Read and keep this manual carefully.

Bitte lesen Sie diese Anleitung und

NEDERLAND

bewahren Sie sie auf.

Veuillez lire et enregistrer ces instructions.

Lees en bewaar deze instructies.

Ионный генератор Plasmacluster

Прочтите данное руководство и

РУКОВОДСТВО ПО

сохраните его.

ЭКСПЛУАТАЦИИ

РУССКИЙ

Printed in China

SHARP CORPORATION

TINS-A325KKRZ 09A-

2

OSAKA, JAPAN

IG-A10EU.Eng.indd1IG-A10EU.Eng.indd1 2009/07/2115:38:292009/07/2115:38:29

IG-A10EU.Eng.indd2IG-A10EU.Eng.indd2 2009/07/2115:38:292009/07/2115:38:29

ENGLISH

CONTENTS

...............

IMPORTANT SAFETY INSTRUCTIONS

E-2

...............................................................

• WARNING

E-2

......................

CAUTIONS CONCERNING OPERATION

E-2

......................................

• INSTALLATION GUIDELINES

E-2

........................................................

PARTS NAME

E-3

.................................................................................

• FRONT

E-3

...................................................................................

• BACK

E-3

...........................................

E-4

ENGLISH

INSTALLATION POSITION

......................................................................

OPERATION

E-4

.............................

CLEANING AND MAINTENANCE

E-5

...........................................................................

• MAIN UNIT

E-5

.................................................................................

• FILTER

E-5

....

PLASMACLUSTER ION GENERATING UNIT REPLACEMENT

E-6

....

HOW TO REPLACE THE PLASMACLUSTER ION GENERATING UNIT

E-7

............................................................

SPECIFICATIONS

E-8

....................................................

TROUBLESHOOTING

E-8

While IG-A10EU can inactivate and eliminate suspended viruses

and other contaminants, it cannot create a completely sterile

environment. SHARP does not guarantee its ability to prevent

microbial infection.

To enable stable emission of high-density Plasmacluster ions,

the Plasmacluster Ion Generating Unit mounted in IG-A10EU will

need to be replaced periodically*

.

* Replacement is required approximately every 2 years (17,500 hours) when operated

24 hours a day. IG-A10EU will stop operating after about 26 months (19,000 hours) if

the Plasmacluster Ion Generating Unit is not replaced.

Thank you for purchasing this SHARP Plasmacluster Ion Generator. Please

read this manual carefully before using Plasmacluster Ion Generator.

After reading, keep the manual in a convenient location for future reference.

E-1

IG-A10EU.Eng.indd3IG-A10EU.Eng.indd3 2009/01/2711:12:322009/01/2711:12:32

IMPORTANT SAFETY INSTRUCTIONS

When using electrical appliances, basic safety precautions should be followed, including the following:

WARNING - To reduce the risk of electrical shock, re, or injury :

• Read all instructions before using the unit.

• Use only a 220-240 volt outlet.

• DO NOT use the unit if the power cord or plug is damaged, or the connection to the wall outlet

is loosened.

• Periodically remove dust from the plug.

• DO NOT insert ngers or foreign objects into the air intake or air outlet.

Always hold the plug and never pull on the cord when removing the power plug.

Electrical shock and/or re from a short circuit may result.

• DO NOT remove the plug when your hands are wet.

• DO NOT use the unit near gas appliances or replaces.

• If the power cord is damaged, it must be replaced by the manufacturer, its service agent, a

Sharp authorized Service Center or quali ed person in order to avoid a hazard.

• Be cautious when cleaning the unit.

Strong corrosive cleansers may damage the exterior.

• DO NOT use it in the areas where the unit may get wet.

• DO NOT use spray products near the unit.

DO NOT use in the rooms, containing oil component, incense, cigarettes’ sparks, and chemical fumes.

• DO NOT operate when using aerosol insecticides or in rooms where there is oily residue, in-

cense, sparks from lit cigarettes, chemical fumes in the air, or in locations where the unit may

get wet, such as a bathroom.

• Only a Sharp Authorized Service Center should service this Plasmacluster Ion Generator.

Contact the nearest Service Center for any problems, adjustments, or repairs.

• This appliance is not intended for use by persons (including children) with reduced physical,

sensory or mental capabilities, or lack of experience and knowledge, unless they have been

given supervision or instruction concerning use of the appliance by a person responsible for

their safety.

• Children should be supervised to ensure that they do not play with the appliance.

CAUTIONS CONCERNING OPERATION:

• DO NOT block the air intake and/or air outlet.

• DO NOT use the unit near or on hot objects, such as stoves or heaters or where it may come

into contact with steam.

Always operate the main unit in an upright position.

• Clean the exterior with a soft cloth only, otherwise the main unit surface may be damaged or

cracked.

• Keep the main unit away from water.

INSTALLATION GUIDELINES:

• Place at least 2m away from equipment utilizing electric waves such as televisions or radios to

avoid electrical interference when using the unit.

Avoid using in locations where the unit is exposed to condensation or drastic temperature

changes. Appropriate room temperature is between 0-35ºC.

Avoid locations where grease or oily smoke is generated, otherwise the main unit surface may

crack as a result.

NOTE - Radio or TV Interference:

If this Plasmacluster Ion Generator may cause interference to radio or television reception,

try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the distance between the unit and radio/TV receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

E-2

IG-A10EU.Eng.indd4IG-A10EU.Eng.indd4 2009/01/2711:12:322009/01/2711:12:32

PARTS NAME

FRONT

Louvers

(See E-4)

DISPLAY

Unit Replacing

Top Cover Cap

Light

(red)

(See E-6)

Screws

High

(blue)

Air outlet

ENGLISH

Top Cover

Operation

Low

(blue)

Plasmacluster Ion

Button

Fan Speed

Generating Unit

Indicator

(See E-6,7)

Filter (Air Intake)

Filter (Air Intake)

(See E-5)

BACK

Use a pointed object, e.g a pen tip, to press

this button after replacing Plasmacluster Ion

Generating Unit.

Do not press it for any other purpose.

(This is to reset the Unit Replacing Light.)

Power Cord

Plug

E-3

IG-A10EU.Eng.indd5IG-A10EU.Eng.indd5 2009/07/2113:08:502009/07/2113:08:50

INSTALLATION POSITION

Place the main unit on a smooth,

DO NOT USE the below items near the unit.

stable surface in a room and

insert the plug into an outlet.

silicone-containing products*

DO NOT hold the louvers when carrying the unit.

SPRAY

WAX

PESTICIDE

Installation Guidance.

Leave at least 15cm of clearance behind the Unit.

UPSIDE More than 1m

* Hair care products, cosmetic products,

water proof sprays, polish glass cleaner,

BACKSIDE

wipe and wax.

More than 15cm

LEFT/RIGHT SIDE

More than 20cm

OPERATION

Press the operation button to directly turn on the power and

select the preferred mode.

Release high-density

LOW

Plasmacluster ions quietly.

Increase the volume of

Plasmacluster ions to increase

HIGH

the purifying capacity.

'OFF'

Power 'OFF'.

Louvers

The air comes from direction, which is stamped on the

louvers.

•When releasing ions to the entire room, put each louver in

an opposite direction.

•When releasing ions to the point to deodorize the adhering

odor on clothes, put both louvers in the same direction

.

E-4

IG-A10EU.Eng.indd6IG-A10EU.Eng.indd6 2009/01/2711:12:322009/01/2711:12:32

CLEANING AND MAINTENANCE

WARNING:

When cleaning the unit, be sure to rst unplug the power cord,

and never handle the plug with wet hands.

Electrical shock and/or bodily injury may occur as a result.

Main Unit

Every month or more often if necessary

Wipe with a dry soft cloth.

ENGLISH

<For Stubborn Dirt>

rt>

Use water and a mild detergent. And

then, wipe with a wet cloth.

Make sure to dry out the main unit.

Filter

Every 2 weeks or more often if necessary

Gently remove dust from the

<For Stubborn Dirt>

filters by using a vacuum

Detach the filter and remove dust with

cleaner.

using a vacuum cleaner.

Filter

Filter

* The lter is not disposable item, often clean it.

E-5

IG-A10EU.Eng.indd7IG-A10EU.Eng.indd7 2009/01/2711:12:332009/01/2711:12:33

PLASMACLUSTER ION GENERATING UNIT REPLACEMEN

T

In order to release Plasmacluster Ion stably, periodical Plasmacluster

Ion Generating Unit replacement

is necessary. The Unit Replacing

Light will be ON as a reminder for replacement.

Elapsed Time

Display

Message

Beginning to use

lighting

(blue)

approx. 2 years

ashing(red)

Suggest replacing

(approx. 17,500hours)

lighting

(blue)

Stop working

approx. 2 years and

Replace the

ashing faster

2 months

Plasmacluster

(red)

(approx.19,000hours)

Ion Generating

Unit

Plasmacluster Ions

All light are

Error*

are not released.

ashing

* Usage environment affects the lifetime of the Plasmacluster Ion Generator.

The Plasmacluster Ion Generator may stop working before estimated lifetime.

In this case, press Operation button again and restart.

If this does not help, replace with a new Plasmacluster Ion Generating Unit.

Replacement of Plasmacluster Ion Generating Unit

<For Disposal>

Plasmacluster Ion Generating Unit

Please dispose the used Plasmacluster

Ion Generating Unit according to any local

Model Number

IZ-CA10E

laws and regulations.

-materials-

Case : Polystyrene

Unit : Polystyrene Terephthalate, Electric

parts

E-6

IG-A10EU.Eng.indd8IG-A10EU.Eng.indd8 2009/01/2711:12:332009/01/2711:12:33

HOW TO REPLACE THE PLASMACLUSTER

ION GENERATING UNIT

* When replacing the Plasmacluster Ion Generating Unit, be sure to turn off the

main unit, unplug the power cord, and never handle the plug with wet hands.

Remove the

1

LOUVERS.

Remove the TOP

2

COVER CAP.

ENGLISH

Turn the 2 SCREWS

3

SCREWS

Lift up the TOP

4

COVER.

Replace the

5

Plasmacluster Ion

Generating Unit.

* See the manual of Plasmacluster Ion

Generating Unit for replacement.

E-7

IG-A10EU.Eng.indd9IG-A10EU.Eng.indd9 2009/01/2711:12:332009/01/2711:12:33

SPECIFICATIONS

Model

IG-A10EU

Power supply

220-240V, 50/60Hz

Power consumption (W)

(High)

14.0

(Low) 6.5

Air ow volume (m

3

/hour)

(High) 102

(Low) 72

Applicable oor surface area (m

2

)*

10

Power cord (m)

1.8

Outer dimensions (mm)

140 160 345 (W D H)

Weight (kg)

2.5

3

*The target oor surface area for which an emitted airborne ion density of about 25,000 ions/cm

can

be measured at a point near the center of the room (at a height of about 1.2 m from the oor), during

operation at the HIGH mode when the main unit is placed near a wall.

The number of ions will vary according to the room conditions and the main unit operation mode.

TROUBLESHOOTING

Before calling for service, please review the TROUBLESHOOTING chart below,since the problem may

not be Plasmacluster Ion Generator malfunctions.

Problem

WHAT TO DO

The Plasmacluster Ion Generator

Make sure to put in the plug.

does not work.

Approx. 2 years and 2 months (approx. 19,000

hours) has been passed.

Replace with a new Plasmacluster Ion

ashing faster

Generating Unit. See page E-6,7.

(red)

Plasmacluster Ions are not released.

Press the Operation button and restart.

If all lights keep ashing, replace with new

ashing (red)

Plasmacluster Ion Generating Unit. See page E-6,7.

ashing (blue)

Dust may block the lter, clean the lter.

ashing (blue)

Failure

Unplug and contact the store you purchased or

Sharp Service Center.

ashing (blue)

The discharged air has odor. The Plasmacluster Ion Generator releases a

small trace of ozone which may produce odor.

This is not harmful to health.

A clicking or ticking sound comes

Loudness can be changed depending on a room

from the unit while operating the

humidity, but the effectiveness is the same.

Plasmacluster Ion Generator.

Relocate the Plasmacluster Ion Generator if

necessary.

E-8

IG-A10EU.Eng.indd10IG-A10EU.Eng.indd10 2009/06/1710:37:192009/06/1710:37:19

A. Information on Disposal for Users (private households)

1. In the European Union

Attention: If you want to dispose of this equipment, please do not use the ordinary dust

bin!

Used electrical and electronic equipment must be treated separately and in

accordance with legislation that requires proper treatment, recovery and recycling of

Attention: Your product is

used electrical and electronic equipment.

marked with this symbol. It

Following the implementation by member states, private households within the EU

means that used electrical

states may return their used electrical and electronic equipment to designated

and electronic products

collection facilities free of charge*. In some countries* your local retailer may also

should not be mixed with

take back your old product free of charge if you purchase a similar new one.

general household waste.

*) Please contact your local authority for further details.

There is a separate

collection system for these

products.

If your used electrical or electronic equipment has batteries or accumulators, please

dispose of these separately beforehand according to local requirements.

ENGLISH

By disposing of this product correctly you will help ensure that the waste undergoes

the necessary treatment, recovery and recycling and thus prevent potential negative

effects on the environment and human health which could otherwise arise due to

inappropriate waste handling.

2. In other Countries outside the EU

If you wish to discard this product, please contact your local authorities and ask for the

correct method of disposal.

For Switzerland: Used electrical or electronic equipment can be returned free of

charge to the dealer, even if you don’t purchase a new product. Further collection

facilities are listed on the homepage of

www.swico.ch or www.sens.ch.

B

. Information on Disposal for Business Users.

1. In the European Union

If the product is used for business purposes and you want to discard it:

Please contact your SHARP dealer who will inform you about the take-back of the

product. You might be charged for the costs arising from take-back and recycling.

Small products (and small amounts) might be taken back by your local collection

facilities.

For Spain: Please contact the established collection system or your local authority for

take-back of your used products.

2. In other Countries outside the EU

If you wish to discard of this product, please contact your local authorities and ask for

the correct method of disposal.

EN

IG-A10EU.Eng.indd11IG-A10EU.Eng.indd11 2009/01/2711:12:342009/01/2711:12:34

IG-A10EU.Ger.indd2IG-A10EU.Ger.indd2 2009/01/2711:08:072009/01/2711:08:07

DEUTSCH

INHALT

...................

WICHTIGE SICHERHEITSHINWEISE

G-2

..............................................................

• WARNUNG

G-2

.............

VORSICHTSMAßNAHMEN FÜR DEN BETRIEB

G-2

.....................................

• INSTALLATIONSANLEITUNG

G-2

...........................................

TEILEBEZEICHNUNG

G-3

...................................................................

• VORDERSEITE

G-3

........................................................................

• RÜCKSEITE

G-3

....................................................

AUFSTELLPOSITION

G-4

.............................................................................

BETRIEB

G-4

..........................................

REINIGUNG UND PFLEGE

G-5

....................................................................

• HAUPTGERÄT

G-5

.................................................................................

• FILTER

G-5

DEUTSCH

AUSTAUSCH DER PLASMACLUSTER-IONEN

........................................

GENERIERENDEN EINHEIT

G-6

SO TAUSCHEN SIE DIE PLASMACLUSTER-IONEN

........................................

GENERIERENDE EINHEIT AUS

G-7

....................................................

TECHNISCHE DATEN

G-8

...............................................................

FEHLERSUCHE

G-8

Der IG-A10EU kann zwar in der Luft schwebende Viren und

andere Kontaminationen deaktivieren und eliminieren, jedoch

keine vollständig sterile Umgebung herstellen. SHARP garantiert

nicht dessen Eignung zur Verhütung mikrobiologischer Infektionen.

Um gleichbleibende Emission hoch-verdichteter Plasmacluster-Ionen

zu ermöglichen, muss die im IG-A10EU eingebaute Plasmacluster-

Ionen generierende Einheit regelmäßig ausgetauscht werden*.

*

Ersatz ist bei 24-Stunden-Betrieb am Tag etwa alle 2 Jahre (17 500 Stunden)

erforderlich. Der IG-A10EU wird nach ca. 26 Monaten (19 000 Stunden) den Betrieb

einstellen, wenn die Plasmacluster-Ionen generierende Einheit nicht ausgetauscht wird.

Wir danken Ihnen herzlich für den Kauf dieses SHARP Plasmacluster-Ionen-

Generators. Bitte lesen Sie diese Bedienungsanleitung sorgfältig durch, bevor

Sie den Plasmacluster-Ionen-Generator in Betrieb nehmen.

Bewahren Sie die Bedienungsanleitung, nachdem Sie sie gelesen haben, an

einem leicht zugänglichen Ort auf, damit Sie bei Bedarf nachschlagen können.

G-1

IG-A10EU.Ger.indd3IG-A10EU.Ger.indd3 2009/01/2711:08:072009/01/2711:08:07

WICHTIGE SICHERHEITSHINWEISE

Bei der Verwendung elektrischer Geräte müssen grundlegende Vorsichtsmaßnahmen beachtet werden, einschließlich der Folgenden:

WARNUNG - Um das Risiko eines elektrischen Schlages, Brandes oder Verletzungen zu reduzieren:

• Lesen Sie alle Anweisungen vor Inbetriebnahme des Gerätes.

• Verwenden Sie ausschließlich eine Steckdose mit einer Spannung von 220-240 Volt.

Nehmen Sie das Gerät NICHT in Betrieb, wenn das Netzkabel oder der Netzstecker beschädigt

ist oder wenn der Anschluss an die Steckdose gelockert ist.

• Entfernen Sie regelmäßig Staub vom Stecker.

• Stecken Sie NIEMALS Ihre Finger oder Fremdkörper in den Lufteinlass oder -auslass.

Halten Sie das Netzkabel bei Abtrennen des Netzsteckers stets am Stecker selbst und niemals am Kabel fest.

Anderenfalls kann es zu einem Kurzschluss und dadurch zu einem elektrischen Schlag und/oder Brand kommen.

• Ziehen Sie den Stecker NICHT mit feuchten Händen raus.

• Betreiben Sie das Gerät NICHT in der Nähe von Gasgeräten oder offenen Kaminen.

Falls das Netzkabel beschädigt ist, muss es durch den Hersteller, einen Kundendienst, ein durch Sharp autorisiertes

Kundendienst-Center oder durch einen quali zierten Techniker ausgetauscht werden, um Gefahren zu vermeiden.

• Seien Sie bei der Reinigung des Gerätes vorsichtig.

Stark ätzende Reinigungsmittel können das Gehäuse beschädigen.

• Betreiben Sie das Gerät NICHT in Bereichen, in denen es feucht werden könnte.

Verwenden Sie KEINE Spray-Produkte in der Nähe des Gerätes.

Betreiben Sie das Gerät NICHT in Räumen, in denen ölige Bestandteile, Weihrauch, Zigaretten-

Funken und chemische Dämpfe vorhanden sind.

Nehmen Sie das Gerät NICHT in Betrieb, wenn Sie Insektenspray verwenden oder in Räumen, in denen ölige

Rückstände, Weihrauch, Funken von bennenden Zigaretten, chemische Dämpfe o.ä. in der Luft vorhanden

sind. Dasselbe gilt für Räume, in denen das Gerät feucht werden könnte, wie zum Beispiel Badezimmer.

Die Servicearbeiten an diesem Plasmacluster-Ionen-Generator sollten ausschließlich durch ein

von Sharp autorisiertes Kundendienst-Center ausgeführt werden. Wenden Sie sich bei jeglichen

Problemen, erforderlichen Einstellungen oder Reparaturen an ein Kundendienst-Center in Ihrer Nähe.

Dieses Gerät darf nicht von Personen (einschließlich Kindern) verwendet werden, die über

eingeschränkte körperliche, Sinnes- oder geistige Fähigkeiten verfügen, oder denen es an

Erfahrung und Wissen fehlt, es sei denn, sie wurden von Personen, die für ihre Sicherheit

verantwortlich sind, in die Benutzung des Gerätes eingewiesen und dabei beaufsichtigt.

• Kinder sollten beaufsichtigt werden, um sicher zu gehen, dass sie nicht mit dem Gerät spielen.

VORSICHTSMAßNAHMEN FÜR DEN BETRIEB:

Verdecken Sie NICHT den Lufteinlass und/oder Luftauslass.

• Betreiben Sie das Gerät NICHT in der Nähe heißer Gegenstände, wie Öfen oder Heizgeräten,

oder an Orten, an denen es mit heißem Dampf in Berührung kommen könnte.

Betreiben Sie das Gerät stets in aufrecht stehender Position.

Reinigen Sie das Gerät nur mit einem weichen Tuch, anderenfalls könnte die Oberfläche

beschädigt werden oder es könnten sich Risse bilden.

Halten Sie das Gerät von Wasser fern.

INSTALLATIONSANLEITUNG:

Plazieren Sie das Gerät in mindestens 2 Meter Entfernung zu anderen Geräten, die elektrische Strahlung aussenden,

wie Fernseher oder Radiogeräte, um elektrische Störungen während des Betriebes des Gerätes zu vermeiden.

Vermeiden Sie eine Verwendung an Orten, an denen das Gerät Kondensation oder drastischen

Temperaturschwankungen ausgesetzt ist. Die angemessene Raumtemperatur liegt zwischen 0 und 35°C.

Vermeiden Sie Räumlichkeiten, in denen Fett oder öliger Rauch erzeugt wird, anderenfalls

könnten sich Risse an der Ober äche des Hauptgerätes bilden.

HINWEIS - Störung des Radio- oder Fernsehempfangs:

Falls dieser Plasmacluster-Ionen-Generator Störungen des Radio- oder Fernsehempfangs verursacht,

versuchen Sie, die Störung durch eine oder mehrere der folgenden Maßnahmen zu beheben:

Richten Sie die Empfangsantenne anders aus oder stellen Sie sie an einem anderen Ort auf.

Vergrößern Sie den Abstand zwischen dem Gerät und dem Radio/Fernsehgerät.

Schließen Sie das Gerät an eine Steckdose an, die mit einem anderen Stromkreis verbunden ist,

als die, an die das Radio/Fernsehgerät angeschlossen ist.

Wenden Sie sich an Ihren Händler oder an einen erfahrenen Radio/Fernsehtechniker.

G-2

IG-A10EU.Ger.indd4IG-A10EU.Ger.indd4 2009/01/2711:08:072009/01/2711:08:07

TEILEBEZEICHNUNG

VORDERSEITE

Lüftungsgitter

(Siehe G-4)

ANZEIGE

Geräteaustausch-

Obere

Leuchte

(rot)

(Siehe G-6)

Abdeckkappe

Schrauben

Hoch

(blau)

Luftauslass

Obere

Abdeckung

Betriebstaste

DEUTSCH

Plasmacluster-

Niedrig

(blau)

Ionen generierende

Lüftergeschwindigkeits-

Einheit

Anzeige

(Siehe G-6,7)

Filter (Lufteinlass)

Filter (Lufteinlass)

(Siehe G-5)

RÜCKSEITE

Verwenden Sie ein spitzes Objekt, z.B. eine

Kugelschreiberspitze, um diesen Knopf nach dem

Austausch der Plasmacluster-Ionen generierenden

Einheit einzudrücken.

Drücken Sie den Knopf zu keinem anderen Zweck.

(Dies dient zum Zurücksetzen der Geräteaustausch-Leuchte).

Netzkabel

Netzstecker

G-3

IG-A10EU.Ger.indd5IG-A10EU.Ger.indd5 2009/07/2113:19:512009/07/2113:19:51

AUFSTELLPOSITION

Plazieren Sie das Hauptgerät auf

Verwenden Sie die folgenden Gegenstände

einer ebenen, stabilen Ober äche

NICHT in der Nähe des Gerätes

in einem Raum und stecken Sie

Produkte, die Silikon enthalten*

den Netzstecker in eine Steckdose.

Halten Sie das Gerät beim Transport NICHT an

SPRAY

WACHS

PESTIZIDE

den Lüftungsgittern.

Aufbauanleitung.

Lassen Sie mindestens 15 cm Abstand hinter dem Gerät.

OBERSEITE Mehr als 1 m

* Haarp egeprodukte, Kosmetika,

Imprägnierspray, Glassreiniger,

Wischmittel und Wachs.

RÜCKSEITE

Mehr als 15 cm

LINKE/RECHTE SEITE

Mehr als 20 cm

BETRIEB

Drücken Sie die Betriebstaste, um den Strom direkt einzuschalten,

und wählen Sie den gewünschten Modus.

Ruhige Abgabe hochdichter

NIEDRIG

Plasmacluster Ionen.

Erhöhen der Menge der

Plasmacluster Ionen, um die

HOCH

Reinigungskapazität zu erhöhen.

'OFF'

Ausschalten.

Lüftungsgitter

Die Luft kommt aus der " " Richtung, die auf den

Lüftungsgittern aufgedruckt ist.

Wenn Sie Ionen in den gesamten Raum abgeben möchten,

stellen Sie jedes Lüftungsgitter in die entgegengesetzte Richtung.

Wenn Sie Ionen abgeben möchten, um an Kleidung anhaftende Gerüche

zu desodorieren, stellen Sie beide Lüftungsgitter in dieselbe Richtung.

G-4

IG-A10EU.Ger.indd6IG-A10EU.Ger.indd6 2009/01/2711:08:072009/01/2711:08:07

REINIGUNG UND PFLEGE

WARNUNG:

Wenn Sie das Gerät reinigen, überzeugen Sie sich zuerst, dass das Netzkabel

herausgezogen ist, und berühren Sie den Stecker niemals mit feuchten

Händen.

Anderenfalls kann es zu elektrischem Schlag und/oder Verletzungen kommen.

Hauptgerät

Jeden Monat oder häu ger, wenn erforderlich

Wischen Sie das Gerät mit einem trockenen,

weichen Lappen ab.

<Bei hartnäckigen Flecken>

rt>

Verwenden Sie Wasser und ein mildes Reinigungsmittel.

Danach mit einem feuchten Lappen abwischen.

Vergewissern Sie sich, dass das Hauptgerät

vollständig trocknet.

DEUTSCH

Filter

Alle 2 Wochen oder häu ger, wenn erforderlich

Entfernen Sie den Staub sanft

<Bei hartnäckiger Verschmutzung>

mit einem Staubsauger von

Nehmen Sie den Filter ab und entfernen

den Filtern.

Sie den Staub mit einem Staubsauger.

Filter

Filter

* Der Filter ist kein Wegwerfartikel, reinigen Sie ihn

daher häu g.

G-5

IG-A10EU.Ger.indd7IG-A10EU.Ger.indd7 2009/01/2711:08:082009/01/2711:08:08

AUSTAUSCH DER PLASMACLUSTER-

IONEN GENERIERENDEN EINHEIT

Um gleichbleibend Plasmacluster-Ionen abzugeben, ist der regelmäßige Austausch

der Plasmacluster-Ionen generierenden Einheit erforderlich. Das Geräteaustausch-

Licht bleibt währenddessen AN, als Erinnerung an den Austausch.

Abgelaufene Zeit

Anzeige

Meldung

Betriebsbeginn

leuchtet

(blau)

Ca. 2 Jahre

blinkt (rot)

Austausch empfohlen

(ca. 17 500 Stunden)

leuchtet

(blau)

Betrieb gestoppt

Ca. 2 Jahre und

Tauschen Sie die

blinkt schnell

2 Monate

Plasmacluster-Ionen

(rot)

(ca. 19 000 Stunden)

generierende Einheit

aus

Plasmacluster-

Alle Lichter

Ionen werden nicht

Fehler*

blinken

abgegeben.

*

Die Nutzungsumgebung beeinträchtigt die Lebensdauer des Plasmacluster-Ionen-Generators.

Der Plasmacluster-Ionen-Generator kann vor der erwarteten Lebensdauer den Betrieb einstellen.

Drücken Sie in diesem Fall erneut die Betriebstaste und starten Sie neu.

Wenn das nicht hilft, ersetzen Sie die Plasmacluster-Ionen-Generator Einheit

durch eine neue Einheit Unit.

Austausch der Plasmacluster-Ionen generierenden Einheit

Plasmacluster-Ionen

<Zur Entsorgung>

generierende Einheit

Bitte entsorgen Sie die gebrauchte Plasmacluster-

Ionen generierende Einheit entsprechend den

Modellnummer

IZ-CA10E

örtlichen Gesetzen und Bestimmungen.

-Materialien-

• Gehäuse: Polystyrol

Einheit: Polystyrol Terephthalat, Elektronische Teile

G-6

IG-A10EU.Ger.indd8IG-A10EU.Ger.indd8 2009/01/2711:08:082009/01/2711:08:08

SO TAUSCHEN SIE DIE PLASMACLUSTER-

IONEN GENERIERENDE EINHEIT AUS

* Wenn Sie die Plasmacluster-Ionen generierende Einheit austauschen, vergewissern

Sie sich bitte, dass Sie das Hauptgerät ausgeschaltet und das Netzkabel

herausgezogen haben. Berühren Sie den Netzstecker niemals mit feuchten Händen.

Entfernen Sie die

1

LÜFTUNGSGITTER.

Entfernen Sie

2

die OBERE

ABDECKKAPPE.

Lösen Sie die 2

3

SCHRAUBEN.

DEUTSCH

SCHRAUBEN

Klappen Sie

4

die OBERE

ABDECKUNG auf.

Tauschen Sie die

5

Plasmacluster-

Ionen generierende

Einheit aus.

* Siehe Bedienungsanleitung zum

Austausch der Plasmacluster-Ionen

generierenden Einheit.

G-7

IG-A10EU.Ger.indd9IG-A10EU.Ger.indd9 2009/01/2711:08:082009/01/2711:08:08

TECHNISCHE DATEN

Modell

IG-A10EU

Stromanschluss

220-240V, 50/60Hz

Stromverbrauch

(W)

(Hoch)

14,0

(Niedrig) 6,5

Luft uss-Volumen (m

3

/Stunde)

(Hoch) 102

(Niedrig) 72

Maßgeblicher Boden ächenbereich (m

2

)*

10

Netzkabel (m)

1,8

Abmessungen (mm)

140 160 345 (B T H)

Gewicht (kg)

2,5

*

Der angestrebte Bodenflächenbereich, für den die an die Luft abgegebene Ionen-Dichte von ca. 25 000

Ionen/cm3 an einem Punkt nahe der Raummitte gemessen werden kann (bei einer Höhe von etwa 1,2m vom

Boden aus), während das Hauptgerät in der Nähe einer Wand plaziert und im Modus HIGH betrieben wird.

Die Anzahl der Ionen wird den Raumbedingungen und dem Betriebsmodus des Hauptgerätes entsprechend variieren.

FEHLERSUCHE

Sehen Sie sich bitte die untenstehende Tabelle zur FEHLERSUCHE an, bevor Sie sich an den Kundendienst wenden,

da es sich bei Problemen möglicherweise nicht um eine Fehlfunktion des Plasmacluster-Ionen-Generators handelt.

Problem

ABHILFEMASSNAHME

Der Plasmacluster-Ionen-Generator

Überprüfen Sie, ob der Netzstecker

funktioniert nicht.

angeschlossen ist.

Es sind etwa 2 Jahre und 2 Monate (etwa

19000h) vergangen. Ersetzen Sie die

Plasmacluster-Ionen generierende Einheit.

blinkt schnell

Siehe Seite G-6,7

(rot)

Es werden keine Plasmacluster-Ionen abgegeben.

Drücken Sie die Betriebstaste und starten Sie neu.

Wenn alle Leuchten ständig blinken, ersetzen Sie die

blinkt (rot)

Plasmacluster-Ionen generierende Einheit. Siehe Seite G-6,7.

blinkt (blau)

Staub könnte den Filter verstopfen, reinigen Sie den Filter.

blinkt (blau)

Betriebsstörung

Kontaktieren Sie den Händler bei dem das Gerät

erworben wurde oder das Sharp Service Center.

blinkt (blau)

Der Plasmacluster-Ionen-Generator gibt eine

Die abgegebene Luft enthält

geringe Spur von Ozon ab, die zu Geruch führen

Gerüche.

kann. Dies ist nicht gesundheitsschädlich.

Das Gerät erzeugt ein klickendes

Die Lautstärke kann sich abhängig von der

oder tickendes Geräusch, während

Luftfeuchtigkeit des Raumes ändern, die

der Plasmacluster-Ionen-Generator

Effektivität bleibt jedoch gleich.

betrieben wird.

Falls erforderlich, stellen Sie den Plasmacluster-

Ionen-Generator an einem anderen Platz auf.

G-8

IG-A10EU.Ger.indd10IG-A10EU.Ger.indd10 2009/07/2113:19:532009/07/2113:19:53