Rotel RKB-250: Signal Connections

Signal Connections: Rotel RKB-250

background image

12

RKB-250  Power Amplifier

•  With the switch in the SIGNAL SENSE po-

sition, the amplifier turns on automatically 

when a signal is detected at the inputs. 

The amplifier will go into standby mode 

several minutes after no signal is no lon-

ger present. The front panel power switch 

overrides this function. It must be ON for 

the signal sensing to work. Turning the 

switch OFF cuts power to the amplifier, 

regardless of whether or not a signal is 

present.

•  With the switch in the 12V TRIG  position, 

the amplifier is turned on automatically 

when a 12 volt trigger signal is present 

at the 12V TRIG input to the left of the 

switch. The amplifier goes into standby 

mode if the +12 volt signal is not present. 

The front panel POWER SWITCH over-

rides this function. It must be ON for the 

+12V trigger to work. Turning the switch 

OFF cuts power to the amplifier, regard-

less of whether or not a trigger signal is 

present.

12V Trigger Input   

An input jack for connecting the wires car-

rying a +12 volt trigger signal from a Rotel 

preamp or surround sound processor to turn 

the amplifier on and off. To use this feature 

the adjacent slide switch must be placed to 

the left position (see previous section).

The TRIGGER INPUT accepts any control 

signal (AC or DC) ranging from 3 volts to 

30 volts. Using a cable with mono 3.5 mm 

mini-plugs on both ends. The +12 V DC sig-

nal appears at the “tip” connector.

12V Trigger Output   

The 12V TRIG jack labeled OUT is used to 

pass the remote turn-on signal to a second 

Rotel amplifier. Any 12V Trigger signal at 

the INPUT jack will be passed through to 

the OUT jack.

Circuit Breaker   

A 10 amp circuit breaker on the rear panel 

protects the amplifier’s electrical circuity. 

Generally, the circuit breaker will only open 

under a fault condition which results in exces-

sive current draw. To reset the circuit breaker, 

press the button. Should it repeatedly open, 

contact your authorized Rotel dealer for trou-

bleshooting assistance.

Protection Indicators 

A thermal protection circuit protects the am-

plifier against potential damage in the event 

of extreme or faulty operating conditions. Un-

like many designs, the RKB-250’s protection 

circuit is independent of the audio signal and 

has no impact on sonic performance. Instead, 

the protection circuit monitors the tempera-

ture of the output devices and shuts down the 

amplifier if temperatures exceed safe limits.

In addition, the RKB-250 includes overcurrent 

protection which operates only when load 

impedance drops too low. 

Should a faulty condition arise, the ampli-

fier will stop playing and one or both of the 

PROTECTION LEDS on the front panel will 

light indicating a fault with the left and/or 

right channels. 

If this happens, turn the amplifier off, let it 

cool down for several minutes, and attempt 

to identify and correct the problem. When 

you turn the amplifier back on, the protec-

tion circuit will automatically reset and the 

PROTECTION LEDS should go out.

In most cases, the protection circuitry acti-

vates because of a fault condition such as 

shorted speaker wires, or inadequate ventila-

tion leading to an overheating condition. In 

very rare cases, highly reactive or extremely 

low impedance speaker loads could cause 

the protection circuit to engage.

Signal Connections

The RKB-250 provides standard conventional 

input connections — unbalanced RCA type 

connections as found on nearly all audio 

equipment. In addition, there is a pair of SIG-

NAL OUTPUT LINK connections for passing 

the unchanged input signal on to another 

audio component.

RCA Inputs 

See Figure 2

These RCA inputs accept audio signals from 

preamplifiers or surround sound processors. 

Use high quality audio interconnect cables 

for best performance.

Connect the left channel output of your pre-

amp to the LEFT INPUT on the RKB-250. Con-

nect the right channel of your preamp to the 

RIGHT INPUT. 

AC Power and Control 

AC Power Input 

Your RKB-250 is configured at the factory 

for the proper AC line voltage in the country 

where you purchased it (USA: 120 volts/60 

Hz, Europe: 230 volts/50 Hz). The AC line 

configuration is noted on a label on the 

back panel.

The RKB-250 is supplied with the proper AC 

power cord. Use only this cord or an exact 

equivalent. Do not modify the supplied cord. 

Do not use an extension cord. 

Be sure the power switch on the front panel 

of the RKB-250 is turned off. Then, plug one 

end of the cord into the AC power connector 

on the back panel of the amplifier. Plug the 

other end into an appropriate AC outlet.

If you are going to be away from home for 

an extended period of time, it is a sensible 

precaution to unplug your amplifier.

Power Switch     Indicator LED 

The power switch is located on the left side 

of the front panel. To turn the amplifier on 

(or to activate either of the optional auto-

matic power-on modes), push the switch in. 

The LED indicator above the switch will light, 

indicating that the amplifier is turned on. To 

turn the amplifier off, push the button again 

and return it to the out position. 

Auto Turn On/Off Mode Selec- tor   

The RKB-250

provides three different op-

tions for manual or automatic power on/off 

operation. These modes are selectable us-

ing a three-position slide switch on the back 

panel as follows:

•  With the switch in the OFF position, the 

amplifier is turned on or off manually us-

ing the front panel power switch. Also use 

this mode if you are using a switched AC 

outlet to control power to the amplifier.