Milwaukee M1418C6: 6 7 ENGLISH ENGLISH

6 7 ENGLISH ENGLISH: Milwaukee M1418C6

TECHNICAL DATA Charger

M1418C6 (220V-240V) M1418C6 (110V)

The charger can charge 6 batteries at the same time. The

EC-DECLARATION OF CONFORMITY

batteries are loaded into the sequence in which they were

Voltage range .........................................................................

...........14,4 V, 18 V ..............................14,4 V, 18 V

We declare under our sole responsibility that the product

inserted.

Quick charge current ..............................................................

......................3,5 A .........................................3,5 A

described under “Technical Data” fullls all the relevant

Red continuous light: charging

Maintaining charge current .....................................................

.....................750 mA .....................................750 mA

regulations and the directives 2011/65/EU (RoHs),

Red ashing slowly: battery pack on hold

Battery charging time with 1.5 Ah ...........................................

.......................30 min ......................................30 min

2006/95/EC, 2004/108/EC and the following harmonized

Green continuous light: battery pack charged.

Battery charging time with 3.0 Ah ...........................................

.......................60 min ......................................60 min

standards have been used:

Weight according EPTA-Procedure 01/2003 ..........................

....................1,92 kg .....................................1,92 kg

EN55014-1:2006 + A1:2009 + A2:2011

EN55014-2:1997 + A1:2001 + A2:2008

EN61000-3-2:2006 + A1:2009 + A2:2009

WARNING! Read all safety warnings and all

Li-Ion BATTERIES

EN61000-3-3:2008

instructions, including those given in the accompanying

EN60335-1:2002 + A1:2004 + A11:2004 + A12:2006 +

The rechargeable batteries are partially charged. The LED

brochure. Failure to follow the warnings and instructions

A2:2006 + A13:2008 + A14:2010 + A15:2011

on the battery indicates the state of charge.

may result in electric shock, re and/or serious injury.

EN60335-2-29:2004 + A2:2010

Save all warnings and instructions for future reference.

If it is not used for long periods, the rechargeable battery will

EN62233:2008

switch to the non-operative state.

SAFETY INSTRUCTIONS

When fully discharged the rechargeable battery switches off

Winnenden, 2012-10-10

Do not dispose of used battery packs in the household

automatically (depth discharge not possible).

refuse or by burning them. Milwaukee Distributors offer to

Under extreme circumstances, the internal temperatur of the

retrieve old batteries to protect our environment.

battery could become to high. If this happens, the battery

Only the following battery packs can be charged with this

will shut down.

Rainer Kumpf

charger:

Place the battery on the charger to charge and reset it.

Director Product Developement

voltage battery rating No. of

The state of charge can be read by pressing the button on

Authorized to compile the technical le.

(of storage battery) battery

the rechargeable battery. The battery can be left in the

cells

Techtronic Industries GmbH

electric tool while the reading is taken but it must be

Max-Eyth-Straße 10

14.4 V C14 B ≤ 1.5 Ah 4

switched off at least one minute beforehand (otherwise the

D-71364 Winnenden

14.4 V C14 BX ≤ 3.0 Ah 2 x 4

display will be inaccurate). The number of LEDs illuminated

14.4 V M14 B ≤ 1.5 Ah 4

indicates the state of charge. A ashing LED indicates a

SYMBOLS

14.4 V M14 BX ≤ 3.0 Ah 2 x 4

max. power reserve of 10%.

To skip a pack and move to the next pack, press the skip

button

18 V C18 B ≤ 1.5 Ah 5

As a general principle, if the electric tool should fail to work

18 V C18 BX ≤ 3.0 Ah 2 x 5

after inserting the rechargeable battery, then the battery

Please read the instructions carefully before

18 V M18 B ≤ 1.5 Ah 5

should be plugged into the charger. The displays on the

starting.

18 V M18 BX ≤ 3.0 Ah 2 x 5

battery and charger will then provide information about the

condition of the battery.

18 V M18 B2 ≤ 2.0 Ah 5

18 V M18 B4 ≤ 4.0 Ah 2 x 5

In low temperatures work may continue at reduced output.

CHARACTERISTICS

Do not try to charge non-rechargeable batteries with this

Do not burn used battery packs.

charger.

After inserting the battery into the reception of the charger

the battery will automatically be charged (red control lamp is

Do not store the battery pack together with metal objects

illuminated continuously)

(short circuit risk).

When a hot or cold battery pack is inserted into the charger

No metal parts must be allowed to enter the battery section

(ashing red lamp), charging will begin automatically once

of the charger (short circuit risk).

Do not dispose of electric tools together with

the battery reaches the correct charging temperature

household waste material! In observance of

Never break open battery packs or chargers and store only

(0°C...6C). The max. charging current is owing when the

European Directive 2002/96/EC on waste electrical

in dry rooms. Keep dry at all times.

temperature of the Li-Ion-battery is between 0°C and 60°C.

and electronic equipment and its implementation in

The battery clamps of the charger are fed by the mains

The battery’s charging time is between 1 min and 30 min (at

accordance with national law, electric tools that

supply. Do not touch the tool with conducting objects.

1,5 Ah), depending on the state of discharge.

have reached the end of their life must be collected

separately and returned to an environmentally

Never charge a damaged battery pack. Replace by a new

Once the battery is fully charged, the LED on the charger

compatible recycling facility.

one.

changes from red to green.

Before use check machine, cable, and plug for any

It is not necessary to remove the battery after charging. The

damages or material fatigue. Repairs should only be carried

battery can be stored permanently in the charger without the

Never charge a damaged battery pack.

out by authorised Service Agents.

MAINTENANCE

danger of being overcharged.

Replace with a new one.

This appliance is not intended for use by persons (including

If both LEDs ash alternately then the rechargeable battery

If the supply cord of this appliance is damaged, it must only

children) with limited physical, sensory or mental capabilities

is either not fully pushed in or there is a fault with the battery

be replaced by a repair shop appointed by the manufacturer,

or insufcient experience and/or knowledge unless they are

or charger. Take the charger and battery out of use

because special purpose tools are required

supervised by a person who is responsible for their safety or

This tool is only suitable for indoor use. Never

immediately for safety reasons and have them inspected by

Use only Milwaukee accessories and Milwaukee spare parts.

have been instructed by them in the safe use of the tool.

expose tool to rain.

a Milwaukee customer service centre.

Should components need to be replaced which have not

Children should be supervised in order to ensure that they

been described, please contact one of our Milwaukee service

do not play with the tool.

agents (see our list of guarantee/service addresses).

SPECIFIED CONDITIONS OF USE

If needed, an exploded view of the tool can be ordered.

Please state the Article No. as well as the machine type

This charger charges 14.4V and18V Milwaukee Li-Ion

printed on the label and order the drawing at your local

battery packs.

service agents or directly at: Techtronic Industries GmbH,

Do not use this product in any other way as stated for

Max-Eyth-Straße 10, D-71364 Winnenden, Germany.

normal use.

MAINS CONNECTION

Connect only to single-phase AC current and only to the

system voltage indicated on the rating plate. It is also

possible to connect to sockets without an earthing contact

as the design conforms to safety class II.

6 7

ENGLISH ENGLISH