1.1 Intended use

GHN,GHNDmodelsofIMP-pumpsareintendedfortransportingthemediainheating,

cooling, conditioning and ventilating systems.

GB

1. 2 Product information

1. 2.1 Rating plate

1.2.2 Technical data

- protection type IP 44

- insulation class 200

- the motor is protected with series-produced klickson

- soundpressurelevel<70dB(A)

- mediatemperature-10°Cto+120°C.

- ambienttemperaturemax.40°C

- max.allowablepressureinthesystemcanbe1MPa(10bar).

1.2.3 Media types:

- heating water according to VDI 2035

- mixtureofwaterandglycol,withupto50%ofglycolcontent.Incaseofamixturecontaining

glycoltheinformationonpumpingistobecorrectedwithregardtohigherviscosity.Use

onlyglycol,protectedagainstcorrosionandfollowthemanufacturer‘sinstructions.

- TousetheothermediaIMPPUMPS‘sapprovalisrequired.

- Whileorderingsparepartspleaseprovideallinformationindicatedontheratingplates.

2. Safety

Important:Readtheoperationalandsafetyinstructionsbeforeinstallationandstartup!

2.1 Identication of hints in the operating instructions

- General danger

- Danger - High voltage