Siemens DE27401: Customer Service A fault, what to do? Fault

Customer Service A fault, what to do? Fault: Siemens DE27401

background image

11

en

Cleaning

Simply wipe the appliance with a damp cloth.

Do not use intensive or abrasive cleaning agents.

Customer Service

We ask you to always provide the E-No. and the FD-No. of 

your appliance when calling in a customer service engineer. 

You will find the numbers on the inner side of the fold up 

operating panel on the continuous-flow heater.

A fault, what to do?

If your appliance does not operate as required, it is often due to a very minor problem. Please check whether you can remedy 

the fault yourself by using the following guidelines. You will save yourself the costs of an unnecessary visit by customer service 

personnel.

Fault

Cause

Solution

Who

Water flow-rate is too low.

The filter in either the water tap or 

the showerhead is clogged 

Remove the filter and either

clean it or descale it.

Customer

The filter in the corner regulating 

valve is clogged.

Get a servicing expert to clean the 

filter.

Servicing 

expert

The filter upstream from the check 

valve in the cold water supply inlet 

is clogged.

Remove the filter and either

clean it or descale it.

Servicing 

expert

The desired water temperature is 

not reached.

The continuous-flow heater is 

connected to a thermostatically-

controlled water tap.

Set the temperature on the continu-

ous-flow heater to “max”.

Customer

The power limit has been reached. 

Water flow-rate is too high and/or 

the cold water supply temperature 

is too low.

Reduce the flow-rate at the water 

tap supply.

Customer

By a qualified professional:

use the angle valve to regulate the 

flow-rate. 

Check the flow-rate limiter or re-

place it with a smaller one.

Servicing 

expert

The water is not sufficiently warm.

The fuse in the house electrical in-

stallation has tripped/blown.

Check the fuse in the house electri-

cal installation.

Customer

The appliance‘s automatic circuit 

breaker has been tripped.

Get the appliance‘s automatic cir-

cuit breaker checked by an electri-

cian. Check the permissible supply 

temperature.

Servicing 

expert

The power limit has been reached. 

Water flow-rate is too high and/or 

the cold water supply temperature 

is too low.

By a qualified professional:

use the angle valve to regulate the 

flow-rate. 

Check the flow-rate limiter or re-

place it with a smaller one.

Servicing 

expert

From time to time, cold water 

flows out.

The air sensor in the appliance de-

tects air in the water and momen-

tarily switches the heating element 

off.

After a few seconds, the continu-

ous-flow heater automatically goes 

back into operation.

Continu-

ous-flow 

heater au-

tomatically 

resolves 

problem