Rotel RA-1062: Specifications

Specifications: Rotel RA-1062

background image

9

Specifications

Continuous Power Output

60 watts/channel (20-20 kHz, < 0.03%, 8 ohms)

Total Harmonic Distortion (20Hz-20kHz)

< 0.03% at rated power, 1/2 power, or 1 watt

Intermodulation Distortion (60 Hz : 7 kHz, 4:1)

  < 0.03% at rated power, 1/2 power or 1 watt

Frequency Response 

Phono Input

20Hz-15kHz, ±0.2dB 

Line Level Inputs

10Hz-100kHz, +1, –3dB

Damping Factor (20-20,000 Hz, 8 ohms)

150

Line Input Sensitivity / Impedance

160 mV / 24 kOhms

Line Input Overload

5 V

Phono (MM) Sensitivity / Impedance 

2.4mV /47 kohms

Input (Phono) Overload

  

170 mV

Preamplifier Output / Impedance

1V / 470 ohms

Signal to Noise Ratio (IHF “A” weighted)

>95 dB

Power Requirements 

USA:

115 Volts, 60 Hz 

EC:

  

230 Volts, 50 Hz

Power Consumption

300 Watts

Dimensions (W x H x D)

430 x 92 x 355 mm 

17 x 5

5

/

8

 x 14 inches

Front Panel Height

80mm / 3

3

/

16

 inches

Weight (net)

7.8 kg, 17.2 lbs.

All specifications are accurate at the time of printing.

Rotel reserves the right to make improvements without notice.

Rotel and the Rotel HiFi logo are registered trademarks of The Rotel Co, Ltd., Tokyo, Japan.

Troubleshooting

Most difficulties in audio systems are the result 

of incorrect connections, or improper control 

settings. If you encounter problems, isolate the 

area of the difficulty, check the control settings, 

determine the cause of the fault and make the 

necessary changes. If you are unable to get 

sound from the RA-1062 refer to the sugges-

tions for the following conditions:

Power Indicator Is Not Lit

The power indicator should be lit whenever the 

RA-1062 is plugged into the wall power outlet 

and the POWER switch is pushed in. If it does 

not light, test the power outlet with another 

electrical device, such as a lamp. Be sure the 

power outlet being used is not controlled by 

a switch that has been turned off.

Fuse Replacement

If another electrical device works when plugged 

into the power outlet, but the power indicator 

still will not light when the RA-1062 is plugged 

into the wall outlet, it indicates that the internal 

power fuse may have blown. If you believe this 

has happened, contact your authorized Rotel 

dealer to get the fuse replaced.

No Sound

Check the signal source to see if it is func-

tioning properly. Make sure the cables from 

the signal source to the RA-1062 inputs are 

connected properly. Be sure the LISTENING 

selector is set to the proper input. Be sure the 

SPEAKERS selector is set to the proper posi-

tion. Check the wiring between the RA-1062 

and the speakers.

English