TECHNICAL DATA Battery Expander
C 12 PXP
BATTERIES
MAINTENANCE
Stroke ...........................................................................................
.......................................... 14 mm
New battery packs reach full loading capacity after 4 - 5
The ventilation slots of the machine must be kept clear at all
Pipe diameter ...............................................................................
...... ≤ ø 32 x 2,9, ≤ ø 25 x 3,5 mm
chargings and dischargings. Battery packs which have not
times.
Battery voltage..............................................................................
.......................................... 12 V
been used for some time should be recharged before use.
Use the supplied grease tube to lubricant the Q&E expander
Weight according EPTA-Procedure 01/2003 ................................
....................................... 1,88 kg
Temperatures in excess of 50°C (122°F) reduce the
heads.
performance of the battery pack. Avoid extended exposure
Daily or at least every 100 connections, clean the cone of
Noise/vibration information
to heat or sunshine (risk of overheating).
the tool and lubricate the cone. Use a clean, lint-free cloth to
Measured values determined according to EN 60 745.
The contacts of chargers and battery packs must be kept
apply a thin coat of lubricant (Molycote G-n plus) to the
Typically, the A-weighted noise levels of the tool are:
clean.
expander cone. Keep all other parts of the tool free from
Sound pressure level (K = 3 dB(A)) ............................................
.......................................... 61 dB (A)
lubricant.
For an optimum life-time, after use, the battery packs have
Sound power level (K = 3 dB(A)) .................................................
.......................................... 72 dB (A)
to be fully charged.
When using Uponor Standard expander heads extra grease
Wear ear protectors!
needs to be applied in interface between the tool and the
To obtain the longest possible battery life remove the battery
Total vibration values (vector sum in the three axes) determined
expander head.
pack from the charger once it is fully charged.
according to EN 60745.
Regularly clean the inside of the expander heads using a
2
For battery pack storage longer than 30 days:
Vibration emission value a
h
.......................................................
...................................... < 2,5 m/s
dry cloth. Avoid any build-up grease in between the
2
Store the battery pack where the temperature is below 27°C
Uncertainty K= ...........................................................................
......................................... 1,5 m/s
segments. It is essential to keep the outside of the
and away from moisture
segments free from grease and dry.
Store the battery packs in a 30% - 50% charged condition
Every six months of storage, charge the pack as normal.
Improper lubrication (too much, or too little) may result in
faulty connections, which could result in property damage.
WARNING
ADVICE FOR OPERATION
Use only Uponor approved expander heads.
The vibration emission level given in this information sheet has been measured in accordance with a standardised test given
Quick and Easy (Q&E) is a tting concept for Uponor-PEX
in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.
Use only Milwaukee accessories and Milwaukee spare
pipes and systems. The joint is made gradually expanding
parts. Should components need to be replaced which have
The declared vibration emission level represents the main applications of the tool. However if the tool is used for different
the pipe with a Q&E Ring tted to its outside, and then
not been described, please contact one of our Milwaukee
applications, with different accessories or poorly maintained, the vibration emission may differ. This may signicantly increase
allowing it to shrink over the tting nipple. Only genuine
service agents (see our list of guarantee/service addresses).
the exposure level over the total working period.
Q&E ttings, rings and expander tools may be used.
If needed, an exploded view of the tool can be ordered.
An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or
After expanding push immediately the expanded pipe and
Please state the Article No. as well as the machine type
when it is running but not actually doing the job. This may signicantly reduce the exposure level over the total working period.
ring over the nipple. If the pipe already be shrunk back, do
printed on the label and order the drawing at your local
Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the
not expand again, but cut the expanded part.
service agents or directly at: Milwaukee Electric Tool,
accessories, keep the hands warm, organisation of work patterns.
The expansion is done in several stages. This is clearly
Max-Eyth-Straße 10, D-71364 Winnenden, Germany.
audible the "click" upon contraction of the expander head.
The number of expansions is depend by the pipe diameter.
SYMBOLS
Typically:
WARNING! Read all safety warnings and all
SPECIFIED CONDITIONS OF USE
16 x 1.8 mm - 4 expandings
instructions, including those given in the accompanying
Remove the battery pack before starting any
The cordless expander is intended to be used to expand
20 x 1.9 mm - 6 expandings
brochure. Failure to follow the warnings and instructions
work on the machine.
plastic pipes for installation of Q&E ttings.
25 x 2.3 mm - 8 expandings
may result in electric shock, re and/or serious injury.
16 x 2.2 mm - 6 expandings
Save all warnings and instructions for future reference.
Do not use this product in any other way as stated for
20 x 2.8 mm - 12 expandings
normal use.
25 x 3.5 mm - 20 expandings
SAFETY INSTRUCTIONS
Do not dispose of electric tools together with
Do not expand more times than necessary.
EC-DECLARATION OF CONFORMITY
household waste material! In observance of
Do not change the properties or shape of the tool. It is
Each time the segments contract the expander head has to
European Directive 2002/96/EC on waste
particulary important not to change the shape or size of the
We declare under our sole responsibility that this product is
rotate 1/8 turn.
electrical and electronic equipment and its
cone by machining it or by altering its original properties,
in conformity with the following standards or standardized
documents. EN 60745, EN 55014-1, EN 55014-2, in
This rotation prevents a too deep incision of the expander
implementation in accordance with national
hardness, strenght, etc. by heating the tool or keeping it in
accordance with the regulations 2006/42/EC, 2004/108/EC
into the inner side of the pipe.
law, electric tools that have reached the end of
the vicinity of high temperature heat sources
If the expander not rotating the piping may cause deep
their life must be collected separately and
Use the tool correctly. Take particular care to tighten the
grooves and faulty connections, which could result in
returned to an environmentally compatible
expander head onto the tool in order to achieve full
leaking and property damage.
recycling facility.
expansion. Make sure the segments of the expander head
Milwaukee expander heads will rotate automatically at each
are not bend or damaged otherwise.
Winnenden, 2012-05-27
expansion. This is checked from time to time without pipe.
Never use, carry or put away the tool without a expander
Uponor Standard expander heads will not rotate
head on it.
automatically. It is necessary to rotate the pipe 1/8 turn by
Keep ngers and hands away from the expander head
hand.
moving area.
Rainer Kumpf
Do not dispose of used battery packs in the household
Director Product Development
COLD WEATHER INSTALLATION
refuse or by burning them. Milwaukee Distributors offer to
Authorized to compile the technical le
At low temperatures it takes longer for the pipe to shrink
retrieve old batteries to protect our environment.
onto the nippel and seal proberly.
Do not store the battery pack together with metal objects
Depending on pipe size, fewer expansions are necessary in
(short circuit risk).
cold temperatures.
No metal parts must be allowed to enter the battery section
The tool with battery must be warmed up before operating in
of the charger (short circuit risk).
temperatures below 5°C by doing some cycles without pipe.
Use only C 12 chargers for charging C 12 battery packs. Do
not use battery packs from other systems.
TIGHTNESS TESTING
Never break open battery packs and chargers and store
The tting joint can be pressurized after 30 minutes at
only in dry rooms. Keep dry at all times.
temperatures down to +5°C.
Battery acid may leak from damaged batteries under
At lower temperature increases the waiting time as follows:
extreme load or extreme temperatures. In case of contact
+ 5°C... 0°C: 1,5 h
with battery acid wash it off immediately with soap and
0°C...- 5°C: 3 h
water. In case of eye contact rinse thoroughly for at least 10
- 5°C...-10°C: 4 h
minutes and immediately seek medical attention.
-10°C...-15°C: 10 h
At room temperature, the joint will be as strong as the pipe
itself after, within 6 and 24 hours.
Tightness testing in accordance with the relevant standards
(ANV 12108) shall be carried out before the system is taken
into operation.
16 17
ENGLISH
ENGLISH
Оглавление
- 2 3
- START STOP
- 6 7
- 8 9
- 10 11
- 12 13
- 14 15
- 16 17 ENGLISH ENGLISH
- 18 19 DEUTSCH DEUTSCH
- 20 21 FRANÇAIS FRANÇAIS
- 22 23 ITALIANO ITALIANO
- 24 25 ESPAÑOL ESPAÑOL
- 26 27 PORTUGUES PORTUGUES
- 28 29 NEDERLANDS NEDERLANDS
- 30 31 DANSK DANSK
- 32 33 NORSK NORSK
- 34 35 SVENSKA SVENSKA
- 36 37 SUOMI SUOMI
- 38 39 ÅËËÇNÉÊÁ ÅËËÇNÉÊÁ
- 40 41 TÜRKÇE TÜRKÇE
- 42 43 ČESKY ČESKY
- 44 45
- 46 47 POLSKI POLSKI
- 48 49 MAGYAR MAGYAR
- 50 51 SLOVENSKO SLOVENSKO
- 52 53 HRVATSKI HRVATSKI
- 54 55 LATVISKI LATVISKI
- 56 57
- 58 59 EESTI EESTI
- 60 61 ÐÓÑÑÊÈÉ ÐÓÑÑÊÈÉ
- 62 63 БЪЛГАÐÑÊÈ БЪЛГАÐÑÊÈ
- 64 65 ROMÂNIA ROMÂNIA
- 66 67 МАКЕДОНСКИ МАКЕДОНСКИ
- 68 69 中文 中文
- 70 71