Rotel RT-06: Basic Operating Controls

Rotel

Basic Operating Controls: Rotel RT-06

background image

8

RDV-1092 

8

RT-06 

DAB/AM/FM Stereo Tuner

the antenna to a wall, if desired. Experiment 

with positioning for best reception.

NOTE

To use an outdoor antenna, connect its 

75 ohm coax lead wire to the FM connec-

tor in place of the indoor wire antenna, only 

after a professional contractor has installed 

the antenna system in accordance with lo-

cal  electrical  codes.  In  the  USA,  you  will 

need to use the supplied F-type converter to 

connect the 75 ohm coax cable to the an-

tenna input.

AM Loop Antenna

The RT-06 includes a loop antenna to receive 

AM radio signals. Remove this antenna from 

the box and locate it near the RT-06.

Connect the 300 ohm twin-conductor wire 

from the loop antenna to the pair of screw 

terminals labeled AM LOOP, attaching one 

wire to each terminal. It does not matter which 

wire attaches to which terminal, but make 

sure that the connections are solid and that 

the two wires do not touch.

You may need to rotate or otherwise reorient 

the antenna to find the best position.

NOTE

To use an outdoor antenna, connect its 

300 ohm twin-conductor wire to the G and 

AM terminals in place of the loop antenna, 

only after a professional contractor has in-

stalled  the  antenna  system  in  accordance 

with local electrical codes.

DAB Antenna 

Included is a DAB indoor antenna. If you 

cannot obtain good reception using this sup-

plied antenna, it is recommended to use an 

outdoor DAB antenna. The outdoor antenna 

can be connected with a F-type connector 

(male) then to the “Antenna DAB” connec-

tion on the rear panel.

RCA Outputs 

Line level RCA audio outputs send a fixed-

level stereo signal from the RT-06 to your 

pre-amplifier, system controller or integrated 

amplifier.

Use a standard RCA audio cable to connect 

the LEFT OUTPUT jack to the left channel tuner 

input on your system controller and the RIGHT 

OUTPUT jack to the right channel tuner input 

on your system controller.

DAB Digital Outputs 

One coaxial and one S/PDIF output capable 

of outputting available DAB (Digital Audio 

Broadcast) stations. DAB provides interface 

free reception. DAB is also capable of pro-

viding near CD quality audio as well as cor-

responding broadcast data.

Computer I/O 

The RT-06 can be operated from a computer 

with audio system control software from third-

party developers. This control is accomplished 

by sending operating codes from the computer 

via a hardwired RS-232 serial connection. 

In addition, the RT-06 can be updated using 

special software from Rotel.

The Computer I/O input provides the neces-

sary network connections on the rear panel. It 

accepts standard RJ-45 8-pin modular plugs, 

such as those commonly used in 10-BaseT UTP 

Ethernet cabling. For additional information 

on the connections, cabling, software and 

operating codes for computer control or up-

dating of the RT-06, contact your authorized 

Rotel dealer or Rotel tech support.

EXT REMOTE IN Jack 

The 3.5mm mini-jack receives command 

codes from industry standard infrared receiv-

ers (Xantech, etc) via hard-wired connections. 

This feature could prove useful when the unit 

is installed in a cabinet and the front panel is 

blocked. Consult your authorized Rotel dealer 

for information on these external repeaters 

and the proper wiring of a jack to fit the mini-

jack receptacle.

12V Trigger Connection 

The RT-06 can be activated by a 12volt trig-

ger signal from a Rotel pre-amplifier.

The trigger input accepts any control signal 

(AC or DC) ranging from 3 volts to 30 volts. 

When a cable is connected to the input 

and a trigger signal is present, the tuner is 

activated.

When the trigger signal is interrupted, the 

tuner goes into standby mode. The front panel 

indicator light remains lit, but the display goes 

dark and the unit will not operate.

The RT-06 will also pass a 12V trigger sig-

nal to associated equipment using a trig-

ger. The signal will remain 12V in normal 

operation.

AC Input 

Your RT-06 is configured at the factory for the 

proper AC line voltage in the country where 

you purchased it (120 volts AC at 60Hz in 

the USA and 230 volts AC at 50Hz in Eu-

rope). The AC line configuration is noted on 

a decal on the back of your unit. Make sure 

that your unit is configured properly for your 

AC line voltage.

Plug the supplied cord into the AC INPUT 

receptacle on the back of the unit. Once all 

other rear panel connections are completed, 

plug the power cord into an AC wall outlet 

or switched AC outlet on another system 

component.

Basic Operating Controls

The following explanations will help you get 

familiar with the features and controls. When 

a function is available on both the front panel 

and the remote, a number (see front panel 

illustration) are shown in the instructions. For 

example, to change from the AM to FM band, 

you can either press the front panel button 

or use the button on the remote. When only 

one identifier appears, that control is avail-

able only on the front panel or the remote, 

but not both.

NOTE

Controls used for tuning the DAB/AM/

FM receiver are described in the next sections 

of this manual.

Standby Button   and 

Standby LED   

The STANDBY button is located on the front 

panel of the RT-06 and is not duplicated on 

the remote control.

The STANDBY LED will be lit when the AC 

input line is connected.

ON Button   

Remote only

Pressing the ON button deactivates the stand-

by mode and places the RT-06 into normal 

operation.

Оглавление