remove potentially explosive powders 

and  gas  and/or  inflammable  material  present  in  the  work  and  surrounding  areas.  Make  sure  the  area  is 

sufficiently ventilated (explosion hazard). 

Staff working in sewers must be vaccinated against any illnesses that they may contract. Make sure there is a 

first-aid  kit  near  the  installation.  Make  sure  the  tank  lifting  system  works  correctly.  Make  sure  there  is  an 

emergency exit. Make sure suitable protection barriers are placed around the work area. 

Secure the cover before leaving the installation area.

4. 4. 4. 4. Applications Applications Applications Applications     Information for installers and user Information for installers and user Information for installers and user Information for installers and userssss    

After  installation  and  the  relative  hydraulic  and  electric  connections  of  the  pumps,  the  Maxibox  Plus  range  of  tanks  are  used  to 

collect and pump non-faecal wastewater (grey water) and faecal wastewater (black water) from collection points in buildings and 

sites lying underneath the level of the public / private sewer to which they are connected. 

4.1

4.1

4.1

4.1

Supply

Supply

Supply

Supply    

The tank is supplied complete with cover, taps and internal piping, grommets and inlet gasket. The electric pumps, electrical panel, 

level adjusters, chains and shackles and any other accessories must be ordered separately. 

4.2

4.2

4.2

4.2

Working limits

Working limits

Working limits

Working limits    

4.2.1

4.2.1

4.2.1

4.2.1

Pumped liquids, pressures, temperatures

Pumped liquids, pressures, temperatures

Pumped liquids, pressures, temperatures

Pumped liquids, pressures, temperatures    

Do not use the tank to pump hazardous, flammable and/or explosive liquids.

Do  not  use  the  tank  to  pump  water  containing  substances  and  materials  that  could  impair  the  correct 

performance  of  the  station,  the  electric  pumps  of  the  electrical  panel,  if  fitted,  and  other  station 

components (consult the relative instructions manual). 

Preferably  install  a  degreasing  bath  upline  from  the  tank  when  pumping  wastewater  containing  greasy 

material.

Maximum operating pressure depends on the model of pumps installed. Consult the pump documentation for further information. 

4.2.2

4.2.2

4.2.2

4.2.2

Storage limits

Storage limits

Storage limits

Storage limits    

Ambient temperature: Minimum -5 °C / Maximum + 40 °C 

WARNING 