TECHNICAL DATA Cordless percussion drill/driver

C 12 PD

EC-DECLARATION OF CONFORMITY

SYMBOLS

We declare under our sole responsibility that this product is

Drilling capacity in steel ...........................................................

...........................10 mm

in conformity with the following standards or standardized

Please read the instructions carefully before

Drilling capacity in wood ..........................................................

...........................16 mm

documents.

starting the machine.

Drilling capacity in brick and tile ..............................................

...........................10 mm

EN 60745-1:2009 + A11:2010

Wood screws (without pre-drilling) ..........................................

.............................6 mm

EN 60745-2-1:2010

-1

No-load speed 1st gear ...........................................................

......................0-400 min

EN 55014-1:2006 + A1:2009 + A2:2011

-1

No-load speed 2nd gear ..........................................................

....................0-1500 min

EN 55014-2:1997 + A1:2001 + A2:2008

Remove the battery pack before starting any

-1

Percussion rate........................................................................

.....................22500 min

in accordance with the regulations

work on the machine.

Torque max (Li-Ion Battery 1.5 Ah) *1 .....................................

...........................32 Nm

2011/65/EU (RoHs)

Torque max (Li-Ion Battery 3.0 Ah) *1 .....................................

...........................40 Nm

2006/42/EC

Battery voltage.........................................................................

...........................12 V

2004/108/EC

Drill chuck range ......................................................................

........................1-10 mm

Do not dispose of electric tools together with

Weight according EPTA-Procedure 01/2003 ...........................

..........................1,3 kg

household waste material! In observance of

European Directive 2002/96/EC on waste

electrical and electronic equipment and its

Winnenden, 2012-08-02

Noise/vibration information

implementation in accordance with national law,

Measured values determined according to EN 60 745.

electric tools that have reached the end of their

Typically, the A-weighted noise levels of the tool are:

life must be collected separately and returned to

Sound pressure level (K = 3 dB(A)) .......................................

........................90,5 dB (A)

an environmentally compatible recycling facility.

Sound power level (K = 3 dB(A)) ............................................

......................101,5 dB (A)

Rainer Kumpf

Wear ear protectors!

Director Product Development

Authorized to compile the technical le

Total vibration values (vector sum in the three axes)

determined according to EN 60745.

BATTERIES

Vibration emission value a

h

2

Percussion drilling into concrete ...........................................

........................13,6 m/s

New battery packs reach full loading capacity after 4 - 5

2

Uncertainty K= ......................................................................

..........................1,5 m/s

chargings and dischargings. Battery packs which have not

2

Drilling into metal ..................................................................

.......................< 2,5 m/s

been used for some time should be recharged before use.

2

Uncertainty K= ......................................................................

..........................1,5 m/s

2

Temperatures in excess of 50°C (122°F) reduce the

Screwing ...............................................................................

.......................< 2,5 m/s

2

performance of the battery pack. Avoid extended exposure

Uncertainty K= ......................................................................

..........................1,5 m/s

to heat or sunshine (risk of overheating).

*1 Measured according to Milwaukee Standard N 877318

The contacts of chargers and battery packs must be kept

clean.

WARNING

For an optimum life-time, after use, the battery packs have

to be fully charged.

The vibration emission level given in this information sheet has been measured in accordance with a standardised test given

in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.

To obtain the longest possible battery life remove the battery

pack from the charger once it is fully charged.

The declared vibration emission level represents the main applications of the tool. However if the tool is used for different

applications, with different accessories or poorly maintained, the vibration emission may differ. This may signicantly increase

For battery pack storage longer than 30 days:

the exposure level over the total working period.

Store the battery pack where the temperature is below 27°C

and away from moisture

An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or

Store the battery packs in a 30% - 50% charged condition

when it is running but not actually doing the job. This may signicantly reduce the exposure level over the total working period.

Every six months of storage, charge the pack as normal.

Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the

accessories, keep the hands warm, organisation of work patterns.

BATTERY PACK PROTECTION

In extremely high torque, binding, stalling and short circuit

situations that cause high current draw, the tool will vibrate

for about 5 seconds, the fuel gauge will ash,and then the

tool will turn OFF. To reset, release the trigger.

Under extreme circumstances, the internal temperature of

WARNING! Read all safety warnings and all

Remove the battery pack before starting any work on the

the battery pack could raise too much. If this happens, the

instructions, including those given in the accompanying

machine.

fuel gauge will ash until the battery pack cooled down. After

brochure. Failure to follow the warnings and instructions

Do not dispose of used battery packs in the household

the lights go off, the work may continue.

may result in electric shock, re and/or serious injury.

refuse or by burning them. Milwaukee Distributors offer to

Save all warnings and instructions for future reference.

retrieve old batteries to protect our environment.

MAINTENANCE

Do not store the battery pack together with metal objects

SAFETY INSTRUCTIONS FOR ROTARY DRILLS

Use only Milwaukee accessories and spare parts. Should

(short circuit risk).

components need to be replaced which have not been

Wear ear protectors. Exposure to noise can cause hearing

Use only System C 12 chargers for charging System C 12

described, please contact one of our Milwaukee service

loss.

battery packs. Do not use battery packs from other systems.

agents (see our list of guarantee/service addresses).

Hold power tool by insulated gripping surfaces, when

Battery acid may leak from damaged batteries under

If needed, an exploded view of the tool can be ordered.

performing an operation where the cutting accessory

extreme load or extreme temperatures. In case of contact

Please state the Article No. as well as the machine type

may contact hidden wiring. Cutting accessory contacting

with battery acid wash it off immediately with soap and

printed on the label and order the drawing at your local

a „live“ wire may make exposed metal parts of the power

water. In case of eye contact rinse thoroughly for at least 10

service agents or directly at: Milwaukee Electric Tool,

tool „live“ and could give the operator an electric shock.

minutes and immediately seek medical attention.

Max-Eyth-Straße 10, D-71364 Winnenden, Germany.

Hold power tool by insulated gripping surfaces, when

performing an operation where the fastener may

SPECIFIED CONDITIONS OF USE

contact hidden wiring. Fasteners contacting a "live" wire

The electronic battery percussion drill/screwdriver may be

may make exposed metal parts of the power tool "live" and

used for drilling, percussion drilling, as well as screwdriving

could give the operator an electric shock.

for independent use away from mains supply.

Sawdust and splinters must not be removed while the

Do not use this product in any other way as stated for

machine is running.

normal use.

When working in walls ceiling, or oor, take care to avoid

electric cables and gas or waterpipes.

16 17

ENGLISH

ENGLISH