e) Maintain power tools. Check for misalignment or
• Secure the workpiece (a workpiece clamped with
binding of moving parts, breakage of parts and any
clamping devices or in a vice is held more securely than
other condition that may affect the power tool’s
by hand)
operation. If damaged, have the power tool repaired
• When sanding metal, sparks are generated; do not use
before use. Many accidents are caused by poorly
dustbag/vacuum cleaner and keep other persons and
maintained power tools.
combustible material from work area
f) Keep cutting tools sharp and clean. Properly
DURING USE
maintained cutting tools with sharp cutting edges are less
• Always keep the cord away from moving parts of the tool;
likely to bind and are easier to control.
direct the cord to the rear, away from the tool
g) Use the power tool, accessories and tool bits etc., in
• Do not touch the moving sanding disc
accordance with these instructions, taking into
• In case of electrical or mechanical malfunction,
account the working conditions and the work to be
immediately switch o the tool and disconnect the plug
performed. Use of the power tool for operations dierent
• If the cord is damaged or cut through while working, do
from those intended could result in a hazardous situation.
not touch the cord, but immediately disconnect the plug
5) SERVICE
AFTER USE
a) Have your power tool serviced by a qualified repair
• When you put away the tool, switch o the motor and
person using only identical replacement parts. This
ensure that all moving parts have come to a complete
will ensure that the safety of the power tool is maintained.
standstill
WHEN CONNECTING NEW 3-PIN PLUG (U.K. ONLY):
SAFETY INSTRUCT IONS FOR SANDERS
• Do not connect the blue (= neutral) or brown (= live) wire
in the cord of this tool to the earth terminal of the plug
GENERAL
• If for any reason the old plug is cut o the cord of this tool,
• This tool should not be used by people under the age of
it must be disposed of safely and not left unattended
16 years
• This tool is not suitable for wet sanding
• Never use the tool when cord is damaged; have it
USE
replaced by a qualied person
• Backing pads
• Do not work materials containing asbestos (asbestos
- never run the tool without backing pad A
is considered carcinogenic)
! replace damaged backing pads immediately
• Alwaysdisconnectplugfrompowersourcebefore
(loosen/fasten 4 pad screws B)
making any adjustment or changing any accessory
! unplug tool before removing/mounting backing
ACCESSORIES
pads
• SKIL can assure awless functioning of the tool only
• Mounting sanding discs
when original accessories are used
- simply press sanding disc C onto backing pad with
• Do not continue to use worn, torn or heavily clogged
perforation in sanding disc corresponding with
sanding discs
perforation in backing pad
BEFORE USE
- if necessary, clean backing pad rst
• Always check that the supply voltage is the same as the
! the dust suction requires the use of perforated
voltage indicated on the nameplate of the tool (tools with
sanding discs
a rating of 230V or 240V can also be connected to a
• Dust suction 4
220V supply)
For optimal dust pick-up performance
• Avoid damage that can be caused by screws, nails and
- mount dustbag E
other elements in your workpiece; remove them before
- empty dustbag regularly
you start working
! do not use dustbag when sanding metal
• Use completely unrolled and safe extension cords with a
• On/o
capacity of 16 Amps (U.K. 13 Amps)
- before switching on the tool, you should place it with
• The noise level when working can exceed 85 dB(A); wear
the entire sanding surface on the workpiece
ear protection
- when switching on, do not apply too much pressure on
• Dust from material such as paint containing lead, some
the tool
wood species, minerals and metal may be harmful
- switch on/o the tool by pulling/releasing trigger F
(contact with or inhalation of the dust may cause allergic
! be aware of the sudden impact when the tool is
reactions and/or respiratory diseases to the operator or
switched on
bystanders); wear a dust mask and work with a dust
! before switching off the tool, you should lift it
extraction device when connectable
from the workpiece
• Certain kinds of dust are classied as carcinogenic (such
• Switch lock 5
as oak and beech dust) especially in conjunction with
- pull trigger F
additives for wood conditioning; wear a dust mask and
- press knob G with your thumb
work with a dust extraction device when
- release the trigger
connectable
- unlock the switch by pulling again trigger F and then
• Follow the dust-related national requirements for the
releasing it
materials you want to work with
• Holding and guiding the tool 6
• Wear protective gloves, safety glasses, close-tting
! while working, always hold the tool at the
clothes and hair protection (for long hair)
grey-coloured grip area(s)
6