Milwaukee C12 PD: 16 17 ENGLISH ENGLISH
16 17 ENGLISH ENGLISH: Milwaukee C12 PD
TECHNICAL DATA Cordless percussion drill/driver
C 12 PD
EC-DECLARATION OF CONFORMITY
SYMBOLS
We declare under our sole responsibility that this product is
Drilling capacity in steel ...........................................................
...........................10 mm
in conformity with the following standards or standardized
Please read the instructions carefully before
Drilling capacity in wood ..........................................................
...........................16 mm
documents.
starting the machine.
Drilling capacity in brick and tile ..............................................
...........................10 mm
EN 60745-1:2009 + A11:2010
Wood screws (without pre-drilling) ..........................................
.............................6 mm
EN 60745-2-1:2010
-1
No-load speed 1st gear ...........................................................
......................0-400 min
EN 55014-1:2006 + A1:2009 + A2:2011
-1
No-load speed 2nd gear ..........................................................
....................0-1500 min
EN 55014-2:1997 + A1:2001 + A2:2008
Remove the battery pack before starting any
-1
Percussion rate........................................................................
.....................22500 min
in accordance with the regulations
work on the machine.
Torque max (Li-Ion Battery 1.5 Ah) *1 .....................................
...........................32 Nm
2011/65/EU (RoHs)
Torque max (Li-Ion Battery 3.0 Ah) *1 .....................................
...........................40 Nm
2006/42/EC
Battery voltage.........................................................................
...........................12 V
2004/108/EC
Drill chuck range ......................................................................
........................1-10 mm
Do not dispose of electric tools together with
Weight according EPTA-Procedure 01/2003 ...........................
..........................1,3 kg
household waste material! In observance of
European Directive 2002/96/EC on waste
electrical and electronic equipment and its
Winnenden, 2012-08-02
Noise/vibration information
implementation in accordance with national law,
Measured values determined according to EN 60 745.
electric tools that have reached the end of their
Typically, the A-weighted noise levels of the tool are:
life must be collected separately and returned to
Sound pressure level (K = 3 dB(A)) .......................................
........................90,5 dB (A)
an environmentally compatible recycling facility.
Sound power level (K = 3 dB(A)) ............................................
......................101,5 dB (A)
Rainer Kumpf
Wear ear protectors!
Director Product Development
Authorized to compile the technical le
Total vibration values (vector sum in the three axes)
determined according to EN 60745.
BATTERIES
Vibration emission value a
h
2
Percussion drilling into concrete ...........................................
........................13,6 m/s
New battery packs reach full loading capacity after 4 - 5
2
Uncertainty K= ......................................................................
..........................1,5 m/s
chargings and dischargings. Battery packs which have not
2
Drilling into metal ..................................................................
.......................< 2,5 m/s
been used for some time should be recharged before use.
2
Uncertainty K= ......................................................................
..........................1,5 m/s
2
Temperatures in excess of 50°C (122°F) reduce the
Screwing ...............................................................................
.......................< 2,5 m/s
2
performance of the battery pack. Avoid extended exposure
Uncertainty K= ......................................................................
..........................1,5 m/s
to heat or sunshine (risk of overheating).
*1 Measured according to Milwaukee Standard N 877318
The contacts of chargers and battery packs must be kept
clean.
WARNING
For an optimum life-time, after use, the battery packs have
to be fully charged.
The vibration emission level given in this information sheet has been measured in accordance with a standardised test given
in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.
To obtain the longest possible battery life remove the battery
pack from the charger once it is fully charged.
The declared vibration emission level represents the main applications of the tool. However if the tool is used for different
applications, with different accessories or poorly maintained, the vibration emission may differ. This may signicantly increase
For battery pack storage longer than 30 days:
the exposure level over the total working period.
Store the battery pack where the temperature is below 27°C
and away from moisture
An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or
Store the battery packs in a 30% - 50% charged condition
when it is running but not actually doing the job. This may signicantly reduce the exposure level over the total working period.
Every six months of storage, charge the pack as normal.
Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the
accessories, keep the hands warm, organisation of work patterns.
BATTERY PACK PROTECTION
In extremely high torque, binding, stalling and short circuit
situations that cause high current draw, the tool will vibrate
for about 5 seconds, the fuel gauge will ash,and then the
tool will turn OFF. To reset, release the trigger.
Under extreme circumstances, the internal temperature of
WARNING! Read all safety warnings and all
Remove the battery pack before starting any work on the
the battery pack could raise too much. If this happens, the
instructions, including those given in the accompanying
machine.
fuel gauge will ash until the battery pack cooled down. After
brochure. Failure to follow the warnings and instructions
Do not dispose of used battery packs in the household
the lights go off, the work may continue.
may result in electric shock, re and/or serious injury.
refuse or by burning them. Milwaukee Distributors offer to
Save all warnings and instructions for future reference.
retrieve old batteries to protect our environment.
MAINTENANCE
Do not store the battery pack together with metal objects
SAFETY INSTRUCTIONS FOR ROTARY DRILLS
Use only Milwaukee accessories and spare parts. Should
(short circuit risk).
components need to be replaced which have not been
Wear ear protectors. Exposure to noise can cause hearing
Use only System C 12 chargers for charging System C 12
described, please contact one of our Milwaukee service
loss.
battery packs. Do not use battery packs from other systems.
agents (see our list of guarantee/service addresses).
Hold power tool by insulated gripping surfaces, when
Battery acid may leak from damaged batteries under
If needed, an exploded view of the tool can be ordered.
performing an operation where the cutting accessory
extreme load or extreme temperatures. In case of contact
Please state the Article No. as well as the machine type
may contact hidden wiring. Cutting accessory contacting
with battery acid wash it off immediately with soap and
printed on the label and order the drawing at your local
a „live“ wire may make exposed metal parts of the power
water. In case of eye contact rinse thoroughly for at least 10
service agents or directly at: Milwaukee Electric Tool,
tool „live“ and could give the operator an electric shock.
minutes and immediately seek medical attention.
Max-Eyth-Straße 10, D-71364 Winnenden, Germany.
Hold power tool by insulated gripping surfaces, when
performing an operation where the fastener may
SPECIFIED CONDITIONS OF USE
contact hidden wiring. Fasteners contacting a "live" wire
The electronic battery percussion drill/screwdriver may be
may make exposed metal parts of the power tool "live" and
used for drilling, percussion drilling, as well as screwdriving
could give the operator an electric shock.
for independent use away from mains supply.
Sawdust and splinters must not be removed while the
Do not use this product in any other way as stated for
machine is running.
normal use.
When working in walls ceiling, or oor, take care to avoid
electric cables and gas or waterpipes.
16 17
ENGLISH
ENGLISH
Оглавление
- 2 3
- 4 5
- 6 7
- 8 9
- 10 11
- 12 13
- 14 15
- 16 17 ENGLISH ENGLISH
- 18 19 DEUTSCH DEUTSCH
- 20 21 FRANÇAIS FRANÇAIS
- 22 23 ITALIANO ITALIANO
- 24 25 ESPAÑOL ESPAÑOL
- 26 27 PORTUGUES PORTUGUES
- 28 29 NEDERLANDS NEDERLANDS
- 30 31 DANSK DANSK
- 32 33 NORSK NORSK
- 34 35 SVENSKA SVENSKA
- 36 37 SUOMI SUOMI
- 38 39 ÅËËÇNÉÊÁ ÅËËÇNÉÊÁ
- 40 41 TÜRKÇE TÜRKÇE
- 42 43 ČESKY ČESKY
- 44 45
- 46 47 POLSKI POLSKI
- 48 49 MAGYAR MAGYAR
- 50 51 SLOVENSKO SLOVENSKO
- 52 53 HRVATSKI HRVATSKI
- 54 55 LATVISKI LATVISKI
- 56 57
- 58 59 EESTI EESTI
- 60 61 ÐÓÑÑÊÈÉ ÐÓÑÑÊÈÉ
- 62 63 БЪЛГАÐÑÊÈ БЪЛГАÐÑÊÈ
- 64 65 ROMÂNIA ROMÂNIA
- 66 67 МАКЕДОНСКИ МАКЕДОНСКИ
- 68 69 中文 中文