Elica OXYGENE: 18 Panel

18 Panel: Elica OXYGENE

background image

18  Panel 

Fig. 2 

Dismantling 

Press the panel upward decisively, the panel will be released 

and roll down freely. ALWAYS ACCOMPANY IT WITH YOUR 

HAND DURING THIS OPERATION. 

Unscrew safety knob S and remove the panel, unhooking it 

from the attachment pins.  

Cleaning:  

The panel should be cleaned with the same frequency as the 

fats filter, use a cloth soaked in neutral detergent liquids.  

Avoid the use of products containing abrasives. DO NOT USE 

ALCOHOL!  

Montage: 

Accompany the panel upward and press until the pins of the 

panel fit correctly into the slot of the hood. 

Attention!  Always check that the panel is fixed well n its 

place.  

Grease filter 

Fig. 3 

This must be cleaned once a month using non aggressive 

detergents, either by hand or in the dishwasher, which must 

be set to a low temperature and a short cycle.  When washed 

in a dishwasher, the grease filter may discolour slightly, but 

this does not affect its filtering capacity. 

Remove the filter holder frame by turning the knobs (g) 90°  

that affix the chimney to the cooker hood. 

Charcoal filter (filter version only) 

Fig. 5 

It absorbs unpleasant odours caused by cooking. 

The charcoal filter can be washed once every two months 

using hot water and a suitable detergent, or in a dishwasher at 

65°C (if the dishwasher is used, select the full cycle function 

and leave dishes out). 

Eliminate excess water without damaging the filter, then put it 

in the oven for 10 minutes at 100° C to dry completely. 

Replace the mattress every 3 years and when the cloth is 

damaged. 

Assembly 

Place the mat around the grease filter and fix it in place using 

the devices provided. 

Position the upper cap and fix it in place using the fixing pin. 

To disassemble, perform the steps in the reverse order. 

Replacing lamps 

Fig. 4 

Disconnect the hood from the electricity. 

Warning!  Prior to touching the light bulbs ensure they are 

cooled down. 

1.  Using a flat head screwdriver or equivalent tool, carefully 

pry loose the light cover.   

2.  Remove the damaged light and replace with a new 12 

Volt, 20 Watt (Maximum) halogen light made for a G-4 

base SUITABLE FOR USE IN OPEN LUMINAIRES.  

Follow package directions and do not touch new light 

with bare hands. 

3.  Reinstall the light  cover. (it will snap shut). 

If the lights do not work, make sure that the lamps are fitted 

properly into their housings before you call for technical 

assistance.