Vitek VT-1763: REMOTE CONTROL (17) Correspondence of the remote control buttons to the buttons on the control panel of the unit: Cleaning the filter CLEANING AND CARE Replacement of the filter-cartridge (13) Storage Weekly care
REMOTE CONTROL (17) Correspondence of the remote control buttons to the buttons on the control panel of the unit: Cleaning the filter CLEANING AND CARE Replacement of the filter-cartridge (13) Storage Weekly care: Vitek VT-1763
Table of contents
- DESCRIPTION Display indications (7) (pic. 1) Remote control (19) (pic. 2) SAFETY MEASURES
- FOR HOUSEHOLD USAGE ONLY USING THE HUMIDIFIER
- REMOTE CONTROL (17) Correspondence of the remote control buttons to the buttons on the control panel of the unit: Cleaning the filter CLEANING AND CARE Replacement of the filter-cartridge (13) Storage Weekly care
- TROUBLESHOOTING GUIDE Problem Possible cause Solution SPECIFICATIONS GUARANTEE

ENGLISH
REMOTE CONTROL (17)
lution. After that, carefully rinse them with
For convenient control of the unit, use the
water.
remote control.
• Add 5-10 drops of the cleaning agent on
If there is an isolation insert in the battery
the “nebulizer” (15); wait about 2-5 min-
compartment, remove it, if the battery is
utes. Use the brush (18) to remove the
supplied separately, remove the holder of the
deposit from the surface of the “nebulizer”
battery, by preliminary pressing the clamp,
(15).
insert the battery in the holder, strictly fol-
lowing the polarity, insert the battery holder
Note: As a cleaning agent for the “neb-
into the remote control. The distance from
ulizer” you can use substances for
the remote control to the humidifier shall not
scale removal in kettles.
exceed 5 meters and the angle of 30°.
• Do not immerse the unit into water or other
Correspondence of the remote control
liquids.
buttons to the buttons on the control
panel of the unit:
Cleaning the filter
29. Power on/off button - (6).
• Clean the filter (13) when there are first
30. Timer setting button – (5).
signs of a “film” on the furniture items.
31. Steam-out intensity button - (1).
• Take the handle (10) and remove the water
32, 33 Indoor humidity setting buttons - (2),
tank (10) from the body of the unit (16).
(3).
• Turn over the water tank (11), unscrew the
34. Ionization mode on/off button - (4).
lid (14) by turning it counterclockwise and
remove the filter-cartridge (13), by turning
CLEANING AND CARE
it counterclockwise.
Warning: Always switch off and unplug
• Wash the filter-cartridge (13) with running
the unit before cleaning it.
water and put it for 50-60 minutes into the
bowl with salt solution (2-3 table spoons
Hard water causes the appearance of scale
for 0,5 liter of water), put off the cartridge
on the “nebulizer”, on the inner parts of the
and wash it with running water.
body and on the water tank; it leads to im-
• Place the filter-cartridge (13) back on the
proper operation of the unit and appearance
lid (14), by turning it clockwise.
of white deposit on the interior. In order to
avoid it, it is necessary to clean the nebulizer
Replacement of the filter-cartridge (13)
every day and replace water as often as pos-
Replace the filter-cartridge (13) when nec-
sible, as well as to perform cleaning of the
essary.
filter-cartridge (13).
If you are not going to use the unit for a long
Storage
time: - pour out water from the tank and the
- If you are not going to use the unit for a
operating chamber of the “nebulizer”, wash
long time, make sure that all its parts are
the water tank, wash and clean the operating
dry, including the operating chamber of
chamber of the “nebulizer” and the “neb-
the “nebulizer”.
ulizer” itself, dry the unit and put it away for
- Do not store the device with water in the
storage.
operating chamber.
- Before you put the filter-cartridge away for
Weekly care
storage, clean and dry it, keep the filter-
• Once a week carefully wash the water tank
cartridge in a cool dark place.
(11) and the operating chamber under the
Store the humidifier in a dry cool place out
tank(11) with a neutral washing liquid so-
of reach of children.