TECHNICAL DATA Caulking Gun

C18 PCG

Store the battery packs in a 30% - 50% charged condition

SYMBOLS

Every six months of storage, charge the pack as normal.

Feed force ..............................................................................

.......................4500 N

Battery voltage........................................................................

...........................18 V

BATTERY PACK PROTECTION LI-ION BATTERY

Please read the instructions carefully before

Weight according EPTA-Procedure 01/2003 (1,5 Ah) ............

..........................2,3 kg

starting the machine.

Weight according EPTA-Procedure 01/2003 (3,0 Ah) ............

..........................2,5 kg

The battery pack has overload protection that protects it

from being overloaded and helps to ensure long life.

Noise/vibration information

Under extreme stress the battery electronics switch off the

Measured values determined according to EN 60 745.

machine automatically. To restart, switch the machine off

Always wear goggles when using the machine.

Typically, the A-weighted noise levels of the tool are:

and then on again. If the machine does not start up again,

Sound pressure level (K = 3 dB(A)) ......................................

...........................68 dB (A)

the battery pack may have discharged completely. In this

Sound power level (K = 3 dB(A)) ...........................................

...........................79 dB (A)

case it must be recharged in the battery charger.

Total vibration values (vector sum in the three axes)

ADVICE FOR OPERATION

determined according to EN 60745.

2

Remove the battery pack before starting any

Vibration emission value a

....................................................

.......................< 2,5 m/s

Anti-Drip and Rod Release

h

2

work on the machine.

Uncertainty K= ........................................................................

..........................1,5 m/s

The caulk gun features an automatic anti-drip to prevent

drips after the trigger is released. When the trigger is

released, the motor will run for a short time to release the

Do not dispose of electric tools together with

WARNING

rod.

household waste material! In observance of

The vibration emission level given in this information sheet has been measured in accordance with a standardised test given in

When a tube is emptied, the motor will run for a short time to

European Directive 2002/96/EC on waste

EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.

release the rod, then shut off. Release the trigger and

electrical and electronic equipment and its

change the tube.

implementation in accordance with national

The declared vibration emission level represents the main applications of the tool. However if the tool is used for different

law, electric tools that have reached the end of

applications, with different accessories or poorly maintained, the vibration emission may differ. This may signicantly increase

Overload

their life must be collected separately and

the exposure level over the total working period.

When an overload occurs, the tool will reach the maximum

returned to an environmentally compatible

drive force and continue to hold this maximum force until the

An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or when

recycling facility.Opime ampro, qua poressula

user releases the trigger. If material is not dispensing, make

it is running but not actually doing the job. This may signicantly reduce the exposure level over the total working period.

mant.

sure that:

Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the

Nozzle tip is cut

accessories, keep the hands warm, organisation of work patterns.

Inner seal in the caulk tube is broken

Hardened material is removed from the nozzle

Caulk tube is not damaged or frozen

Rod is free of caulk/adhesive materials

EC-DECLARATION OF CONFORMITY

WARNING! Read all safety warnings and all

instructions, including those given in the accompanying

We declare under our sole responsibility that this product

MAINTENANCE

brochure. Failure to follow the warnings and instructions

is in conformity with the following standards or

CAUTION! Carriage and rod must remain clean and free of

may result in electric shock, re and/or serious injury.

standardized documents.

caulk and adhesive materials. Clean off materials

Save all warnings and instructions for future reference.

EN 60745-1:2009 + A11:2010

according to caulk/adhesive manufacturer’s

EN 55014-1:2006 + A1:2009 + A2:2011

recommendations.

SAFETY INSTRUCTIONS

EN 55014-2:1997 + A1:2001 + A2:2008

EN 61000-3-2:2006 + A1:2009 + A2:2009

Use only Milwaukee accessories and Milwaukee spare

Read and understand the charger operator‘s manual

EN 61000-3-3:2008

parts. Should components need to be replaced which have

packaged with your charger.

in accordance with the regulations

not been described, please contact one of our Milwaukee

service agents (see our list of guarantee/service

Always wear goggles when using the machine.

2011/65/EU (RoHs)

2006/42/EC

addresses).

Remove the battery pack before starting any work on the

2004/108/EC

If needed, an exploded view of the tool can be ordered.

machine.

Please state the Article No. as well as the machine type

Do not dispose of used battery packs in the household

printed on the label and order the drawing at your local

refuse or by burning them. Milwaukee Distributors offer to

service agents or directly at: Milwaukee Electric Tool,

retrieve old batteries to protect our environment.

Max-Eyth-Straße 10, D-71364 Winnenden, Germany.

Winnenden, 2012-07-30

Do not store the battery pack together with metal objects

(short circuit risk).

Use only System C18 chargers for charging System C18

battery packs. Do not use battery packs from other

Rainer Kumpf

systems.

Director Product Development

Never break open battery packs and chargers and store

Authorized to compile the technical le

only in dry rooms. Keep dry at all times.

To reduce the risk of injury, electric shock, and damage to

BATTERIES

the tool, never immerse your tool in liquid or allow a liquid

to ow inside the tool.

New battery packs reach full loading capacity after 4 - 5

chargings and dischargings. Battery packs which have not

been used for some time should be recharged before use.

SPECIFIED CONDITIONS OF USE

Temperatures in excess of 50°C (122°F) reduce the

The caulking gun is intended to apply tube or sausage

performance of the battery pack. Avoid extended exposure

pack caulks and adhesives to surfaces.In case of doubt,

to heat or sunshine (risk of overheating).

please read the caulk or adhesive manufacturers‘

instructions.

The contacts of chargers and battery packs must be kept

clean.

Do not use this product in any other way as stated for

normal use.

For an optimum life-time, the battery packs have to be fully

charged, after used.

To obtain the longest possible battery life remove the battery

pack from the charger once it is fully charged.

For battery pack storage longer than 30 days:

Store the battery pack where the temperature is below 27°C

and away from moisture

18 19

ENGLISH ENGLISH