Elica OXYGENE: 16 Installation

16 Installation: Elica OXYGENE

background image

16  Installation 

The minimum distance between the supporting surface for the 

cooking vessels on the hob and the lowest part of the range 

hood must be not less than 50cm from electric cookers and 

65cm from gas or mixed cookers. 

If the instructions for installation for the gas hob specify a 

greater distance, this must be adhered to. 

  Electrical connection 

The mains power supply must correspond to the rating 

indicated on the plate situated inside the hood. If provided with 

a plug connect the hood to a socket in compliance with current 

regulations and positioned in an accessible area. If it not fitted 

with a plug (direct mains connection) or if the plug is not 

located in an accessible area apply a bi-polar switch in 

accordance with standards which assures the complete 

disconnection of the mains under conditions relating to over-

current category III, in accordance with installation 

instructions. 

Warning: Before re-connecting the hood circuit to the mains 

supply and checking the efficient function, always check that 

the mains cable is correctly assembled. 

Mounting 

Before beginning installation:  

• 

Check that the product purchased is of a suitable size for 

the chosen installation area. 

• 

To facilitate installation, remove the fat filters and the 

other parts allowed and described here, dismantle and 

mount it. 

To remove see also the relative paragraphs. 

• 

Remove the active carbon (*) filter/s if supplied (see also 

relative paragraph). This/these is/are to be mounted only 

if you want lo use the hood in the filtering version. 

• 

Check (for transport reasons) that there is no other 

supplied material inside the hood (e.g. packets with 

screws (*), guarantees (*), etc.), eventually removing 

them and keeping them. 

• 

If possible, disconnect and move freestanding or slide-in 

range from cabinet opening to provide easier access to 

rear wall/ceiling. Otherwise put a thick, protective 

covering over countertop, cooktop or range to protect 

from damage and debris. Select a flat surface for 

assembling the unit. Cover that surface with a protective 

covering and place all canopy hood parts and hardware 

in it. 

•  Disconnect the hood during electrical connection, by 

turning the home mains switch off. 

• 

In addition check whether near the installation area of the 

hood (in the area accessible also with the hood mounted) 

an electric socket is available and it is possible to 

connect a fumes discharge device to the outside (only 

suction version).  

•  Carry out all the masonry work necessary (e.g. 

installation of an electric socket and/or a hole for the 

passage of the discharge tube). 

Expansion wall plugs are provided to secure the hood to most 

types of walls/ceilings. However, a qualified technician must 

verify suitability of the materials in accordance with the type of 

wall/ceiling. The wall/ceiling must be strong enough to take 

the weight of the hood. Do not tile, grout or silicone this 

appliance to the wall. Surface mounting only. 

  

Fig. 6 

1.  Adjust extension of the hood support structure, as the 

final height of the hood depends on this. 

Note: In some cases the upper section of the lattice is 

fixed to the lower section with one or more screws, 

eventually check and remove them temporarily to allow 

the adjustment of the support structure. 

2.  Fix the two sections of the structure with a total of 16 

screws (four per corner).  

Note: If envisaged, insert the reinforcement bracket in 

the lattice and put it on top of the motor unit.  

The bracket should be fixed in place again only after the 

perforated frame has been fitted to the ceiling. 

  

Fig. 7 

3.  Apply the drilling template to the ceiling vertically over the 

cooking top (the centre of the template should 

correspond to the centre of the cooking top and the sides 

should be parallel to the sides of the cooking top – the 

side of the template with the word FRONT (or with the 

arrows) corresponds to the control panel side). Connect 

the electricity.  

4.  Drill as shown (6 holes for 6 wall plugs – 4 plugs for 

fixture), screw the outer screws leaving a space of about 

1 cm. between the screw head and the ceiling. 

  

Fig. 8-9 

5.  Fit an exhaust pipe inside the truss and connect it to the 

motor compartment connection ring (exhaust pipe and 

fixing brackets are not supplied). 

For filter versions (5F), fit deflector F to the truss and 

secure it to the bracket supplied using 4 screws, then 

connect the exhaust pipe to the connection ring located 

on the deflector. 

  

Fig. 10 

6.  Hook the frame onto the 4 screws (see step 4). 

CAUTION!  The side of the truss with connection box 

corresponds to the side of the control panel with hood 

assembled. 

7.  Tighten the 4 screws. 

8.  Insert and tighten another 2 screws in the remaining free 

holes for secure fixing. 

Note - only for the suction Version: connect the upper 

end of the discharge tube to the discharge device toward 

the exterior (e.g. hole in the ceiling).   

9.  Fix the reinforcement bracket (see operation 2) to the 

lattice in as intermediate a position as possible.  

  

Remove the grease filters.