Milwaukee C12 PXP: 16 17 ENGLISH ENGLISH

16 17 ENGLISH ENGLISH: Milwaukee C12 PXP

TECHNICAL DATA Battery Expander

C 12 PXP

BATTERIES

MAINTENANCE

Stroke ...........................................................................................

.......................................... 14 mm

New battery packs reach full loading capacity after 4 - 5

The ventilation slots of the machine must be kept clear at all

Pipe diameter ...............................................................................

...... ≤ ø 32 x 2,9, ≤ ø 25 x 3,5 mm

chargings and dischargings. Battery packs which have not

times.

Battery voltage..............................................................................

.......................................... 12 V

been used for some time should be recharged before use.

Use the supplied grease tube to lubricant the Q&E expander

Weight according EPTA-Procedure 01/2003 ................................

....................................... 1,88 kg

Temperatures in excess of 50°C (122°F) reduce the

heads.

performance of the battery pack. Avoid extended exposure

Daily or at least every 100 connections, clean the cone of

Noise/vibration information

to heat or sunshine (risk of overheating).

the tool and lubricate the cone. Use a clean, lint-free cloth to

Measured values determined according to EN 60 745.

The contacts of chargers and battery packs must be kept

apply a thin coat of lubricant (Molycote G-n plus) to the

Typically, the A-weighted noise levels of the tool are:

clean.

expander cone. Keep all other parts of the tool free from

Sound pressure level (K = 3 dB(A)) ............................................

.......................................... 61 dB (A)

lubricant.

For an optimum life-time, after use, the battery packs have

Sound power level (K = 3 dB(A)) .................................................

.......................................... 72 dB (A)

to be fully charged.

When using Uponor Standard expander heads extra grease

Wear ear protectors!

needs to be applied in interface between the tool and the

To obtain the longest possible battery life remove the battery

Total vibration values (vector sum in the three axes) determined

expander head.

pack from the charger once it is fully charged.

according to EN 60745.

Regularly clean the inside of the expander heads using a

2

For battery pack storage longer than 30 days:

Vibration emission value a

h

.......................................................

...................................... < 2,5 m/s

dry cloth. Avoid any build-up grease in between the

2

Store the battery pack where the temperature is below 27°C

Uncertainty K= ...........................................................................

......................................... 1,5 m/s

segments. It is essential to keep the outside of the

and away from moisture

segments free from grease and dry.

Store the battery packs in a 30% - 50% charged condition

Every six months of storage, charge the pack as normal.

Improper lubrication (too much, or too little) may result in

faulty connections, which could result in property damage.

WARNING

ADVICE FOR OPERATION

Use only Uponor approved expander heads.

The vibration emission level given in this information sheet has been measured in accordance with a standardised test given

Quick and Easy (Q&E) is a tting concept for Uponor-PEX

in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.

Use only Milwaukee accessories and Milwaukee spare

pipes and systems. The joint is made gradually expanding

parts. Should components need to be replaced which have

The declared vibration emission level represents the main applications of the tool. However if the tool is used for different

the pipe with a Q&E Ring tted to its outside, and then

not been described, please contact one of our Milwaukee

applications, with different accessories or poorly maintained, the vibration emission may differ. This may signicantly increase

allowing it to shrink over the tting nipple. Only genuine

service agents (see our list of guarantee/service addresses).

the exposure level over the total working period.

Q&E ttings, rings and expander tools may be used.

If needed, an exploded view of the tool can be ordered.

An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or

After expanding push immediately the expanded pipe and

Please state the Article No. as well as the machine type

when it is running but not actually doing the job. This may signicantly reduce the exposure level over the total working period.

ring over the nipple. If the pipe already be shrunk back, do

printed on the label and order the drawing at your local

Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the

not expand again, but cut the expanded part.

service agents or directly at: Milwaukee Electric Tool,

accessories, keep the hands warm, organisation of work patterns.

The expansion is done in several stages. This is clearly

Max-Eyth-Straße 10, D-71364 Winnenden, Germany.

audible the "click" upon contraction of the expander head.

The number of expansions is depend by the pipe diameter.

SYMBOLS

Typically:

WARNING! Read all safety warnings and all

SPECIFIED CONDITIONS OF USE

16 x 1.8 mm - 4 expandings

instructions, including those given in the accompanying

Remove the battery pack before starting any

The cordless expander is intended to be used to expand

20 x 1.9 mm - 6 expandings

brochure. Failure to follow the warnings and instructions

work on the machine.

plastic pipes for installation of Q&E ttings.

25 x 2.3 mm - 8 expandings

may result in electric shock, re and/or serious injury.

16 x 2.2 mm - 6 expandings

Save all warnings and instructions for future reference.

Do not use this product in any other way as stated for

20 x 2.8 mm - 12 expandings

normal use.

25 x 3.5 mm - 20 expandings

SAFETY INSTRUCTIONS

Do not dispose of electric tools together with

Do not expand more times than necessary.

EC-DECLARATION OF CONFORMITY

household waste material! In observance of

Do not change the properties or shape of the tool. It is

Each time the segments contract the expander head has to

European Directive 2002/96/EC on waste

particulary important not to change the shape or size of the

We declare under our sole responsibility that this product is

rotate 1/8 turn.

electrical and electronic equipment and its

cone by machining it or by altering its original properties,

in conformity with the following standards or standardized

documents. EN 60745, EN 55014-1, EN 55014-2, in

This rotation prevents a too deep incision of the expander

implementation in accordance with national

hardness, strenght, etc. by heating the tool or keeping it in

accordance with the regulations 2006/42/EC, 2004/108/EC

into the inner side of the pipe.

law, electric tools that have reached the end of

the vicinity of high temperature heat sources

If the expander not rotating the piping may cause deep

their life must be collected separately and

Use the tool correctly. Take particular care to tighten the

grooves and faulty connections, which could result in

returned to an environmentally compatible

expander head onto the tool in order to achieve full

leaking and property damage.

recycling facility.

expansion. Make sure the segments of the expander head

Milwaukee expander heads will rotate automatically at each

are not bend or damaged otherwise.

Winnenden, 2012-05-27

expansion. This is checked from time to time without pipe.

Never use, carry or put away the tool without a expander

Uponor Standard expander heads will not rotate

head on it.

automatically. It is necessary to rotate the pipe 1/8 turn by

Keep ngers and hands away from the expander head

hand.

moving area.

Rainer Kumpf

Do not dispose of used battery packs in the household

Director Product Development

COLD WEATHER INSTALLATION

refuse or by burning them. Milwaukee Distributors offer to

Authorized to compile the technical le

At low temperatures it takes longer for the pipe to shrink

retrieve old batteries to protect our environment.

onto the nippel and seal proberly.

Do not store the battery pack together with metal objects

Depending on pipe size, fewer expansions are necessary in

(short circuit risk).

cold temperatures.

No metal parts must be allowed to enter the battery section

The tool with battery must be warmed up before operating in

of the charger (short circuit risk).

temperatures below 5°C by doing some cycles without pipe.

Use only C 12 chargers for charging C 12 battery packs. Do

not use battery packs from other systems.

TIGHTNESS TESTING

Never break open battery packs and chargers and store

The tting joint can be pressurized after 30 minutes at

only in dry rooms. Keep dry at all times.

temperatures down to +5°C.

Battery acid may leak from damaged batteries under

At lower temperature increases the waiting time as follows:

extreme load or extreme temperatures. In case of contact

+ 5°C... 0°C: 1,5 h

with battery acid wash it off immediately with soap and

0°C...- 5°C: 3 h

water. In case of eye contact rinse thoroughly for at least 10

- 5°C...-10°C: 4 h

minutes and immediately seek medical attention.

-10°C...-15°C: 10 h

At room temperature, the joint will be as strong as the pipe

itself after, within 6 and 24 hours.

Tightness testing in accordance with the relevant standards

(ANV 12108) shall be carried out before the system is taken

into operation.

16 17

ENGLISH

ENGLISH