Vitek VT-3549 SR: BATTERY INSTALLATION: REMOTE UNIT BATTERY INSTALLATION: MAIN UNIT LOW BATTERY WARNING HOW TO USE THE TABLE STAND OR WALL MOUNTING GETTING STARTED
BATTERY INSTALLATION: REMOTE UNIT BATTERY INSTALLATION: MAIN UNIT LOW BATTERY WARNING HOW TO USE THE TABLE STAND OR WALL MOUNTING GETTING STARTED: Vitek VT-3549 SR
Table of contents
- INTRODUCTION DESCRIPTION
- A DISPLAY
- MAIN FEATURES: REMOTE UNIT A LED INDICATOR BEFORE YOU BEGIN
- BATTERY INSTALLATION: REMOTE UNIT BATTERY INSTALLATION: MAIN UNIT LOW BATTERY WARNING HOW TO USE THE TABLE STAND OR WALL MOUNTING GETTING STARTED
- HOW TO CHECK REMOTE AND INDOOR TEMPERATURES HOW TO READ THE KINETIC WAVE DISPLAY MAXIMUM AND MINIMUM TEMPERATURES AND HUMIDITY
- TEMPERATURE AND HUMIDITY TREND WEATHER FORECAST ATMOSPHERIC PRESSURE COMFORT LEVEL INDICATORS
- HOW TO CHECK THE BAROMETRIC PRESSURE
- HOW TO USE AND SCAN THE MOON PHASE DISCONNECTED SIGNALS TRANSMISSION COLLISION
- HOW TO SET THE RADIO CONTROLLED CLOCK CALENDAR CLOCK DISPLAY MODES HOW TO SET THE CLOCK MANUALLY HOW TO SET AND ARM THE ALARM
- SNOOZE FEATURE HOW TO STOP AN ALARM ALARM FEATURE HOW TO CHANGE THE TEMPERATURE ALARM SETTING PRECAUTIONS
- SPECIFICATIONS

ENGLISH
Note that the effective range is vastly affected by the building materials and where the
main and remote units are positioned.
Try various set-ups for best result.
Though the remote units are weather proof, they should be placed away from direct
sunlight, rain or snow.
BATTERY INSTALLATION: REMOTE UNIT
1. Remove the screws on the battery compartment.
2. Select the channel
3. Install 2 batteries (UM-3 or “AA” size 1.5V) strictly according to the polarities
shown.
4. Replace the battery compartment door and secure its screws.
BATTERY INSTALLATION: MAIN UNIT
1. Open the battery compartment door.
2. Install 2 batteries (UM-3 or “AA” size 1.5V) strictly according to the polarities
shown.
3. Replace the battery compartment door.
LOW BATTERY WARNING
When it is time to replace batteries for the remote sensor, the respective low-battery in-
dicator [
] will show up on the indoor or outdoor temperature & hygrometer display.
HOW TO USE THE TABLE STAND OR WALL MOUNTING
The main unit has a removable table stand, which when connected, can support the
unit on a flat surface. Or you can remove the stand and mount the unit on a wall using
the recessed screw hole.
GETTING STARTED
1. SETTING UP THE BAROMETER
a. When batteries are installed, the display will shows the “hPa”, “mBar” and “mmHg”.
User should press the
“Unit” key to the unit of pressure, it will shows “0” and “meter”. User can use the “Up” or
“Down” keys to change to “feet”, or use the “Unit” key to confirm the unit.
b. After user confirmed the unit of height, it will shows “10” with “meter” or “32” with
“feet”. User can use the “Up” or “Down” keys to change to height of the place, and use
the “Unit” key to confirm the height.
Remark: The default unit of pressure is hPa/mBar, unit of height is meter, height is 10
meters. It will use the default value if no key is pressure for 60 seconds.
2. SETTING UP THE REMOTE TEMP. AND RC CLOCK
a. Once batteries are in place for the remote unit, they will start transmitting tempera-
ture and humidity readings at
5
3549.indd 549.indd 5 02.06.2006 16:59:3602.06.2006 16:59:36




