A fault, what to do?
If your appliance does not operate as required, it is often due to a very minor problem. Please check whether you can remedy
the fault yourself by using the following guidelines. You will save yourself the costs of an unnecessary visit by customer service
personnel.
Fault Cause Solution Who
Water flow-rate is too low. The filter in either the water tap or
Remove the filter and either
Customer
the showerhead is clogged.
clean it or descale it.
The filter in the corner regulating
Get a servicing expert to clean the
Servicing
valve is clogged.
filter.
expert
The desired water temperature is
The continuous-flow heater is
Set the temperature on the continu-
Customer
set, but it is not reached.
connected to a thermostatically-
ous-flow heater to “60 °C”.
controlled water faucet.
The display is blank The fuse in the house electrical in-
Check the fuse in the house electri-
Customer
stallation has triggered/blown.
cal installation.
The appliance's automatic circuit
Get the appliance's automatic
Servicing
breaker has been tripped.
circuit breaker checked by an
expert
electrician.
The water is not warm. The fuse in the house electrical in-
Check the fuse in the house electri-
Customer
stallation has tripped/blown.
cal installation.
From time to time, cold water
The air sensor in the appliance de-
After a few seconds, the continu-
Continuous-
flows out.
tects air in the water and momen-
ous-flow heater automatically goes
flow heater
tarily switches the heating element
back into operation.
automati-
off.
cally resolves
problem
The set temperature, for instance
The temperature of the water
The thermostatic premixer in the
Customer
41.0 °C flashes. The temperature
supplying the continuous-flow
domestic supply must be set ac-
of the water leaving the tap is
heater is higher than the set tem-
cordingly to lower temperatures.
higher than the set temperature.
perature (e. g. due to pre-warmed
water supplied from a solar water
heater).
Winter operation:The desired wa-
The supply temperature has
Reduce the water flow on the taps
Customer
ter temperature leaving the tap is
reduced.
until the desired water temperature
no longer reached.
is reached.
E02 No thermostatic premixer available
Install a thermostatic premixer in
Customer
The supply temperature to the
the domestic supply.
continuous-flow heater is higher
than 55 °C (e. g. due to pre-warmed
water supplied from a solar water
heater).
The supply temperature to the
The thermostatic premixer in the
continuous-flow heater is higher
domestic supply must be set ac-
than 55 °C (e. g. due to pre-warmed
cordingly to lower temperatures.
water supplied from a solar water
heater).
E03–E04 Temperature sensor defective Please contact customer service. Customer
Service
E05–E07 Electronic malfunction Please contact customer service. Customer
Service
E08 Frost damage
The appliance is defective! Switch
Customer/
The water supply sensor measures
off the water supply immediately
Servicing
a temperature on ≤ 0 °C.
and disconnect the appliance from
expert
the electrical supply (also refer to
the safety instructions)
Please contact customer service.