Hach-Lange High Output Airblast System (HOAB): инструкция
Раздел: Техника
Тип:
Инструкция к Hach-Lange High Output Airblast System (HOAB)

DOC023.98.80328
High Output Airblast System
10/2013, Edition 4
User Manual
Bedienungsanleitung
Manuale d'uso
Manuel d'utilisation
Manual del usuario
Manual do utilizador
Návod k použití
Gebruikershandleiding
Instrukcja obsługi
Bruksanvisning
Ръководство за потребителя
Felhasználói kézikönyv
Manual de utilizare
Руководство пользователя
Kullanıcı Kılavuzu
Navodila za uporabo
Korisnički priručnik

English..............................................................................................................................3
Deutsch..........................................................................................................................18
Italiano............................................................................................................................34
Français.........................................................................................................................50
Español..........................................................................................................................66
Português......................................................................................................................82
Čeština...........................................................................................................................98
Nederlands.................................................................................................................114
Polski............................................................................................................................130
Svenska.......................................................................................................................146
български...................................................................................................................160
Magyar.........................................................................................................................176
Română.......................................................................................................................192
Русский........................................................................................................................208
Türkçe...........................................................................................................................
224
Slovenski.....................................................................................................................240
Hrvatski........................................................................................................................256
2

Table of contents
Specifications on page 3 Maintenance on page 15
General information on page 3 Troubleshooting on page 16
Installation on page 6 Replacement parts on page 16
Startup on page 15
Specifications
Specifications are subject to change without notice.
Specification Details
Dimensions (W x D x H) 351.6 x 186.9 x 409.7 mm (13.84 x 7.36 x 16.13 in.)
Weight 11.2 kg (24.7 lb)
Output air pressure
115 V model: 3.10 bar (45 psi)
(at compressor outlet)
230 V model: 2.76 bar (40 psi)
3
Output air flow rate
115 V model: 2.14 m
/hour (1.26 cfm)
(at compressor outlet)
3
230 V model: 1.77 m
/hour (1.04 cfm)
Maximum pump duty cycle 60 seconds every 15 minutes
Operating requirements –20 to 50 °C (–4 to 122 °F), 95% relative humidity, non-condensing
Storage requirements –20 to 70 °C (–4 to 158 °F), 95% relative humidity, non-condensing
Enclosure NEMA 4X/IP66 non-metallic
Power requirements 115 V model: 115 VAC, 50/60 Hz, 7.5/4.5 A
230 V model: 230 VAC, 50 Hz, 2.5 A
Input fuse 115 V model: T, 8 A, 250 V
230 V model: T, 5 A, 250 V
Controller relay fuse T, 0.25 A, 250 V (all models)
Pollution degree 2
Installation category II
Protection class I
Altitude 2000 m (6560 ft) maximum
Compressor dimensions (W x D x H) 37 x 32 x 20 cm (14.5 x 12.5 x 7.8 in.)
Compressor weight 10.7 kg (23.5 lb)
Certifications UL, CSA, cETLus, CE
Warranty 1 year (EU: 2 years)
General information
In no event will the manufacturer be liable for direct, indirect, special, incidental or consequential
damages resulting from any defect or omission in this manual. The manufacturer reserves the right to
make changes in this manual and the products it describes at any time, without notice or obligation.
Revised editions are found on the manufacturer’s website.
English 3

Safety information
N O T I C E
The manufacturer is not responsible for any damages due to misapplication or misuse of this product including,
without limitation, direct, incidental and consequential damages, and disclaims such damages to the full extent
permitted under applicable law. The user is solely responsible to identify critical application risks and install
appropriate mechanisms to protect processes during a possible equipment malfunction.
Please read this entire manual before unpacking, setting up or operating this equipment. Pay
attention to all danger and caution statements. Failure to do so could result in serious injury to the
operator or damage to the equipment.
Make sure that the protection provided by this equipment is not impaired. Do not use or install this
equipment in any manner other than that specified in this manual.
Use of hazard information
D A N G E R
Indicates a potentially or imminently hazardous situation which, if not avoided, will result in death or serious injury.
W A R N I N G
Indicates a potentially or imminently hazardous situation which, if not avoided, could result in death or serious
injury.
C A U T I O N
Indicates a potentially hazardous situation that may result in minor or moderate injury.
N O T I C E
Indicates a situation which, if not avoided, may cause damage to the instrument. Information that requires special
emphasis.
Precautionary labels
Read all labels and tags attached to the instrument. Personal injury or damage to the instrument
could occur if not observed. A symbol on the instrument is referenced in the manual with a
precautionary statement.
This symbol, if noted on the instrument, references the instruction manual for operation and/or safety
information.
Electrical equipment marked with this symbol may not be disposed of in European public disposal
systems after 12 August of 2005. In conformity with European local and national regulations (EU
Directive 2002/96/EC), European electrical equipment users must now return old or end-of-life
equipment to the Producer for disposal at no charge to the user.
Note: For return for recycling, please contact the equipment producer or supplier for instructions on how to return end-
of-life equipment, producer-supplied electrical accessories, and all auxiliary items for proper disposal.
This symbol indicates that a risk of electrical shock and/or electrocution exists.
This symbol indicates the need for protective eye wear.
4 English

This symbol indicates that the marked item requires a protective earth connection. If the instrument is
not supplied with a ground plug on a cord, make the protective earth connection to the protective
conductor terminal.
This symbol, when noted on the product, identifies the location of a fuse or current limiting device.
Certification
Canadian Radio Interference-Causing Equipment Regulation, IECS-003, Class A:
Supporting test records reside with the manufacturer.
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing
Equipment Regulations.
Cet appareil numérique de classe A répond à toutes les exigences de la réglementation canadienne
sur les équipements provoquant des interférences.
FCC Part 15, Class "A" Limits
Supporting test records reside with the manufacturer. The device complies with Part 15 of the FCC
Rules. Operation is subject to the following conditions:
1. The equipment may not cause harmful interference.
2. The equipment must accept any interference received, including interference that may cause
undesired operation.
Changes or modifications to this equipment not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment. This equipment has been tested
and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules.
These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference, in which case the user will be required to
correct the interference at their expense. The following techniques can be used to reduce
interference problems:
1. Disconnect the equipment from its power source to verify that it is or is not the source of the
interference.
2. If the equipment is connected to the same outlet as the device experiencing interference, connect
the equipment to a different outlet.
3. Move the equipment away from the device receiving the interference.
4. Reposition the receiving antenna for the device receiving the interference.
5. Try combinations of the above.
Product overview
This cleaning system is used in process applications where the sensor can get dirty. This instrument
automatically cleans the sensor surface and removes slime and other bio-growth. Install this
instrument in an indoor or outdoor location that is not in direct sunlight.
Product components
Make sure that all components have been received. Refer to Figure 1. If any items are missing or
damaged, contact the manufacturer or a sales representative immediately.
English 5