Delonghi KD-LA60: ENGLISH
ENGLISH: Delonghi KD-LA60
this product, please contact your local authority, domestic
GB
ENGLISH
waste collection service or the shop where the appliance was
purchased.
GENERAL
INSTALLATION INSTRUCTIONS
Carefully read the following important information regarding
installation safety and maintenance. Keep this information
booklet accessible for further consultations. The appliance
-
has been designed for use in the ducting version (air exhaust
lation.
to the outside - Fig.1B), filtering version (air circulation on the
inside - Fig.1A) or with external motor (Fig.1C).
- The appliance has been manufactured as a class II, therefore
SAFETY PRECAUTION
no earth cable is necessary. The plug must be easily acces-
sible after the installation of the appliance. If the appliance
is equipped with power cord without plug, a suitably di-
1. Take care when the cooker hood is operating simultane-
mensioned omnipolar switch with 3 mm minimum opening
ously with an open fireplace or burner that depend on the air
between contacts must be fitted between the appliance and
in the environment and are supplied by other than electrical
the electricity supply in compliance with the load and current
energy, as the cooker hood removes the air from the environ-
regulations.
ment which a burner or fireplace need for combustion. The
- The connection to the mains is carried out as follows:
negative pressure in the environment must not exceed 4Pa
BROWN = L line
(4x10-5 bar). Provide adequate ventilation in the environment
BLUE = N neutral.
for a safe operation of the cooker hood. Follow the local laws
applicable for external air evacuation.
If the hob is electric, gas, or induction, the minimum distance
between the same and the lower part of the hood must be at
least 65 cm. If a connection tube composed of two parts is
- Control the data plate (positioned inside the appliance)
used, the upper part must be placed outside the lower part. Do
to ascertain that the voltage and power correspond to the
not connect the cooker hood exhaust to the same conductor
network and the socket is suitable. If in doubt ask a qualified
used to circulate hot air or for evacuating fumes from other
electrician.
appliances generated by other than an electrical source.
- If the power supply cable is damaged, it must be replaced with
- In the case of assembly of the appliance in the suction version
another cable or a special assembly, which may be obtained
prepare the hole for evacuation of the air.
direct from the manufacturer or from the Technical Assistance
Centre.
We recommend the use of an air exhaust tube which has the
- This device must be connected to the supply network through
same diameter as the air exhaust outlet hole. If a pipe with a
either a plug fused 3A or hardwired to a 2 fase spur protected
smaller diameter is used, the efficiency of the product may be
by 3A fuse.
reduced and its operation may become noisier.
2. Warning!
If your appliance has been designed for use in habitations
supplied with acentralised suction device perform the follow-
danger hazard.
ing operations:
A) Do not check the status of the filters while the cooker
- The switch controls opening and closure of a valve using
hood is operating.
a thermoelectical device. By placing the switch in the ON
B) Do not touch bulbs or adjacent areas, during or straight
position, after a minute, the valve opens rotating 90° allow-
after prolonged use of the lighting installation.
ing suction of the stale air. By placing the switch in the OFF
C) Flambè cooking is prohibited underneath the cooker
position, the valve closes after 100 seconds.
hood.
D) Avoid free flame, as it is damaging for the filters and a
if the bulbs are not working, ensure that they are
fire hazard.
screwed in fully.
-
Prior to proceeding with the assembly operations (according
to the model that you have purchased), to facilitate handling
or infirm persons without supervision.
of the device, remove the grille as indicated in figure 6 or the
aluminium panels as indicated in figure 7.
I) There shall be adequate ventilation of the room when
The appliance is equipped with 2 air outlets, to be used in
the rangehood is used at the same time as appliances
accordance with your specific requirements: one is located
burning gas or other fuels.
on the upper part of the appliance and the other at the rear
L) There is a risk of fire if cleaning is not carried out in
(Fig.1A).
accordance with the instructions.
The flange D, to which the air exhaust pipe is connected, and
a plug B, used to shut off the unused air outlet, are both sup-
This appliance conforms to the European Directive EC/2002/96,
plied with the product.
Waste Electrical and Electronic Equipment (WEEE). By making
sure that this appliance is disposed of in a suitable manner, the
This device may be installed in two different ways:
user is helping to prevent potential damage to the environ-
ment or to public health.
(Fig.2):
- Make 4 holes in the wall cabinet respecting the measurements
The symbol on the product or on the accompanying
indicated in figures 2A-2C.
paperwork indicates that the appliance should not be
- Position the hood underneath the wall cabinet and fix it into
treated as domestic waste, but should be delivered to
place using 4 screws (not supplied) suitable for the type of
a suitable electric and electronic appliance recycling collection
cabinet.
point. Follow local guidelines when disposing of waste. For
more information on the treatment, re-use and recycling of
- 11 -