Stiebel Eltron SNU 5 SLi 01.05.2007 - 28.10.2007: 1. Operating Instructions

1. Operating Instructions: Stiebel Eltron SNU 5 SLi 01.05.2007 - 28.10.2007

background image

8

1. Operating Instructions

 for the user and engineer

1.1  Description of Unit

•  The open (pressure-less) water heater con-

stantly maintains the water content at the 

preset temperature.

•  The “

thermostop

” function (thermal sepa-

ration) prevents heating of the tempering 

fitting in standby mode.

•  The “antitropf” (anti-drip) function pre-

vents expansion water from penetrating the 

fitting during heating up.

»  When water heats up, gas bubbles form. 

There may be more or less of them de-

pending on the quality of the water. At 

temperatures > 75 °C, residual water 

may drip out of the fitting outlet.

»  Depending on the design type, different 

fittings are inclined to incur subsequent 

dripping after closure. This is residual 

water from the fitting outlet and not ex-

pansion water.

•  Only fittings for open (pressureless) water 

heaters may be installed.

  We recommend Stiebel Eltron fittings: for 

order no. see 1.7 „Special accessories”.

1.2  The most important points  

in brief

•  Set the desired hot water temperature at 

the temperature selector (

1

)

•  The unit is heating when the display (

2

lights.

2

1

C26_07_31_0037

85

°C

35

55

65 Eco

antitropf com

fort

1.3  Operation

Temperature setting

°C

  =  cold. On this setting, the unit, but not 

the fitting or water pipe, is protected 

from frost

Eco

  =  recommended energy-saving setting 

(approx. 60°C), low limescale formati-

on

85

  =  max. temperature setting.

Note:

On request, the engineer can restrict the tem-

perature on the unit (see 2.8 “First Use”) so 

that the temperature can be set anywhere up 

to the temperature limit.

Heating time:

If the entire water content is used, the heating 

time is that shown on the diagram.

  35 °C   

55 °C  E  65 °C 

85 °C

[min]

  15

  10

5

0

2 kW

Example:

Temperature setting: 

65 °C

Heating time: 

approx. 

9.5 minutes

Mixed water quantity:

Using the temperature, you set a mixed water 

quantity for e.g. 40 °C.

[ l ]

15

10

5

0

  40 °C 

55 °C  E  65 °C 

85 °C

Example:

Temperature setting: 

65 °C 

Cold water feed: 

15 °C 

Mixed water quantity: 

approx. 

10 l

1.4  Important Note

• 

The water heater must not be pres-

surized. Never block the fitting outlet 

and do not use a Perlator or hose with jet 

controller. 

• 

If the temperature is set higher than 45 °C, 

very hot water can flow immediately! 

• 

Keep children and the disabled (physical/

mental) away from this unit unless they are 

supervised by a person responsible for their 

safety or have been given instructions on 

how to use it. 

• 

Ensure that children do not adjust the tem-

perature (to a high temperature) on the unit 

when playing - Risk of scalding! 

• 

We recommend the use of the temperature 

restrictor set by the engineer, unless absolu-

tely necessary otherwise. 

• 

To avoid risk of accidental resetting of the 

protective temperature restrictor in the event 

of a fault, the unit must not be connected via 

a timer switch.

Limescale can block the outlet and hence pres-

surize the heater.

Signs of limescale are boiling sounds and 

reduced water flow. In this case have the unit 

and fitting descaled by an engineer

The thermostat knob may only be removed by 

an engineer.

All information in these Operating and In-

stallation Instructions must be observed. The 

instructions contain important information for 

safety, operation and maintenance of the unit.

1.5  Care and Maintenance

To clean the unit, simply wipe with a damp 

cloth. Do not use abrasive or aggressive clea-

ning agents.

Maintenance work should only be 

performed by an engineer.

1.6  What to do if....

...there is no hot water:

Check the thermostat, plug and fuse.

...there is a boiling sound from the unit:

Have the unit and fitting descaled by an en-

gineer.

...see also 3. „Fault repair by the user and 

engineer”.

If an engineer is called for a problem, to help 

him resolve this more quickly and efficiently, 

please give him the information below on the 

unit rating plate (

9

):

Typ:

SNU 5 SL

Nr.: ...... - .... - ......

..............

C26_02_06_0010

1.7  Special accessories

Stiebel Eltron order numbers:

•  Two-handle tempering fittings

  - for bathroom:

  WST-W

  07 44 27

WST

22 24 30

WSM

22 24 31

  - for kitchen:

  WST-K

07 44 28

  WUT

22 24 32

WUM

22 24 33

•  Single lever mixer fittings

  - for bathroom:

  MEW

22 24 39

  - for kitchen:

  MES

22 24 40

  MESB

22 24 41

  MESL

22 24 42

•  Filter for cold-water connection

  Order no. 

27 00 45

•  Electrical connection cable   

Order no. 

02 06 71