5. Mounting the appliance
5.1 Application
One appliance can be used for the following applications:
one or multiple hand washing sinks
one kitchen sink
cabins with flow restriction at shower head.
A combination of two appliance can be used for whole apartment
and house applications. Please contact STIEBEL ELTRON for special
installation instructions.
All areas with a ground water temperature likely to exceed 65 °F
(18 °C) year round:
Whole apartment or house
CAUTION Electrocution
Unit must be installed in a vertical position with the
water fittings pointing downward. In this position the
unit is splashproof, so that no water can soak in.
1
2
3
4
5
6
7
26
_0
2
_02
_1
0
8
2
1
2
3
4
5
6
7
26
_0
2
_02
_1
0
8
1
1 Hot valve (left)
2 Cold valve (right)
3 Sink
4 1/2“ main pipe
5 Water supply line for faucet installation
6 Shut-off valve
7 Electrical junction box
5.2 Mounting
f
Install appliance as close as possible to the main hot water
draw-off points.
f
Install appliance in a frost free area. If frost may occur, re-
move appliance before freezing temperatures set in.
f
Leave a minimum of 5“ of clearance on all sides for servicing.
2
6
_0
2_0
2
_1
0
8
3
f
Remove plastic cover.
2
6
_0
2_0
2
_0
3
3
1
2
6
_0
2_0
2_
1
0
9
0
f
Screw the screws into the wall and hang the appliance.
Screws and plastic wall anchors for mounting on masonry or
wood are provided.
f
Secure the screws.
5.3 Water
connections
Damage to the appliance and the environment
Excessive heat from soldering on copper pipes near the
DHC may cause damage.

ō
+é
qqqĪZ`.<é<`VHCĪHB
.CZ`<<`.HC <`V.<HCC`.HC
f
All plumbing work must comply with national and applicable
state and local plumbing codes.
f
Notice for Australia / New Zealand:
The installation shall comply with AS/NZS 3500.4.
f
A pressure reducing valve must be installed if the cold water
supply pressure exceeds 150 PSI (10 bar).
f
Make certain that the cold water supply line has been flushed
to remove any scale and dirt.
f
Install isolating valve in cold water line as shown in illustra-
tion “Mounting the appliance”. This allows the appliance to
be isolated for maintenance purposes.
f
Cold water connection (inlet) is on the right side of the ap-
pliance, hot water connection (outlet) is on the left side of
appliance.
f
Tankless water heaters such as the DHC-E are not required to
be equipped with a Pressure and Temperature Relief Valve
(P&T). If the local inspector will not pass the installation
without a P&T, it should be installed on the hot water outlet
side of appliance.
f
The appliance is designed for connection to copper tubing,
PEX tubing or a braided stainless steel hose with a ½“ NPT
female tapered thread. If soldering near the appliance is nec-
essary, please direct the flame away from the plastic housing
of the appliance in order to avoid damage.
f
When all plumbing work is completed, check for leaks and
take corrective action before proceeding.
6. Electrical connection
DANGER Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
DANGER Electrocution
Only use a permanent connection to the power supply.
The appliance must be able to be separated from the
power supply by an isolator that disconnects all poles
with at least 3 mm contact separation.
Damage to the appliance and the environment
Observe the type plate. The specified voltage must match
the mains voltage.
DANGER Electrocution
Before beginning any work on the electric installation,
be sure that main breaker panel switch is „off“ to
avoid any danger of electric shock. All mounting and
plumbing must be completed before proceeding with
electrical hook-up. Where required by local, state or
national electrical codes the circuit should be equipped
with a „ground fault interrupter“.
DANGER Electrocution
As with any electric appliance. failure to electrically
ground appliance may result in serious injury or death.
f
The appliance should be connected to a properly grounded
dedicated branch circuit of proper voltage rating. In installa-
tions with several appliances, each appliance requires an
independent circuit. Please refer to the technical data table
for the correct wire and circuit breaker size.
26
_0
2
_02
_1
0
8
4
f
The wire must be fed through the rubber seal located be-
tween the hot and cold water connections. Then feed wires
through strain relief clamp and tighten clamp down on wire.
The „live“ wires must be connected to the slots on the ter-
minal block marked L and L (L and N). The ground wire must
be connected to slot marked with the ground symbol. Strain
relief clamp with screws and rubber seal are provided.
6.1
DHC-E 8/10 - Appliance with output power op-
tions
For the DHC-E 8/10 instantaneous water heater, the output power
is adjustable in 2 stages. In its delivered condition the appliance
is set to 7.2 kW @ 240 V.
1
26
_0
2
_02
_1
0
8
8
1 coding plug
If the appliance should be installed with a different output power,
take the following steps:
f
Insert the coding plug to the desired performance.
ZŒ|Ö¼Ĝ
ŝƃÄp
ŝŝƃp
ŝŗƃp
ŝÔƃp
5,4 kW
6,0 kW
6,6 kW
7,2 kW
ZŒ|Ö¼ŝ
ŝƃÄp
ŝŝƃp
ŝŗƃp
ŝÔƃp
7,2 kW
8,1 kW
8,8 kW
9,6 kW
f
Mark the selected output power and voltage on the type
plate
with a permanent marker.

EN
GL
ISH
qqqĪZ`.<é<`VHCĪHB
+é
Ō
.CZ`<<`.HC HBB.ZZ.HC.C&
6.2
Temperature setting/anti-scalding protection
26
_0
2
_02
_1
0
8
9
f
Connect the lead of the electronic temperature control
to position „A1“ in order to get the maximum outlet
temperature of 140 °F (60 °C).
The maximum temperature can be limited to 109 °F (43 °C):
f
Connect the lead of the electronic temperature control to po-
sition „A2“.
f
Reinstall the plastic cover.
7. Commissioning
DANGER Electrocution
Commissioning must only be carried out by an author-
ised contractor in accordance with safety regulations.
Damage to the appliance and the environment
Open hot water faucet for a few minutes until water flow
is continuous and all air is purged from water pipes. The
appliance’s plastic cover must be installed before the
circuit breaker is turned on.
f
Turn on circuit breaker to bring electrical power to the
appliance.
f
Turn the temperature selector clockwise and anti-clockwise,
to calibrate the temperatur selector.
f
Adjust the water temperature to the desired level using the
knob on the front cover of the appliance.
f
Turn on hot water and wait twenty seconds until temperature
has stabilized.
f
Check the water temperature with your hand and make sure
that it does not feel too hot. Reduce temperature if this is
necessary. A setting of 108 °F - 116 °F (42 - 47 °C) is recom-
mended for most applications.
f
Explain to the user how the appliance works and familiarise
him or her with its use.
f
Advise the user about possible hazards (hot water tempera-
ture up to 140 °F (60 °C). Hand over these instructions, to be
kept for future reference.
f
A setting of 108 °F - 116 °F (42 - 47 °C) is recommended for
most applications.
7.1 Appliance
handover
Explain the functions of the appliance to the user. Draw special
attention to the safety information. Hand the operating and instal-
lation instructions to the user.
8. Troubleshooting
Danger of electrocution
To test the appliance, it must be supplied with power.
8.1
Display options LED diagnostic „traffic lights“
êńĤù|źĒĤŒêĒĉń
red
illuminates in case of faults
yellow
illuminates when the appliance is heating water
green
flashing: The appliance is supplied with power
1
26
_0
2
_02
_1
0
8
8
1 LED diagnostic „traffic lights“
8.2 Fault
table
ZźăĤŒĒă
TĒńńêù¼|şń¼
f
ZĒùşŒêĒĉ
No hot water
circuit breaker off
safety thermal cut-out
tripped
turn circuit breaker on
reset thermal cut-out
not enough flow rate to
activate appliance
clean filter screen at
appliance
clean faucet aerator or
shower head
Not enough hot water filter screen clogged
clean filter screen at
appliance
Water not hot enough
water flow too high
reduce water flow rate until
light on front cover stops
blinking
supply correct voltage to
appliance
f
If you are not able to resolve a problem please contact us,
see last side, before removing the appliance from the wall.
STIEBEL ELTRON is happy to provide technical assistance. In
most instances, we can resolve the problem over the phone.
9. Normal maintenance
STIEBEL ELTRON tankless water heaters are designed for a very
long service life. Actual life expectancy will vary with water qual-
ity and use. The appliance itself does not require any regular
maintenance.

Ä
+é
qqqĪZ`.<é<`VHCĪHB
.CZ`<<`.HC `+C.<`
However, to ensure consistent water flow, it is recommended to
periodically remove scale and dirt that may build up at the aera-
tor of the faucet(s), the filter screen in the appliance, or in the
shower head.
10. Technical Data
10.1 Dimensioned
drawing
E
F
F
F
F
D00000
1
7
7
6
2
b01 Electrical cable entry
c01
cold water inlet
"NPT
1/2
c06
hot water outlet
"NPT
1/2
10.2 Wiring
diagram
+éÄŎĜƃ
2/GRD ~ 208 / 240 V
1/N/PE ~ 220 / 230 / 240 V
8
5
_0
2_0
3_000
1
+éĜŝ
2/GRD ~ 208 / 240 V
1/N/PE ~ 220 / 230 / 240 V
8
5
_0
2_0
3_000
2

EN
GL
ISH
qqqĪZ`.<é<`VHCĪHB
+é
Ď
.CZ`<<`.HC `+C.<`
10.3 Maximum temperature increase above ambient water temperature
Warm water flow rate [ GPM ]
q|ļăŷ|Œ¼ļĒşŒù¼ŒŒ¼ăĤ¼ļ|Œşļ¼ĜƃÔ³%
Cold water inlet temperature
°F
39
50
59
68
77
86
95
104
113
122
131
DHC-E 8/10
5.4 kW @ 208 V
0.57
0.68
0.82
1.02
1.36
2.04
4.09
-
-
-
-
7.2 kW @ 240 V
0.76
0.91
1.09
1.36
1.82
2.72
5.45
-
-
-
-
7.2 kW @ 208 V
0.76
0.91
1.09
1.36
1.82
2.72
5.45
-
-
-
-
9.6 kW @ 240 V
1.01
1.21
1.45
1.82
2.42
3.63
6.61
-
-
-
-
DHC-E 12
9 kW @ 208 V
0.95
1.14
1.36
1.70
2.27
3.23
6.47
-
-
-
-
12 kW @ 240 V
1.26
1.51
1.82
2.27
3.03
4.31
6.61
-
-
-
-
q|ļăŷ|Œ¼ļĒşŒù¼ŒŒ¼ăĤ¼ļ|Œşļ¼ĜĜŗ³%
Cold water inlet temperature
°F
39
50
59
68
77
86
95
104
113
122
131
DHC-E 8/10
5.4 kW @ 208 V
0.50
0.58
0.68
0.82
1.02
1.36
2.04
4.09
-
-
-
7.2 kW @ 240 V
0.66
0.78
0.91
1.09
1.36
1.82
2.72
5.45
-
-
-
7.2 kW @ 208 V
0.66
0.78
0.91
1.09
1.36
1.82
2.72
5.45
-
-
-
9.6 kW @ 240 V
0.89
1.04
1.21
1.45
1.82
2.42
3.63
6.61
-
-
-
DHC-E 12
9 kW @ 208 V
0.83
0.97
1.14
1.36
1.70
2.16
3.23
6.47
-
-
-
12 kW @ 240 V
1.11
1.30
1.51
1.82
2.27
2.88
4.31
6.61
-
-
-
q|ļăŷ|Œ¼ļĒşŒù¼ŒŒ¼ăĤ¼ļ|Œşļ¼ĜÔƃ³%
Cold water inlet temperature
°F
39
50
59
68
77
86
95
104
113
122
131
DHC-E 8/10
5.4 kW @ 208 V
0.36
0.41
0.45
0.51
0.58
0.68
0.82
1.02
1.36
2.04
4.09
7.2 kW @ 240 V
0.49
0.54
0.61
0.68
0.78
0.91
1.09
1.36
1.82
2.72
5.45
7.2 kW @ 208 V
0.49
0.54
0.61
0.68
0.78
0.91
1.09
1.36
1.82
2.72
5.45
9.6 kW @ 240 V
0.65
0.73
0.81
0.91
1.04
1.21
1.45
1.82
2.42
3.63
6.61
DHC-E 12
9 kW @ 208 V
0.61
0.68
0.76
0.85
0.97
1.08
1.29
1.62
2.16
3.23
6.47
12 kW @ 240 V
0.81
0.91
1.01
1.14
1.30
1.44
1.73
2.16
2.88
4.31
6.61
Warm water flow rate [ l/min ]
q|ļăŷ|Œ¼ļĒşŒù¼ŒŒ¼ăĤ¼ļ|Œşļ¼Ôƃ³
Cold water inlet temperature
°C
4
10
15
20
25
30
35
40
45
50
55
DHC-E 8/10
5.4 kW @ 208 V
2.15
2.58
3.09
3.87
5.16
7.73
15.47
-
-
-
-
7.2 kW @ 240 V
2.86
3.44
4.12
5.16
6.87
10.31
20.62
-
-
-
-
7.2 kW @ 208 V
2.86
3.44
4.12
5.16
6.87
10.31
20.62
-
-
-
-
9.6 kW @ 240 V
3.82
4.58
5.50
6.87
9.16
13.75
25.00
-
-
-
-
DHC-E 12
9 kW @ 208 V
3.58
4.30
5.16
6.44
8.59
12.24
24.49
-
-
-
-
12 kW @ 240 V
4.77
5.73
6.87
8.59
11.46
16.32
25.00
-
-
-
-
q|ļăŷ|Œ¼ļĒşŒù¼ŒŒ¼ăĤ¼ļ|Œşļ¼Ôѳ
Cold water inlet temperature
°C
4
10
1
20
25
30
35
40
45
50
55
DHC-E 8/10
5.4 kW @ 208 V
1.89
2.21
2.58
3.09
3.87
5.16
7.73
15.47
-
-
-
7.2 kW @ 240 V
2.51
2.95
3.44
4.12
5.16
6.87
10.31
20.62
-
-
-
7.2 kW @ 208 V
2.51
2.95
3.44
4.12
5.16
6.87
10.31
20.62
-
-
-
9.6 kW @ 240 V
3.35
3.93
4.58
5.50
6.87
9.16
13.75
25.00
-
-
-
DHC-E 12
9 kW @ 208 V
3.14
3.68
4.30
5.16
6.44
8.16
12.24
24.49
-
-
-
12 kW @ 240 V
4.19
4.91
5.73
6.87
8.59
10.88
16.32
25.00
-
-
-
q|ļăŷ|Œ¼ļĒşŒù¼ŒŒ¼ăĤ¼ļ|Œşļ¼ōƃ³
Cold water inlet temperature
°C
4
10
15
20
25
30
35
40
45
50
55
DHC-E 8/10
5.4 kW @ 208 V
1.38
1.55
1.72
1.93
2.21
2.58
3.09
3.87
5.16
7.73
15.47
7.2 kW @ 240 V
1.84
2.06
2.29
2.58
2.95
3.44
4.12
5.16
6.87
10.31
20.62
7.2 kW @ 208 V
1.84
2.06
2.29
2.58
2.95
3.44
4.12
5.16
6.87
10.31
20.62
9.6 kW @ 240 V
2.45
2.75
3.05
3.44
3.93
4.58
5.50
6.87
9.16
13.75
25.00
DHC-E 12
9 kW @ 208 V
2.30
2.58
2.86
3.22
3.68
4.08
4.90
6.12
8.16
12.24
24.49
12 kW @ 240 V
3.07
3.44
3.82
4.30
4.91
5.44
6.53
8.16
10.88
16.32
25.00

Ĝƃ
+é
qqqĪZ`.<é<`VHCĪHB
.CZ`<<`.HC ZTVTV`Z
10.4 Data
table
+éÄŎĜƃ+éĜŝ
Part number
224201
230628
Phase
1
1
1
1
1
1
1
1
1
1
1
1
Voltage
V
208
220
230
240
208
220
230
240
208
220
230
240
Frequency
Hz
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
Coding plug
Position
1
1
1
1
2
2
2
2
-
-
-
-
Output power
kW
5.4
6.0
6.6
7.2
7.2
8.1
8.8
9.6
9
10
11
12
Ampere
A
28
30
31
32
35
37
39
40
44
46
48
50
Min. required circuit breaker size
A
30
40
40
40
50
50
50
50
60
60
60
60
Rocommended wire size
AWG COPPER
10
-
-
8
8
-
-
8
6
-
-
6
Rocommended wire size
mm² COPPER
-
6
6
-
-
10
10
-
-
10
10
-
Protection level according to
IP 24
IP 24
Min. water flow to activate appliance
GPM / l/min
0.37 / 1.4
0.37 / 1.4
Nominal water volume
GAL / l
0.13 / 0.5
0.13 / 0.5
Working pressure max.
PSI / bar / MPa
150 / 10 / 1
150 / 10 / 1
Tested to pressure
PSI / bar / MPa
300 / 20 / 2
300 / 20 / 2
Weight
lbs. / kg
5.9 / 2.7
5.9 / 2.7
Water connections
“ NPT
1/2
1/2
f
Suitable for supply with up to 131 °F / 55 °C
f
Tankless water heaters are considered a non-continuous load
f
&RQGXFWRUVVKRXOGEHVL]HGWRPDLQWDLQDYROWDJHGURSRIOHVV
WKDQXQGHUORDG
11. Spare parts
2
1
13
6
3
5
10
11
15
14
9
8
7
12
2
6
_0
2_0
2_
1
0
9
1
4
CĒĪ CĒĪZĤ|ļ¼Ĥ|ļŒ
+éÄŎĜƃ+éĜŝ
1
Heating system
292575
292576
2
Safety thermal cut out
286369
286369
3
Electronic control appliance
291851
291852
4
Coding plug
283455
---
5
Back panel
292578
292578
6
Flow sensor DFE
286461
286461
7
Cold water connection
291699
291699
8
Filter screen
252430
252430
9
Hot water connection
278634
278634
10
Plastic cover
292577
292577
11
Wiring block
279998
279998
12
Axis connection plug
254312
254312
13
Electronic temperature control
286359
286359
14
Temperature adjustment knob
254307
254307
15
Outlet temperature sensor
280677
280677