Milwaukee WCE 30: 16 17 ENGLISH ENGLISH

16 17 ENGLISH ENGLISH: Milwaukee WCE 30

TECHNICAL DATA Wall Chaser

WCE 30 (110 V) WCE 30

SPECIFIED CONDITIONS OF USE

SYMBOLS

Rated input .............................................................................

.......................1300 W .........................1500 W

The wall-chaser machine cuts slots for cables and pipes

No-load speed ........................................................................

.......................9500 /min ...................... 9500 /min

(masonry grooves) in any kind of brickwork with two

Please read the instructions carefully before

Grinding disk diameter............................................................

.........................125 mm ........................125 mm

diamond cutting discs running parallel to each other.

starting the machine.

Cutting depth ..........................................................................

........................8-30 mm .......................8-30 mm

Do not use this product in any other way as stated for

Cutting width ...........................................................................

......................19-26 mm .....................19-26 mm

normal use.

Weight according EPTA-Procedure 01/2003 ..........................

..........................4,3 kg ............................ 4,3 kg

EC-DECLARATION OF CONFORMITY

Always wear goggles when using the

Noise Information

machine.

We declare under our sole responsibility that this product is

Measured values determined according to EN 60 745.

in conformity with the following standards or standardized

Typically, the A-weighted noise levels of the tool are:

documents

Sound pressure level (K = 3 dB(A)) ......................................

...........................86 dB (A) ......................86 dB (A)

EN 60745

Sound power level (K = 3 dB(A)) ...........................................

...........................97 dB (A) ......................97 dB (A)

EN 55014-1:2006 + A1:2009 + A2:2011

Wear ear protectors!

EN 55014-2:1997 + A1:2001 + A2:2008

Always disconnect the plug from the socket

Vibration Information

EN 61000-3-2:2006 + A1:2009 + A2:2009

before carrying out any work on the

Total vibration values (vector sum in the three axes)

EN 61000-3-3:2008

machine.

determined according to EN 60745.

in accordance with the regulations

2

2

Vibration emission value a

: ...................................................

.............................7 m/s

............................7 m/s

h

2011/65/EU (RoHs)

2

2

Uncertainty K = ......................................................................

..........................1,5 m/s

.........................1,5 m/s

2006/42/EC

Accessory - Not included in standard

2004/108/EC

equipment, available as an accessory.

WARNING

The vibration emission level given in this information sheet has been measured in accordance with a standardised test given

in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.

Winnenden, 2012-10-26

Do not dispose of electric tools together

The declared vibration emission level represents the main applications of the tool. However if the tool is used for different

with household waste material! In

applications, with different accessories or poorly maintained, the vibration emission may differ. This may signicantly increase

observance of European Directive 2002/96/

the exposure level over the total working period.

EC on waste electrical and electronic

equipment and its implementation in

An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or

Rainer Kumpf

accordance with national law, electric tools

when it is running but not actually doing the job. This may signicantly reduce the exposure level over the total working period.

Director Product Development

that have reached the end of their life must

Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the

Authorized to compile the technical le

be collected separately and returned to an

accessories, keep the hands warm, organisation of work patterns.

environmentally compatible recycling

ADVICE FOR OPERATION

facility.

The machine switches off automatically if the motor is

overloaded. Allow it to cool, press the overload button and

Class II construction, tool in which

After switching off, the machine will not be idle immediately.

restart the machine. If the overload protection switches it off

WARNING! Read all safety warnings and all

protection against electric shock does not

(After-running of the work spindle.) Allow the machine to

frequently, reduce the cutting pressure or depth of cut.

instructions, including those given in the accompanying

rely on basic insulation only, but in which

come to a stop before putting down.

brochure. Failure to follow the warnings and instructions

The innitely variable cutting width setting has the

additional safety precautions, such as

may result in electric shock, re and/or serious injury.

Never reach into the danger area of the plane when it is

advantage that, if the groove width is set correctly, pipes etc.

double insulation or reinforced insulation,

Save all warnings and instructions for future reference.

running.

can be tted precisely into the groove and it is not

are provided.

necessary to secure them with nails etc. to prevent them

Always use the auxiliary handle.

SAFET INSTRUCTIONS

from falling out.

Only use tools whose permitted speed is at least as high as

Sharpen blunt diamond cutting blades (can be recognised

Wear ear protectors. Exposure to noise can cause hearing

the highest no-load speed of the machine.

by sparks ying while cutting) by making several cuts into

loss.

Immediately switch off the machine in case of considerable

calcareous sandstone or a special sharpening stone.

Use auxiliary handles supplied with the tool. Loss of

vibrations or if other malfunctions occur. Check the machine

The cutting discs get very hot when in use. Do not touch

control can cause personal injury.Appliances used at many

in order to nd out the cause.

them before they have cooled down.

different locations including open air must be connected via

Only use sharpened and awless diamond cutting discs.

a current surge preventing switch.

Immediately exchange bent or cracked diamond cutting

MAINTENANCE

Hold power tool by insulated gripping surfaces when

discs. Carry out a test run without load for at least 30

performing an operation where the cutting tool may

seconds.

The ventilation slots of the machine must be kept clear at all

contact hidden wiring or its own cord. Contact with a live

times.

Only use and store diamond cutting discs according to the

wire will also make exposed metal parts of the power tool

manufacturer‘s instructions.

Use only Milwaukee accessories and spare parts. Should

live and shock the operator.

components need to be exchanged which have not been

Pay attention to the dimensions of the cutting discs. The

Appliances used at many different locations including open

described, please contact one of our Milwaukee service

diameter of the centre hole must t the ange without play.

air should be connected via a residual current device of

agents (see our list of guarantee/service addresses).

Do not use any eduction pieces or adapters.

30 mA or less.

If needed, an exploded view of the tool can be ordered.

Only use the machine for dry cutting in stone.

Always wear goggles when using the machine. It is

Please state the Article No. as well as the machine type

Mind hidden electric lines, gas and water pipes. Check your

recommended to wear gloves, sturdy non slipping shoes

printed on the label and order the drawing at your local

working area, e.g. with a metal detector.

and apron.

service agents or directly at: Milwaukee Electric Tool,

The dust produced when using this tool may be harmful to

Max-Eyth-Straße 10, D-71364 Winnenden, Germany.

The dust that arises when working with this tool can be

health. Do not inhale the dust. Use a dust absorption system

detrimental to health and therefore not reach the body. Use

and wear a suitable dust protection mask. Remove

a dust absorption system and wear a suitable dust

deposited dust thoroughly, e.g. with a vacuum cleaner.

protection mask (protection level FFP2). Use ventilation in

enclosed spaces. Remove deposited dust thoroughly, e.g.

MAINS CONNECTION

with a vacuum cleaner.

Always disconnect the plug from the socket before carrying

Connect only to single-phase a.c. current and only to the

out any work on the machine.

system voltage indicated on the rating plate. It is also

possible to connect to sockets without an earthing contact

Only plug-in when machine is switched off.

as the design conforms to safety class II.

Keep mains lead clear from working range of the machine.

Always lead the cable away behind you.

16 17

ENGLISH ENGLISH