Brennenstuhl Moisture Detector MD: Operating Instructions
Operating Instructions: Brennenstuhl Moisture Detector MD

Operating Instructions
INTRODUCTION
This moisture meter is a useful instrument, for determining the
moisture content of wood or construction materials such as concrete,
tile, screed, plaster, carpets, etc. Prior to operational start of the
device, read the following instructions carefully and keep them for
future reference.
Protective cap
Measuring probe
Moisture level indicator:
Low
Middle
Hight
Wood display
Construction materials display
»Acoustic signal on/off« display
On-/off switch: Hold longer than three
seconds to turn on or off.
Low battery indicator
»Hold«-function display to »freeze«
measured values
쐅 Selector button: For switching from
»wood« to »construction materials«
and back
쐈 »Hold«-button: To »freeze« the measu-
red values, press and hold for ca. 1 se-
cond, the next push turns the function
off again. To turn the acoustic signal on
and off, press and hold for longer than
three seconds.
쐉 Battery cover (back)
Operation
Note: Be aware that the probe tip can cause injuries if used incor-
rectly. Put the protective cover back on when the device is not in use.
Keep the moisture meter away from children!
Inserting the Battery:
Remove the battery cover and insert a new battery (9V DC alkaline
block battery). Make sure you connect the poles correctly.
6
1
2
8
3
I
4
5
6
J
G
K
L
007709 Feuchtigkeitsdetector MD_007709 BA_Feuchtigkeitsmesser 27.10.14 16:20 Seite 6

MD Operating Instructions
B
attery indicator:
The battery indicator is displayed when the device is in use. The bat-
tery symbol with two full bars ( ) means the battery is full. The
battery symbol with one full bars and one empty bar ( ) means
the battery is half full. If the battery is empty, the battery symbol
appears with two empty bars ( ) and blinks. The device will then
turn off and the battery must be replaced.
Performing measurements:
1. Remove the protective cover and place it on the
underside of the device.
2.
Press and hold the on/off switch » « until the
display appears in the display window.
Select wood » « or construction materials » « by
pressing the selector button » «.
Insert the probe tip into the material to be tested (e.g.
wood) and read the value in the display window. At the
same time, an acoustic signal should sound. The higher
the tone, the higher the moisture content.
Press the »Hold«-button once » « to »freeze« the
display in the display window. This can be useful if you
wish to perform a reading in conditions of darkness or
poor visibility. The symbol » « will appear in the
display window and the reading will be displayed until
the »Hold«-button » « is pressed again.
Press down the »Hold«-button » « for longer than
3 seconds to turn the acoustic tone on or off.
SAMPLE USES
Locating a leak in the wall
Place the probe on the surface to be
tested. Take a reading and read the
value from the display window. Repeat
this procedure in various places. If the
readings get higher, then you are get-
ting closer to the leak. If the values stop
increasing, you’ve found the leak.
7
007709 Feuchtigkeitsdetector MD_007709 BA_Feuchtigkeitsmesser 27.10.14 16:20 Seite 7

Operating Instructions MD
C
heck the moisture content of construction
materials
e.g. concrete, tile, screed, plaster, carpets prior to
finishing.
Check the moisture content of wood
e.g. of firewood or wood as a building material
Determining the moisture content of soil
Use the setting for “construction materials”
IMPORTANT NOTICES
Place the probe tips on the surface
carefully, do not apply force.
Handle the device carefully when the protective cap
has been removed. The probes can cause injuries if
used improperly.
When measuring soil, you will get low
readings if the readings are only
taken at the surface and higher
Soil
Soil
readings the deeper you press the
probes into the soil. The measured
value will differ significantly if you
take readings in loose or tightly
packed flower garden soil.
If the probes are set on a metal or a conductive
surface, the maximum value of >>50<< or >>33<< will
appear in the display.
Metal
Keep the probes clean using a damp cloth and put
them back in the protective cap.
8
007709 Feuchtigkeitsdetector MD_007709 BA_Feuchtigkeitsmesser 27.10.14 16:20 Seite 8

MD Operating Instructions
TECHNICAL DATA:
- Power source: 9V DC alkaline block battery (not included in this
package)
- Automatic shut-down: after 3 minutes
- Measurement range: 5% - 50% (wood); 1.5% - 33% (construction
materials)
- Resolution: 0.1%
- Precision: +/– 3%
- Reference values for moisture content:
Moisture Content wood (%) construction materials (%)
5 – 50 % 1,5 – 33 %
Low 5 – 11,9 % 1,5 – 16,9 %
Middle 12 – 15,9 % 17 – 19,9 %
Hight 16 – 50 % 20 – 33 %
Disposal
Please dispose of your used electronic devices in an
environmentally friendly manner!
Electronic devices do not belong in your household waste.
compliant with European Guideline 2012/19/EG concerning
Electrical and Electronic Devices, used electronic devices must be
collected separately and taken to a facility for environmentally sound
recycling. You can find out about your options for disposing of your
used electronic devices from your community or city government.
Improper disposal of batteries can harm the environment!
Batteries do not belong in your household waste. They can
contain poisonous heavy metals and are subject to treatment as
hazardous waste. For this reason, please take your used batteries to
your local collection site.
9