Hach-Lange HQ11D Basic User Manual: инструкция

Раздел: Техника

Тип:

Инструкция к Hach-Lange HQ11D Basic User Manual

DOC022.98.80017

HQd Portable Meter

06/2013, Edition 4

Basic User Manual

Basis-Bedienungsanleitung

Manuale utente di base

Manuel d'utilisation de base

Manual básico del usuario

Manual de operações básicas

Základní uživatelská příručka

Grundlæggende brugervejledning

Basisgebruikershandleiding

Podstawowa instrukcja obsługi

Grundläggande bruksanvisning

Peruskäyttöohje

Основно ръководство за потребителя

Alap felhasználói kézikönyv

Manual de bază al utilizatorului

Bendroji naudotojo instrukcija

Основное руководство пользователя

Temel Kullanıcı Kılavuzu

Základný návod na použitie

Osnovni uporabniški priročnik

Osnovni korisnički priručnik

Βασικό εγχειρίδιο χρήστη

Kokkuvõtlik kasutusjuhend

Osnovno korisničko uputstvo

English...................................................................................................................................................................................................

3

Deutsch...............................................................................................................................................................................................17

Italiano.................................................................................................................................................................................................32

Français..............................................................................................................................................................................................46

Español...............................................................................................................................................................................................61

Português..........................................................................................................................................................................................76

Čeština................................................................................................................................................................................................91

Dansk.................................................................................................................................................................................................105

Nederlands......................................................................................................................................................................................119

Polski.................................................................................................................................................................................................134

Svenska............................................................................................................................................................................................149

Suomi.................................................................................................................................................................................................163

български.......................................................................................................................................................................................177

Magyar..............................................................................................................................................................................................193

Română............................................................................................................................................................................................207

lietuvių kalba...................................................................................................................................................................................222

Русский............................................................................................................................................................................................236

Türkçe................................................................................................................................................................................................252

Slovenský jazyk............................................................................................................................................................................266

Slovenski..........................................................................................................................................................................................281

Hrvatski.............................................................................................................................................................................................295

Ελληνικά...........................................................................................................................................................................................309

eesti keel..........................................................................................................................................................................................324

Српски..............................................................................................................................................................................................338

2

Table of contents

Specification Details

Specifications on page 3

Standard operation on page 10

Data memory (internal) 500 results

General information on page 3

Data management on page 11

Data storage Automatic in Press to Read mode and Interval

Installation on page 5

Maintenance on page 13

Mode. Manual in Continuous Read Mode.

User interface and navigation on page 7

Troubleshooting on page 14

Data export USB connection to PC or USB storage device

Startup on page 9

(limited to the storage device capacity). Transfer

entire data log or as readings are taken.

Connections Integrated USB type A (for USB flash memory

Specifications

device, printer, keyboard) and Integrated USB type

Specifications are subject to change without notice.

B (for PC)

Temperature correction Off, automatic and manual (parameter dependent)

Specification Details

Measurement display lock Continuous measurement, Interval or Press to Read

Dimensions 19.7 x 9.5 cm (7.75 x 3.75 in.)

mode. Averaging function for LDO probes.

Weight 335 g (0.75 lb) without batteries; 430 g (0.95 lb) with

Keyboard External PC keyboard connector via USB/DC

four AA alkaline batteries

adapter

Meter enclosure IP67, waterproof to 1 meter for 30 minutes

Battery enclosure Water resistant to 0.6 m (2 ft) for 15 seconds

General information

Power requirements

AA Alkaline or rechargeable Nickel Metal Hydride

Revised editions are found on the manufacturer’s website.

(internal)

(NiMH) batteries (4); battery life: up to 200 hours

Power requirements

Class II, external power adapter: 100–240 VAC,

Safety information

(external)

50/60 Hz input; 4.5 to 7.5 VDC (7 VA) output

N O T I C E

Meter protection class Class I

The manufacturer is not responsible for any damages due to misapplication or

misuse of this product including, without limitation, direct, incidental and

Storage temperature –20 to +60 °C (–4 to +140 °F)

consequential damages, and disclaims such damages to the full extent permitted

Operating temperature 0 to +60 °C (32 to 140 °F)

under applicable law. The user is solely responsible to identify critical application

risks and install appropriate mechanisms to protect processes during a possible

Operating humidity 90% (non-condensing)

equipment malfunction.

5-pin input connector M12 connector for IntelliCAL

probes

Please read this entire manual before unpacking, setting up or operating

this equipment. Pay attention to all danger and caution statements.

8-pin input connector The 8-pin connector enables USB and external AC

Failure to do so could result in serious injury to the operator or damage

power connectivity

to the equipment.

USB/DC adapter Peripheral and host

English 3

Make sure that the protection provided by this equipment is not impaired.

This symbol, if noted on the instrument, references the instruction

Do not use or install this equipment in any manner other than that

manual for operation and/or safety information.

specified in this manual.

Use of hazard information

This symbol indicates that the marked item can be hot and should not

be touched without care.

D A N G E R

Indicates a potentially or imminently hazardous situation which, if not avoided, will

result in death or serious injury.

Electrical equipment marked with this symbol may not be disposed of

in European public disposal systems after 12 August of 2005. In

W A R N I N G

conformity with European local and national regulations (EU Directive

2002/96/EC), European electrical equipment users must now return

Indicates a potentially or imminently hazardous situation which, if not avoided,

old or end-of-life equipment to the Producer for disposal at no charge

could result in death or serious injury.

to the user.

Note: For return for recycling, please contact the equipment producer or supplier

C A U T I O N

for instructions on how to return end-of-life equipment, producer-supplied

electrical accessories, and all auxiliary items for proper disposal.

Indicates a potentially hazardous situation that may result in minor or moderate

injury.

Product overview

N O T I C E

The HQd series portable meters are used with digital IntelliCAL

probes

Indicates a situation which, if not avoided, may cause damage to the instrument.

to measure various parameters in water. The meter automatically

Information that requires special emphasis.

recognizes the type of probe that is connected to the meter.

Measurement data can be stored and transferred to a printer, PC or USB

Precautionary labels

storage device.

Read all labels and tags attached to the instrument. Personal injury or

The HQd series meters are available in 4 models:

damage to the instrument could occur if not observed. A symbol on the

HQ11d—pH/mV/ORP

instrument is referenced in the manual with a precautionary statement.

HQ14d—conductivity, salinity, total dissolved solids (TDS), resistivity

HQ30d—all IntelliCAL probes, 1 probe connector

HQ40d—all IntelliCAL probes, 2 probe connectors

Features common to all models:

Automatic probe and parameter recognition

Instrument guided calibration procedures

Calibration data stored in the probe

Probe specific method settings for regulatory compliance and Good

Laboratory Practice (GLP)

Security Options

4 English

Real-time data logging via USB connection

Figure 2 Meter components (HQ11d, HQ14d and HQ30d models)

USB connectivity to PC/printer/USB storage device/keyboard

Bi-directional communication with PC-based systems via a virtual

serial port connection

Sample ID and Operator ID for data traceability

Adjustable automatic shut-off

Product components

Refer to Figure 1 and Figure 2 to make sure that all components have

been received. If any items are missing or damaged, contact the

manufacturer or a sales representative immediately.

Figure 1 Meter components (HQ40d model)

1 Meter 2 AA batteries (pk/4)

Installation

C A U T I O N

Multiple hazards. Only qualified personnel must conduct the tasks

described in this section of the document.

1 Meter 4 AC-DC power supply

2 AA batteries (pk/4) 5 USB/DC adapter

3 AC power cord

English 5

Install the batteries

Figure 3 Battery installation

W A R N I N G

Explosion hazard. Incorrect battery installation can cause the release of explosive

gases. Be sure that the batteries are of the same approved chemical type and

are inserted in the correct orientation. Do not mix new and used batteries.

N O T I C E

The battery compartment is not waterproof. If the battery compartment becomes

wet, remove and dry the batteries and dry the interior of the compartment. Check

the battery contacts for corrosion and clean them if necessary.

N O T I C E

When using nickel metal hydride (NiMH) batteries, the battery icon will not

indicate a full charge after freshly charged batteries have been inserted (NiMH

batteries are 1.2 V versus 1.5 V for alkaline batteries). Even though the icon does

not indicate complete charge, 2300 mAH NiMH batteries will achieve 90% of

instrument operation lifetime (before recharge) versus new alkaline batteries.

N O T I C E

To avoid potential damage to the meter from battery leakage, remove the meter

batteries prior to extended periods of non-use.

The meter can be powered with AA alkaline or rechargeable NiMH

batteries. To conserve battery life, the meter will power off after

5 minutes of inactivity. This time can be changed in the Display Options

menu.

For battery installation refer to Figure 3.

1 Batteries 2 Release tab 3 Battery cover

1. Pull the release tab on the battery cover and the remove the cover.

2. Install 4 AA alkaline or 4 AA nickel metal hydride (NiMH) batteries.

Connect to AC power

Make sure that the batteries are installed in the correct polarity.

3. Replace the battery cover.

D A N G E R

Electrocution Hazard. AC power outlets in wet or potentially wet

locations MUST ALWAYS be provided with a Ground Fault Circuit

Interrupting (GFCI/GFI) circuit breaker. The AC-DC power adapter for

this product is not sealed and must not be used on wet benches or in

wet locations without GFCI protection.

6 English

Аннотация для Hach-Lange HQ11D Basic User Manual в формате PDF