Dimplex SRX 160C: Cooling mode

Cooling mode: Dimplex SRX 160C

background image

- 3 - 

Cooling mode 

The  cooling  function  is  only  available  if  cooling  mode  has 

been set on the heat pump. 

Press the 

 button once or several times until the yellow 

indicator lights up. 

Set  the  desired  room  temperature  with  the  setting  wheel. 

Depending  on  the  current  room  temperature  and  the  tem-

perature  set  on  the  thermostat,  the  electronics  calculate 

which fan level (fan speed) to use.  

There are 3 possible fan levels. If necessary, the number of pos-

sible fan levels can be reduced. For  instance,  to  limit  the  fan 

levels to a maximum of 2, press the 

 button once or sev-

eral times until the red 

2

 indicator lights up. 

Changing automatically the set temperature 

You can change the set temperature automatically using a suit-

able programming cassette or by directly activating the control 

conductor, for example with an external timer. 

How the  set temperature is changed depends on the  selected 

operating mode: 

- In heating mode the set temperature is lowered 

- In cooling mode the set temperature is increased  

If  there  is  a  control  signal,  then  depending  on  the  selected 

mode, either the   indicator lamp (heating) or the 

 indica-

tor lamp (cooling) flashes. 

The  temperature  change  is  forwarded  to  any downstream  de-

vices via the control conductor. 

Fault indication 

If the flow temperature is not within the required range (see ta-

ble  under  "Technical  data"),  operation  is  interrupted  and  the 

red indicator   flashes. 

In  this  case  you  should  check  that  the  settings  of  the  heating 

system and circulating pump are correct and that they are work-

ing  properly.  For  more  information,  please  refer  to  the  "Trou-

bleshooting" chapter. 

Operation with air/water heat pumps 

When operating with an air/water heat pump, particularly when 

temperatures  are  low  outside,  the  heat  pump's  buffer  tank 

must  be  at  a  temperature  of  at  least  14°C  to  ensure  that  the 

heat pump evaporator can thaw. You should therefore ensure 

that  thawing  has  taken  place  if  necessary  before  opening  the 

valves to the heating circuit. 

Troubleshooting 

The following causes can result in the unit producing insufficient 

output: 

Indicator   flashes: 

Insufficient flow temperature.  

See "Fault indication" 

Indicator  ,  

flashes: 

Set temperature automatically lowered or raised. 

See "Changing automatically the set temperature" 

Air trapped in heat exchanger: 

Disconnect device from power supply, remove casing  

and  bleed  heat  exchanger.  For  position  of  bleeder  screw, 

see fig. 4. 

Insufficient water flow rate through device: 

Adjust flow rate (hydraulic balance). To do this, close ther-

mostat valves on the other heaters. 

Dirt on heat exchanger: 

Clean heat exchanger, see "Maintenance". 

Cleaning outer surfaces 

The  heater  must  be  switched  off  and  cooled  for  cleaning.  The 

surfaces  of  the  heater  can  be  cleaned  by  wiping  with  a  soft, 

damp cloth and then dried. Do not use abrasive powder or fur-

niture polish to clean as these may damage the surface. 

During Installation: 

If  the  appliance  is  being  installed  in  a  dusty  environment  we 

recommend  covering  the  appliance  to  prevent  the  ingress  of 

dust.  

Maintenance – to be performed by a specialist 

Dust or lint that collects inside the heater must be removed at 

regular intervals. 

To do this, disconnect the device from the power supply, loosen 

the 4 fixing screws on the underside of the casing and carefully 

remove  the  casing  cover.  Remove  dirt  with  a  soft  brush  or  a 

vacuum cleaner.  

Build-up of air in the heat exchanger can be remedied by open-

ing the bleeder valve (fig. 4). 

Warranty 

We offer a two-year warranty for this device in accordance with 

our warranty conditions. 

United Kingdom  

Dimplex – a division of the GDC Group

Millbrook House  

Phone +44 0845 600 5111   

Grange Drive, Hedge End  

Fax +44 0148 977 3050 

Southampton, Hants, SO30 2DF  

www.dimplex.co.uk 

Republic of Ireland 

Dimpco Ltd

Airport Road 

Phone (+353) 01 842 839 

Cloghran 

Fax (+353) 01 842 839 

Co. Dublin 

www.dimpco.ie 

Subject to modifications