14

RKB-2100   Power Amplifier

Specifications

Continuous Power Output into 8 ohms 

(20-20k Hz, < 0.03% THD)

100 watts/ch into 8 ohms, all channels driven 

Continuous Power Output into 4 ohms 

(DIN 1 kHz,1.0% THD)

170 watts/ch into 4 ohms, all channels driven

Total Harmonic Distortion  

(20Hz-20kHz, 8 ohms)

Continuous rated power: < 0.03% 

One-half rated power: < 0.03% 

1 watt power: < 0.03%

Intermodulation Distortion  

(60 Hz : 7 kHz, 4:1)

< 0.03%

Damping Factor  

(20-20,000 Hz, 8 ohms)

>200

Input Impedance

20 k Ohms

Input Sensitivity

1.0 volt

Amplifier Gain:

29 dB

Input Overload Level

5.0 volt

Peak Current

> 60 A

Frequency Response (±1 dB)

4Hz-100kHz

S/N Ratio (IHF A)

120 dB

Crosstalk/Separation

> 70 dB

Speaker Impedance  

4 ohms minimum

Auto Turn On Level (with all inputs) 

3 mV input signal

Power Requirements 

USA: 120 Volts, 60 Hz 

Europe: 230 Volts, 50 Hz

Power Consumption

450 Watts 

Idle: 40 Watts 

Standby: 2.3 Watts

Dimensions (W x H x D) 

(not including rack adaptors) 

430 x 144 x 328 mm 

16.9 x 5.7 x 12.9 in

Weight (net)

11.2 kg, 25 lb.

Panel Height 

3U, 132.6 mm/5.2 in

When sizing openings in custom cabinets, mea-

sure the unit to be installed and/or allow at least 

1 mm clearance on all sides for unit to unit toler-

ances.

All specifications are accurate at the time of print-

ing. Rotel reserves the right to make improve-

ments without notice.

Rotel and the Rotel HiFi logo are registered trade-

marks of The Rotel Co, Ltd., Tokyo, Japan.

Troubleshooting

Most difficulties in audio systems are the result 

of poor or wrong connections, or improper 

control settings. If you encounter problems, 

isolate the area of the difficulty, check the 

control settings, determine the cause of the 

fault and make the necessary changes. If you 

are unable to get sound from the RKB-2100, 

refer to the suggestions for the following 

conditions:

Front Panel Power Indicator Is  Not Lit

No main power to the RKB-2100. Check AC 

power connections at the amplifier and the AC 

outlet. Check the front panel power switch. 

Make sure that it is set to the ON position. 

If using signal sensing auto power-on, make 

sure that a signal is present at the inputs. If 

using 12V trigger power-on, make sure that 

a trigger signal is present at rear panel +12V 

TRIGGER connector.

No Sound

If the amp is getting AC power, but is pro-

ducing no sound, check the PROTECTION 

INDICATOR on the front panel. If lit, see be-

low. If not, check all of your connections and 

control settings on associated components. 

Make sure that your input connections and 

speaker connections match your selected 

stereo/mono configuration.

Protection Indicator Is Lit

The front panel PROTECTION INDICATOR 

lights when the RKB-2100 protection circuits 

have shut off the amplifier. Typically, this oc-

curs only when the ventilation openings are 

blocked, when there is faulty speaker wiring, 

or after a period of extreme use. Turn off the 

system and wait for the amp to cool. Then 

push the front panel power switch in and out 

to reset the protection devices. If the problem 

is not corrected or reoccurs, there is a problem 