AC Power Input 

8

The RMB-1077 is supplied with the proper AC 

power cord. Use only this cord or an exact 

equivalent. Do not use an extension cord. A 

heavy duty multi-tap power outlet strip may 

be used, but only if it is rated to handle the 

current demand of the RMB-1077.

Be sure the Power Switch on the front panel of 

the RMB-1077 is turned off. Then, plug one 

end of the cord into the AC power connector 

8

 on the back panel of the amplifier. Plug the 

other end into an appropriate AC outlet.

Your RMB-1077 is configured at the factory 

for the proper AC line voltage in the country 

where you purchased it (USA: 120 volts/60 

Hz, Europe: 230 volts/50 Hz). The AC line 

configuration is noted on a label on the back 

panel.

NOTE:

 Should you move your RMB-1077 

to another country, it is possible to configure 

your amplifier for use on a different line 

voltage. Do not attempt to perform this con-

version yourself. Opening the enclosure of 

the RMB-1077 exposes you to dangerous 

voltages. Consult a qualified technician or 

the Rotel factory service department for in-

formation.

If you are going to be away from home for 

an extended period of time, it is a sensible 

precaution to unplug your amplifier. 

Power Switch and  

Indicator 

12

The Power Switch is located on the front panel. 

To turn the amplifier on (or to activate either of 

the optional automatic power-on modes), push 

the switch in. The LED indicator above the switch 

will light, indicating that the amplifier is turned 

on. To turn the amplifier off, push the button 

again and return it to the out position.

Turn On/Off Mode Selector 

5

The RMB-1077 can be turned on and off  au-

tomatically by using its “12V Trigger” system. 

The Turn On/Off Mode Selector switch is used 

to select which method is used. 

•  With the switch in the OFF position, the 

amplifier is turned on or off manually using 

the front panel power switch. 

•  With the switch in the 12V TRIG. position, 

the amplifier is turned on automatically 

when a 12 volt trigger signal is applied to 

the 3.5mm Jack labeled IN. The front panel 

POWER SWITCH overrides this function. It 

must be ON for the +12V trigger to work. 

Turning the switch OFF cuts power to the 

amplifier, regardless of whether or not a 

trigger signal is present.

+12V Trigger Input  

and Output 

6

The jack labeled IN is for connecting the 3.5mm 

Plug/Cable carrying a +12 volt trigger signal 

to turn the amplifier on and off. To use this 

feature the adjacent switch 

5

must be set in 

the 12V TRIG position (see previous section). 

This input accepts any control signal (AC or 

DC) ranging from 3 volts to 30 volts.

The jack labeled OUT is for connecting another 

3.5mm plug/cable to provide a 12V trigger 

signal to other components. The 12V output 

signal is available whenever a +12 volt trigger 

signal is applied to the IN connector.

Protection Indicators 

3

Thermal and protection circuits protect the 

amplifier against potential damage in the event 

of extreme or faulty operating conditions. Un-

like many designs, the RMB-1077’s protection 

circuit is independent of the audio signal and 

has no impact on sonic performance. Instead, 

the protection circuit monitors the temperature 

of the output devices and shuts down the ampli-

fier if safe limits are exceeded.

In addition, the RMB-1077 includes overcur-

rent protection which operates only when load 

impedances drop too low. This protection is 

independent for each of the seven channels.

Should a faulty condition arise, the amplifier 

will stop playing and the PROTECTION LED 

on the front panel will light. 

If this happens, turn the amplifier off, let it 

cool down for several minutes, and attempt to 

identify and correct the problem. When you 

turn the amplifier back on, the protection circuit 

will automatically reset and the PROTECTION 

LED should go out.

In most cases, the protection circuitry activates 

because of a fault condition such as shorted 

speaker wires, or inadequate ventilation lead-

ing to an overheating condition. In very rare 

cases, highly reactive or extremely low imped-

ance speaker loads could cause the protection 

circuit to engage.

RMB-1077 