• Toavoidoverloadingthemechanicalcomponents,therecommended

permittedrelative dierential pressuresare:

EN

DN15–50max.24 bar

DN65–100max.20 bar

DN150–200max.15 bar

Recommendedinstallationfor

Pressure-reducing

pressure-reducingvalves

valve

Dirttrap(0.1mm)

Mediumtemperature< 100 °C

Medium

Installationdistancefromvalve10 x DN

(atleast1m)

Medium

Recommendedinstallationfor

pressure-reducingvalves

Rundowntank

Mediumtemperature> 100 °C

Recommendedinstallationfor

Reliefvalve

relief valves

Dirttrap(0.1mm)

Mediumtemperature< 100 °C

Medium

Installationdistancefromvalve10 x DN

(atleast1m)

Medium

Recommendedinstallationfor

relief valves

Rundowntank

Mediumtemperature

> 100 °C

If using a rundown tank, make sure that it is gravity driven and located

at a higher level than the actuator!

EN

2. Commissioning Themediumandthevalvecanposethefollowinghazards:

• Criticaloperatingconditionscancauseimpermissiblelevels

ofnoiseandvibration.

Hearing loss, vascular and nerve problems, damage to joints and bones!

• Incorrectmaintenancecanresultin the operating medium

escaping.

Danger of burns, freezing!

• Thetemperatureoftheoperatingmediumistransferredtothe

surfaceofthevalve.

Danger of burns, freezing!

Asthesehazardscanallbecontrolledbytheplantoperator,

theoperatorisobligedtocomplywithnationalandinternational

environmentalregulations,installsuitableprotectivemeasures

toensureworkplacerequirementsaresatised,andtoinstruct

hisemployeesaccordingly.

Due to the risk of injury, it is prohibited to work between

the yoke/columns while the valve is in operation.

Oncethesehazardshavebeenavertedbyadoptingappropriate

protectivemeasures,thevalvecanbeinstalledandconnected

inthepiping.Thefollowingpointsshouldbenoted:

• Flangeconnection:

Connectionmaterial(gaskets,bolts,nuts)arenotpartofthe

scopeofsupply.

Locate gaskets in the centre of anges, failure to do so can result in leaks and

increased noise levels.

If a completely installed piping is to be ushed or blown through for cleaning,

replace the control valve with a matching piece.