Panasonic AW-IF400G: Connections

Connections: Panasonic AW-IF400G

Connections

• Before proceeding with the connections, turn off the power.

• For further details on connecting the devices, refer to the operating instructions accompanying

the devices concerned.

• For further details on operating the devices, refer to the operating instructions accompanying

the devices concerned.

• Use a separate cable compensator if the video signal cable is longer than 500 meters.

- 9 (E) -

ENGLISH

Connections

When controlling AW-PH400

Zoom lens

from AW-RP605A (AW-RP605/AW-RP555/AW-RP655)

Main unit

10BASE-T (UTP category 5)

straight cable

(max. 1000 m)

Camera cable

supplied with

AW-PH400

CONTROL OUT

TO PAN/TILT HEAD

AC adapter

AW-PS505A

(max. 500 m)

Convertible

camera

IP/RP

AC power cable

Control panel

supplied with

AW-PH400

Protocol converter

Indoor pan/tilt head

AW-IF400G

AW-PH400

• Switch settings

Multi-function controller

SET UP

SW1 SW2

AW-RP605A

AC adapter

1 2 3 4

AW-PS505A

ON

OFF

OFF OFF ON OFF

OFF

(300 deg)

(190 deg)

- 10 (E) -

Connections

When using the extended distance transmission function

Zoom lens

of AW-RP400 and AW-PH400 (AW-PH360)

10BASE-T (UTP category 5)

CONTROL OUT

straight cable

TO PAN/TILT

HEAD

(max. 500 m)

AC adapter

Camera cable

AW-PS505A

supplied with

AW-PH400

(max. 500 m)

Convertible

IP/RP

camera

AC power cable

supplied with

AW-PH400

Protocol converter

Indoor pan/tilt head

AW-IF400G

AW-PH400

Pan/tilt control panel

Remote

AW-RP400

operation

panel

• Switch settings

AW-CB400

AC adapter

SET UP

SW1 SW2

AW-PS505A

1 2 3 4

ON ON OFF OFF OFF OFF

- 11 (E) -

ENGLISH

Connections

When controlling AW-PH350 (AW-PH360/AW-PH650)

Zoom lens

from AW-RP400

Camera cable

AW-CA50T29

AW-CA50C29

10BASE-T (UTP category 5)

CONTROL OUT

straight cable

TO PAN/TILT

Convertible

HEAD

(max. 500 m)

AC adapter

camera

AW-PS505A

CONTROL IN

(max. 1000 m)

IP/RP

Indoor pan/tilt head

AC adapter

AW-PH350

AW-PS300A

Protocol converter

AW-IF400G

Pan/tilt control panel

Remote

AW-RP400

operation

panel

• Switch settings

AW-CB400

AC adapter

SET UP

SW1 SW2

AW-PS505A

1 2 3 4

OFF ON OFF ON OFF OFF

- 12 (E) -