COMPONENTS

MODEL E24SB, E35SB, E42SB

Fig. 4

7

!1

!3

!2

8

1

9

3

7

4

2

6

5

!0

1 AC CIRCUIT BREAKER

8 SPARK PLUG

2 ENGINE SWITCH

9 CHOKE LEVER

3 AC RECEPTACLE

0 RECOIL STARTER

4 OIL FILLER CAP

A GROUND TERMINAL

5 OIL DRAIN PLUG

B MUFFLER

6 FUEL COCK

C FUEL TANK CAP

7 AIR CLEANER

061201_Hitachi.p65 06.12.20, 10:22 AMPage 7 AdobePageMaker6.5J/PPC

English

SPECIFICATIONS

8

Model

E24SB

Type

Brushless, Revolving Field, Self-exciting, 2-poles, Single phase

AC Voltage

50Hz

230V

Max. Output

50Hz

2,400W

Rated Output

50Hz

2,100W

Rated Current

9.1A

ALTERNATORENGINE

Voltage Regulator

Condenser Type

Power Factor

1.0

Model

MITSUBISHI GM182P

Type

Air-cooled, 4 cycle, OHV, Gasoline Engine

Displacement

181cm

3

Fuel

Regular Automobile Gasoline

Fuel Tank Capacity

3.8 L

Rated Continuous Operation

50Hz

3.0 h

Lubricating Oil

Engine Oil SE Class or Higher

Lubricating Oil Capacity

0.6 L

Starting System

Recoil Starter

Length × Width × Height

589 × 400 × 405 mm

SION

DIMEN-

Dry Weight

37 kg

Specifications are subject to change without notice.

Model

E35SB

E42SB

Type

Brushless, Revolving Field, Self-exciting, 2-poles, Single phase

AC Voltage

50Hz

230V

Max. Output

50Hz

3,500W

4,200W

Rated Output

50Hz

2,800W

3,600W

Rated Current

12.2A

15.7A

Voltage Regulator

Condenser Type

ALTERNATORENGINE

Power Factor

1.0

Model

MITSUBISHI GM291P

MITSUBISHI GM301P

Type

Air-cooled, 4 cycle, OHV, Gasoline Engine

Displacement

296cm

3

Fuel

Regular Automobile Gasoline

Fuel Tank Capacity

6.0 L

Rated Continuous Operation

50Hz

3.0 h

Lubricating Oil

Engine Oil SE Class or Higher

Lubricating Oil Capacity

1.0 L

Starting System

Recoil Starter

Length × Width × Height

683 × 492 × 485 mm

SION

DIMEN-

Dry Weight

55 kg

58 kg

Specifications are subject to change without notice.

061201_Hitachi.p65 06.12.20, 10:22 AMPage 8 AdobePageMaker6.5J/PPC

English

TRANSPORTING / STORAGE

Transporting

CAUTION: Units are heavy. Observe safe lifting procedures when transporting.

Before transporting generator, it is important to turn off both the engine switch and the

fuel cock. Keep generator level at all times to prevent fuel spillage. Fuel vapor or spilled

fuel may ignite.

WARNING: Contact with a hot engine or exhaust system can cause serious burns or fires.

Let the engine and muffler cool before transporting the generator.

Storage

Make sure that the generator storage area is free of excessive humidity and dust. Store the generator in dry, well-

ventilated area.

WARNING: Contact with a hot engine or exhaust system can cause serious burns or fires.

Let the engine and muffler cool before storing the generator.

ASSEMBLY

CAUTION: The generator is too heavy to be lifted by one person. Obtain assistance from others

before you try to move it. Otherwise, Serious injury can result from attempting to lift too

heavy an object.

NOTE: Install the wheel kit (option for E35SB, E42SB) before adding gasoline or engine oil to prevent

damage to the engine. If you are installing accessories after running the generator, be sure that the

fuel tank is empty, and that the fuel cock is turned to the off position, that is, horizontal to the

ground. Be sure that the oil is drained from the engine.

ACCESSORY

ASSEMBLING THE WHEEL KIT (optional)

(The Same Usage for E35SB, E42SB)

Fig. 5

9

061201_Hitachi.p65 06.12.20, 10:22 AMPage 9 AdobePageMaker6.5J/PPC

English

Assembly Procedures

1. Drain the oil by removing the oil drain plug.

2. Drain the gasoline by removing the cup of fuel cock.

3. Attach the wheels 2 to the wheel-shaft 1

4. Insert the split-pin 4 into the hole that is on the wheel-shaft 1, after putting in the washer 3 to the wheel-shaft,

for the prevention of detaching the wheels 2 from the wheel-shaft 1.

5. Prepare 2 sets of the above wheel-shaft assembly.

6. Attach the wheel-shaft assembly to the frame-base, making use of the brackets 5, the bolts 6, washers 8 and

nuts 7.

7. Finally, attach the above 2 wheel-shaft assemblies to the front and rear of the frame-base.

CAUTION: For your safety, don’t fail to fix the wheels with wheel brakes for the prevention of moving.

Don’t operate the generator set at an inclined foundation.

Parts Number: KY90076DA

APPLICATIONS

Power source of electric appliances and tools.

WARNING: HITACHI electronic controlled products should not be used with portable generators.

Irregular generator power could cause these products to fail.

Regarding other manufacturer's products, please contact the manufacturer to see if it is

safe to use the electronic controlled products with portable generators.

PREPARATION BEFORE OPERATION

Before starting the generator, check the oil and fuel levels. Be sure that the air cleaner is functioning. Follow the

guidelines below when adding oil and fuel.

NOTE: There is no oil in the engine crankcase when the generator is shipped. You must add oil before

starting the engine. Check the oil level before each use with the generator on a level surface and

the engine stopped.

Engine oil is a major factor affecting engine performance and service life. Non-

detergent and 2-stroke oils will damage the engine and are not recommended.

Use 4-stroke motor oil that meets or exceeds the requirements for API service

classification SE or Higher.

Always check the API SERVICE label on the oil container to be sure it includes

the letters SE or Higher. SAE 10W- 30 or 10W-40 is recommended for general,

all-temperature use. Other viscosities shown in Fig.6 may be used when the

average temperature in your area is within the indicated range.

CHECKING THE OIL

1. Remove the oil filler cap and wipe the dipstick clean.

2. Check the oil level by inserting the dipstick into the filler neck without screwing

it in.

3. If the test shows no oil markings, the oil is low.

4. If the level is low, add the recommended oil to the upper mark on the dipstick.

10

Single

grade

Multi

grade

Ambient

temperature

OIL FILLER CAP

(OIL GAUGE)

Fig. 6

Fig. 7

061201_Hitachi.p65 06.12.20, 10:22 AMPage 10 AdobePageMaker6.5J/PPC

English

OIL CAPACITY

NOTE: If the oil level is too low, the oil alert system will shutdown

the engine and prevent engine from restarting.

FUEL

WARNING: Gasoline is flammable and its vapor is explosive. To prevent fire or explosion, follow the

guidelines below:

Keep fuel out of the reach of children.

Refuel the generator in well-ventilated area. Do not refuel while engine is running or hot. Disconnect all

electrical loads and shut off the engine before refueling.

Do not overfill the fuel tank. Always allow room for fuel vapors to expand. If you overfill the tank, fuel

can overflow onto the hot engine. This can cause fire or explosion. After refueling, tightly close the fuel

tank cap.

Do not spill fuel. Fuel or fuel vapor may ignite. If fuel spills, make sure that the area is dry before

starting the engine.

Never smoke in the refueling area. Never allow open flames or sparks in area.

Store fuel in an approved container. Store fuel in a well ventilated area free of open flames or sparks.

FUEL TANK CAPACITY

Check the fuel and refill the tank if the fuel level is low. Refuel

carefully to avoid spilling fuel. Do not fill above the shoulder of

the fuel strainer. (until upper limit red line).

Use unleaded gasoline with a pump octane rating of 86 or

higher.

The engine is certified to operate on unleaded gasoline.

Unleaded gasoline produces fewer engine and spark plug

deposits and extends exhaust system life. Never use stale or

contaminated gasoline. Avoid getting dirt or water in the fuel

tank.

Always keep the fuel strainer in place while refueling.

OPERATION

STARTING GENERATOR

WARNING: Before starting the generator, be sure that you read and understand all the safety and

operating instructions in this manual.

1. Disconnect all electrioal loads from the generator.

11

OIL FILLER CAP

(OIL GAUGE)

UPPER LEVEL

LOWER LEVEL

HITACHI Model

Liters

E24SB

0.6

E35SB,E42SB

1.0

HITACHI Model

Liters

E24SB

3.8

E35SB,E42SB

6.0

Fig. 8

Fig. 9

LEVEL

(UPPER

LIMIT)

FUEL

FILTER

SCREEN

061201_Hitachi.p65 06.12.20, 10:22 AMPage 11 AdobePageMaker6.5J/PPC

English

2. Open the fuel cock.

3. Push the engine switch to the ON position.

4. Set the choke lever to “CLOSE” (arrow mark). Not necessary if the engine is

warm.

5. Pull the starter handle slowly until resistance is felt.

This is the “Compression” point. Return the handle to its original position

and pull swiftly.

Do not fully pull out the rope.

After starting, allow the starter handle to return to its original position

while still holding the handle.

If the engine fails to start after several attempts, repeat above procedures

with choke lever returned to “OPEN” position.

6. After the engine started, return the choke lever gradually to “OPEN” position.

7. Warm up the engine without a load for a few minutes.

NOTE: Do not allow the starter handle to snap back. Return it slowly by hand.

NOTE: If the oil level in the engine is low, the engine will not start. If the engine does not start, check the

oil level and add oil as needed.

NOTE: To ensure maximum oil lubrication, place the generator on a level surface.

12

OPEN

Fig. 10

Fig. 11

Fig. 12

Fig. 13

Fig. 14

Fig. 15

061201_Hitachi.p65 06.12.20, 10:22 AMPage 12 AdobePageMaker6.5J/PPC

English

USING ELECTRIC POWER

1. Turn off the switch(es) of the electrical appliance(s) before connecting to the

generator.

2. Insert the plug(s) of the electrical appliance(s) into the receptacle.

Use 16 ampere type receptacles.

Be sure that the total wattage of all appliances does not exceed the rated

output of the generator.

3. Turn on the switch(es) of the electrical appliances.

WARNING: Be sure to ground the generator if the connected electrical

equipment is grounded.

Fig. 16

NOTE: When the generator is overloaded, the circuit breaker will

automatically activate to protect the generator and stop its output.

Reduce the load to within the specified limits and reset the circuit

breaker. Following this, restart the generator.

U

I

T

B

R

E

C

A

R

K

I

E

C

R

P

T

R

E

E

S

S

E

S

T

O

R

Fig. 17

STOPPING THE GENERATOR

1. Turn off the power switch of the electric equipment or unplug the cord from

receptacle of the generator.

2. Allow the engine about 3 minutes to cool down at no-load before stopping.

3. Set the engine switch to “STOP” position.

4. Close (stop) the fuel cock.

13

CLOSE

Fig. 18

Fig. 19 Fig. 20

061201_Hitachi.p65 06.12.20, 10:22 AMPage 13 AdobePageMaker6.5J/PPC

English

OIL SENSOR

The oil sensor detects the fall in oil in the crankcase and automatically stops the engine when the oil level

fails down below the safety limit.

When engine has stopped automatically, check the oil level.

If the engine does not start by usual starting procedures, check the oil level.

Run

14

RECOMMENDED OIL LEVEL

OIL LEVEL

FLOAT SWITCH

OFF

SCOPE OF APPLICABILITY

It is recommended to use AC power sources within the following scope.

Scope of applicability

Applicable

Model

Remarks

instruments

50Hz

Light, Electric

E24SB

Up to 2,100W

• The instruments which

Heater, Radio,

require much starting

Television

current and some kinds of

E35SB

Up to 2,800W

motors may be unable to

be used even if they are

within the applicable

E42SB

Up to 3,600W

scope.

Motors with

E24SB

Up to 700W

single phase

• The breaker turns OFF

when the current

Alternating current (AC)

E35SB

Up to 900W

exceeding the applicable

scope is used or when the

applied instrument is

E42SB

Up to 1,100W

defective.

Stop

Fig. 21

WARNING: HITACHI electronic controlled products should not be used with portable generators.

Irregular generator power could cause these products to fail.

Regarding other manufacturer's products, please contact the manufacturer to see if it is

safe to use the electronic controlled products with portable generators.

Oil Level

OIL LEVEL

ON

Fig. 22

061201_Hitachi.p65 06.12.20, 10:22 AMPage 14 AdobePageMaker6.5J/PPC

English

TROUBLESHOOTING

If the engine does not start

1. Check the fuel tank for sufficient fuel. Refill with fresh gasoline if necessary.

2. Check the engine oil. Fill to the upper limit with fresh oil.

3. Ensure that the fuel cock is open. The fuel cock is open when the lever is perpendicular to the ground (straight

up and down).

4. Check that the spark plug cap is securely attached to the spark plug.

5. Inspect the air filter. Clean or replace it if necessary.

6. Disconnect all electrical loads from the generator, and turn the engine switch on.

7. Follow the starting procedures in this manual on page11.

If the engine still does not start

1. Pull the starter handle 5-6 times.

2. Remove and inspect the spark plug.

If the spark plug is dry:

1. Ensure that there is fresh fuel in the tank and that the fuel cock is open.

2. Reinstall the spark plug and spark plug cap.

3. Try to start the engine again by following the starting procedures in this manual on page11.

4. If the engine fails to start, take the generator to an authorized HITACHI service center.

If the spark plug is wet.

1. Clean, gap, or replace the spark plug.

2. Reinstall the spark plug and spark plug cap.

3. Try to start the engine again by following the starting procedures in this manual on page11.

4. If the engine fails to start, take the generator to an authorized HITACHI service center.

If there is no power to the receptacles

1. Disconnect all electrical loads from the generator.

2. Reconnect the electrical loads. Be sure that the plugs are securely connected to the receptacles.

3. If there is still no power at the receptacles, take the generator to an authorized HITACHI service center.

MAINTENANCE

IMPORTANCE OF MAINTENANCE

Good maintenance is essential for safe, economical, and trouble-free operation. It will also help reduce air

pollution.

WARNING: Improper maintenance or failure to correct a problem before operation can cause

malfunction, serious injury, or death. Always follow the inspection and maintenance

recommendation and schedules in this user’s manual.

The following pages include a maintenance schedule, routine inspection procedures, and

simple maintenance procedures using basic hand tools, to help you properly care for your

generator. If you are not comfortable with any maintenance procedure, have the generator

serviced by a professional technician.

Maintenance, replacement, or repair of the emission control devices and system may be

performed by any engine repair establishment or individual, using parts that are “certified”

to EU standards.

MAINTENANCE SAFETY

WARNING: Always follow the procedures and precautions in the owner’s manual. Failure to

properly follow maintenance instructions and precautions can lead to serious injury or

death.

SAFETY PRECAUTIONS

CAUTION: Make sure that the engine is off before you begin any maintenance or repairs.

This will eliminate several potential hazards, including:

15

061201_Hitachi.p65 06.12.20, 10:22 AMPage 15 AdobePageMaker6.5J/PPC

English

Carbon monoxide poisoning from engine exhaust. Be sure there is adequate ventilation whenever you

operate the engine.

Burns from hot parts. Let the engine and exhaust system cool before you touch it to prevent burns.

Injury from moving parts. Wear appropriate clothing, tie back long hair, and stay alert around the

generator to prevent injury from moving parts.

Read the instructions before you begin, and make sure you have the tools and skills required.

Your authorized service center knows your generator best and is fully equipped to do maintenance and repair.

To ensure the best quality and reliability, use only new genuine parts or their equivalents for repair or replacement.

CAUTION: To reduce the possibility of fire or explosion, be careful when working around gasoline.

Use only a nonflammable solvent, not gasoline, to clean parts. Keep smoking, sparks, and

flames away from all fuel-related parts.

MAINTENANCE SCHEDULE

NOTE: Initial oil change should performed after first 25 hours of use. Thereafter change oil every 50 hours.

Before changing oil, check for a suitable way to dispose of the old oil. Do not pour it down into

sewage drains, onto garden soil or into open streams, Your local zoning environmental regulations

will give you more detailed instructions on proper disposal.

Items marked with a required advanced skill and tools, so they should be done by the authorized

HITACHI Service Center.

16

Check the air cleaner

Check oil level and refill to the upper level before starting the engine.

Daily

Check all the points as follows:

Fuel level at fuel gauge, Oil and Fuel leakage, Bolt and nut tightening

Any damage of components.

Clean and wash air-cleaner element.

More often if used in dirty or dusty environments.

Change engine oil.

50 hours (Weekly)

(The initial oil change must be conducted after the first 25 hours operation.)

Check spark plug, and clean and adjust if necessary.

Check and clean the fuel cock.

Replace spark plug.

100 hours

Replace air-cleaner element.

Decarbonize cylinder head, valves and piston.

Inspect control panel components.

Check rotor and stator.

3 years

Replace engine mount rubber.

Overhaul engine.

Change fuel lines.

061201_Hitachi.p65 06.12.20, 10:22 AMPage 16 AdobePageMaker6.5J/PPC

English

ENGINE OIL CHANGE

Change engine oil every 50 hours.

(for a new engine, change oil after 25 hours.)

1. Drain oil by removing the oil drain plug and the oil filler cap while the engine

is warm.

2. Reinstall the oil drain plug and fill the engine with oil unit it reaches the upper

level on the oil filler cap.

Use fresh and high quality lubricating oil to the specified quantity.

If contaminated or deteriorated oil is used or the quantity of the engine oil

is not sufficient, the engine damage will result and its life will be greatly

shortened.

17

OIL FILLER

CAP

OIL DRAIN PLUG

(OIL GAUGE)

Wash your hands with soap and water after handling used oil.

Please dispose of used motor oil and containers in a manner that will not harm the natural environment. We

suggest you take it in a sealed container to your local service station or recycling center for reclamation. Do not

throw it in the trash, pour it on the ground or down the drain.

NOTE: Never operate the generator without oil cap tightly secured. Failure to do so could cause oil to spill

out of the engine.

AIR FILTER

Adirty air cleaner will restrict airflow to the carburetor. To prevent carburetor malfunction, service the air filter

regularly. Service more frequently when operating the generator in extremely dusty areas.

NOTE: Never run the generator without the air cleaner. Rapid engine wear will result.

1. Take out the air cleaner, clean it well in kerosene and dry it.

2. After wetting the element by clean engine oil, squeeze it tight by hand.

3. Lastly, put the element in the case and install it securely.

ELEMENT

Fig. 23

Fig. 24

Fig. 25

061201_Hitachi.p65 06.12.20, 10:22 AMPage 17 AdobePageMaker6.5J/PPC

English

CLEANING FUEL STRAINER (FUEL COCK)

The fuel strainer removes dirt and water in the fuel.

1. Remove the strainer cup and throw away water and dirt.

2. Clean the screen and strainer cup with gasoline.

3. Tightly fasten the cup to main body, making sure to avoid fuel leak.

18

BODY

SCREEN

GASKET

CUP

SPARK PLUG SERVICE

To service the spark plug, use plug wrench (standard accessory). Use

recommended spark plugs.

RECOMMENDED PLUG AND ELECTRODE CLEARANCE

To ensure proper engine operation, the spark plug must be properly gapped and

free of deposits.

CAUTION: If the engine has been running, the muffler will be very hot.

Be careful not to touch the muffler. Be sure to allow the

engine to cool before you touch the spark plug.

1. Remove the spark plug cap.

2. Clean any dirt from around the spark plug base.

3. Use a spark plug wrench to remove the spark plug.

4. Visually inspect the spark plug. Replace it if the insulator is cracked or

chipped.

Clean the spark plug with a wire brush if you plan to reuse it.

5. Measure the plug gap with the feeler gauge. Correct as necessary by

carefully bending the side electrode (Fig.27).

6. Check that the spark plug washer is in good condition. If it is not, thread the spark plug in by hand to prevent

cross threading.

7. After the spark plug is seated, tighten with a spark plug wrench to compress the washer. If you are installing a

new spark plug, tighten the spark plug 1/2 turn after it seats to compress the washer. If you are reinstalling a

used spark plug, tighten 1/8–1/4 turn after the spark plug seats to compress the washer.

NOTE: The spark plug must be securely tightened. An improperly tightened spark plug can become very

hot and could damage the engine. Never use spark plugs which have an improper heat range. Use

only the recommended spark plugs or equivalent.

ELECTRODE

CLEARANCE

Fig. 26

HITACHI Model

Plug

Electrode Clearance

E24SB

BPR6HS (NGK)

0.6 to 0.7mm (0.024" to 0.028")

E35SB,42SB

BPR5ES (NGK)

0.7 to 0.8mm (0.028" to 0.031")

Fig. 27

061201_Hitachi.p65 06.12.20, 10:22 AMPage 18 AdobePageMaker6.5J/PPC

English

PREPARATION FOR STORAGE

The following procedures should be followed prior to storage of your generator for periods of 3 months or longer.

1. Drain fuel from fuel tank carefully. Gasoline left in the fuel tank will eventually

deteriorate making engine-starting difficult.

2. Loosen the drain screw on the bottom of the carburetor float chamber, and

drain the fuel completely.

3. Change engine oil.

4. Check for loose bolts and screws, tighten them if necessary.

5. Clean generator thoroughly with oiled cloth. Spray with preservative if

available.

NEVER USE WATER TO CLEAN GENERATOR!

6. Pull starter handle until resistance is felt, leaving handle in that position.

7. Store generator in a well ventilated, low humidity area.

SERVICE AND REPAIRS

All quality generators will eventually require servicing or replacement of parts because of wear from normal use.

To assure that only authorized replacement parts will be used, all service and repairs must be performed by a

HITACHI AUTHORIZED SERVICE CENTER, ONLY.

19

1DRAIN

SCREW

Fig. 28

G/R C-BOX E/G

CB

R

GREEN

BLUE

OSU

MCFC

GREEN

GREEN

OS

WHITE

REC

REC

SW

SC

YELLOW

YELLOW

IG

BLACK

MC

RED

BLACK

C

SP

BLACK

YELLOW/

GREEN

ET

WIRING DIAGRAM

E24SB, E35SB, E42SB

Symbol

Parts Name Symbol Parts Name Symbol Parts Name

E/G

Engine

R

Rotor CP

CB

AC circuit breaker

G/R

Generator

OSU

Oil sensor unit

C

Capacitor

C-BOX

Control box

ET

Ground terminal

SW

Engine switch

MC

AC wiring

SP

Spark plug

IG

Ignition coil

SC

Auxiliary winding

REC

AC receptacle

FC

Field winding

OS

Oil sensor

Fig. 29

061201_Hitachi.p65 06.12.20, 10:22 AMPage 19 AdobePageMaker6.5J/PPC

English

20

061201_Hitachi.p65 06.12.20, 10:22 AMPage 20 AdobePageMaker6.5J/PPC

Оглавление