The meaning of display indications

Flashing display

11

Start-up after power failure

Risk of scalding!

If the temperature display flashes, the temperature of the

water leaving the tap is higher than the set temperature.

Open the warm water tap fully and allow a minimum wa-

ter flow of 6 litres/minute.

Cleaning

Only wipe off the appliance using a moist cloth. Do not

use acidic or abrasive cleaning materials.

The supply temperature from the domestic system is too

high, e. g. water from a solar energy unit.

Do not use a steam cleaner.

The thermostatic premixer in the domestic supply must be

set accordingly to lower temperatures.

Customer Service

Error signals

We ask you to always provide the E-No. and the FD-No. of

your appliance when calling in a customer service engineer.

Sometimes e. g. E02 (or E03 to E14) appears in the display

You will find the numbers on the inner side of the fold up

due to a very minor problem. Please try to eliminate the fault

operating panel on the continuous-flow heater.

according to guidelines given in the chapter "A fault, what to

do?". You will save yourself the cost of an unnecessary visit

by customer service personnel.

Using the appliance after switching

off the water supply

Switch off the appliance (unscrew the fuse in the house

electrical installation).

Open the warm water tap and keep it open until the air

has been completely forced out of the water pipe.

Switch the fuse back on again.