Siemens DE1821515: Special accessories Operating instructions Operating the continuous-flow heater Safety information Your new appliance
Special accessories Operating instructions Operating the continuous-flow heater Safety information Your new appliance: Siemens DE1821515
Table of contents
- Installation instructions Installation
- Technical data
- Special accessories Operating instructions Operating the continuous-flow heater Safety information Your new appliance
- Start-up after power failure Cleaning Customer Service Using the appliance after switching off the water supply
- A fault, what to do? Fault Cause Solution Who
- Fault Cause Solution Who

en
10
236
99
Special accessories
20
Pipe kit ■ BZ 45U20: for use of the continuous-flow heater
as an under sink appliance
■ BZ 45L20:
Priority switch (load shedding relay)
for operation with a priority circuit
Mounting kit ■ BZ 45K23: for surface mount installation
472
332
388
Thermostatic premixer ■ BZ 45T20: for installation in the
domestic plumbing when using preheated water
G
1
2
A
42
100
115
Operating instructions
Operating the continuous-flow
heater
Please read the operating instructions carefully before
you use the appliance!
The default temperature for the water temperature after
setting the first start-up or a power failure is 40 °C.
Safety information
Selecting shower temperature
■
This appliance is intended for domestic use or for house-
Select the required temperature with the rotary knob used to
hold-based non-commercial applications. Household-
vary the desired temperature from 20 °C to 60 °C in steps of
based applications include, e.g. usage in employees
0.5 °C.
catering facilities for shops, offices, agricultural and
other commercial operations, as well as usage by guests
Info: The temperature shown in the display is the water tem-
of guest houses, small hotels and similar residential
perature inside the appliance. The temperature of the water
establishments.
leaving the tap can vary from this due to heat losses in the
pipework.
Risk of electric shock!
Switch off the mains voltage supply immediately if
a fault occurs.
■
We do not accept liability for damage resulting from
failure to heed these instructions.
■
The continuous-flow heater may only be connected
and put into operation by a qualified professional.
■
Repairs may only be undertaken by a suitably qualified
specialist to avoid potential sources of danger.
■
The continuous-flow heater may only be installed in a
frost-free room.
■
Persons (including children) with diminished bodily, sen-
Conserving energy and water
sory or mental perception, or those who lack knowledge or
experience should not operate the appliance, unless they
Mixing in of cold water in the fitting requires unnecessary
are monitored or have received instruction concerning use
water and energy. You should therefore set the desired tem-
of the appliance by persons responsible for their safety.
perature directly on the continuous-flow heater and then
■
Keep children away from the appliance. Please moni-
open the water tap.
tor children to ensure that they do not play with the
appliance.
■
The mixer and the warm water pipe may be hot.
Please switch off all fuses immediately if a malfunction ■
occurs. Immediately shut off the cold water supply to the
appliance should it leak. The malfunction can only be re-
paired by a specialist or an authorised service agent.
Your new appliance
The electronic continuous-flow heater “electronic comfort
plus” is intended exclusively for heating water which flows
through the appliance.
Pre-warmed water
The continuous-flow heater switches on and heats the water
The continuous-flow heater can be operated with pre-
when the warm water tap is opened. It switches off as soon as
warmed water (for example from a solar energy unit).
the tap is closed.