2. Level the part
Measuring features
7. Measure a distance
• Touch the MEASURE tab to display
Features are measured by touching a
Touch the DISTANCE icon and
the measure icons, and then touch
feature icon or the MEASURE MAGIC
probe 1 point on each end of the
the blue SKEW/LEVEL icon to display
icon in the MEASURE tab, probing
distance.
the SKEW and LEVEL icons.
points and then pressing the ENTER and
FINISH keys.
1. Measure a point
Touch the POINT icon and probe
8. Use Measure Magic
• Touch the LEVEL icon,
a point.
Touch the MEASURE MAGIC
probe a minimum of 3
icon and probe points on a
points on the desired part
2. Measure a line
feature. The feature type will
reference-plane surface
Touch the LINE icon and probe a
be determined based on the
and then press the FINISH
minimum of 2 points.
pattern and sequence of point
key.
probing.
Creating Features
3. Measure a circle
Features are created by selecting the
Touch the CIRCLE icon and
feature type to be created, entering the
probe a minimum of 3 points
required feature data and then pressing
in any order around the
the FINISH key.
circumference.
3. Perform a skew alignment
1. Specify the feature type
• Touch the MEASURE tab to display
Touch the MEASURE tab and then touch
the measure icons, and then touch
a measure icon to specify the type of
the SKEW/LEVEL icon
feature to be created.
4. Measure an arc
• Touch the SKEW icon, probe
Touch the CIRCLE icon once
a minimum of 2 points on
to display the ARC icon, then
the reference edge and then
touch the ARC icon and probe
press the FINISH key.
a minimum of 3 points in
2. Enter the feature data
sequence from beginning to end
Touch the ENTER DATA icon
of the arc.
and then enter data into fields
shown on the screen.
3. Complete the creation
Press the FINISH key to complete
the feature creation. The new created
5. Measure a slot
feature will be shown in the feature list.
Touch the SLOT icon and
probe 5 points in the following
Creating a zero datum
sequence:
Constructing Features
• Probe, construct or create a reference
• Two points on a long side
Features are constructed by selecting
point.
• One point in the closest end
the feature type to be constructed,
• Press the DRO button to
• One point in the center of the
selecting the parent features and then
display the DRO screen.
second long side
pressing the FINISH key.
• Press the ZERO buttons for each axis
• Last point on the remaining
on the DRO screen.
end
1. Specify the feature type
Points can be probed in
Touch the MEASURE tab and then touch
sequence in either direction.
a measure icon to specify the type of
Presetting a datum
feature to be constructed.
• Probe, construct or create a reference
point.
2. Select the parent features
• Display the DRO screen, touch the
Touch the desired parent features in the
axis values shown and enter preset
6. Measure an angle
feature list. Check marks will be shown
values using the numeric keypad.
Touch the ANGLE icon and
near the parent features.
probe a minimum of 2 points on
each of the two legs. Press the
3. Complete the construction
FINISH key after each leg.
Press the FINISH key to complete the
construction. The new constructed
feature will be shown in the feature list.
5

Operation
Viewing measurement data
Loading programs
Probed data points with form errors
Programs can be loaded from a USB
Note:
are viewed by selecting a feature in
drive.
Programs can also be copied and edited.
the feature list and touching the VIEW
• Plug the USB drive into the USB port
Refer to the User’s Guide for detailed
button.
on the side of the ND 1300.
information.
• Touch the C: DRIVE icon
1. Select a feature
to change drives. The A:
1. Recording a program
Touch the desired feature in the feature
(USB) DRIVE icon and list of
• Touch the PROGRAM tab.
list.
programs stored on the USB
drive will be shown,
2. Press the VIEW button
• Touch the desired program
Form errors are displayed as
name in the list and then
lines extending from data
• Touch the round red RECORD icon.
touch the LOAD PROGRAM
points to the feature. The
• Enter a program name and press the
icon. The highlighted program
two greatest form errors are
FINISH key to begin recording.
will be loaded to the local (C:)
shown in red.
• Perform part alignment, measurement
drive.
and other steps as usual. Program
• Touch the A: DRIVE icon. The
recording is indicated by a red
C: DRIVE will be shown with
Applying Tolerances
program tab.
the loaded program in the C:
Tolerances are applied by selecting
• To end recording, press the
DRIVE program list.
a feature, touching the TOL button,
PROGRAM tab and then press the
selecting a tolerance type and entering
The loaded program can now be
square black STOP icon. The new
tolerance data.
selected and run.
program will be stored.
1. Select a feature
3. Deleting a program
Touch the desired feature in the feature
• Touch the PROGRAM tab.
list.
• Touch a program name.
• Press the FINISH key to end the
• Press the CANCEL key. The program
2. Press the TOL button
programming session and return to
will be deleted.
Tolerance types are
the DRO.
displayed at the bottom
of the screen as tolerance
2. Running a program
Note:
icons.
• Touch the PROGRAM tab.
Use caution when deleting programs,
• Touch a program name.
and store a backup of the program first.
3. Select a tolerance
• Press the black triangular RUN icon.
Deleted programs cannot be restored.
Touch a tolerance icon to select the
The feature type and points probed
• Press the FINISH key to end the
desired tolerance type and then touch
will be displayed as points are probed.
the word TOLERANCE at the top left
• After establishing a datum, press the
programming session and return to
the DRO.
corner of the screen to select a specific
VIEW button to see point targeting
tolerance.
while points are probed.
• The program will stop automatically
Reporting Results
4. Enter tolerance data
when all program steps have been
Reports of results can be sent to a USB
Enter NOMINAL and TOLERANCE data
played. A message box will be
printer, USB flash drive or a PC. The
into data fields provided in the tolerance
displayed.
report type and destination are specified
screen.
• Touch the message box to end the
in the PRINT setup screen.
programming session and return to
5. View the result
the DRO.
Green squares near features in the
Note:
feature list indicate passed tolerances.
Saving programs
Refer to the ND 1300 user guide on our
Red squares and outlined characters
Programs can be saved to a USB drive.
web site at: www.heidenhain.de for
on the DRO screen indicate failed
• Plug an empty USB drive into the USB
details.
tolerances.
port on the side of the ND 1300.
• Touch the PROGRAM tab and touch
• Press the SEND key to report
Programming
the program name.
results.
Programs are recorded sequences
• Touch the COPY PROGRAM
of measurement and other operator
icon.
activities stored by the ND 1300 to
be played back later when inspecting
• Press the FINISH key to return to the
identical parts. This guide discusses
DRO.
recording, running, saving, loading and
deleting programs.
6
Оглавление
- ND 1300 QUADRA-CHEK
- ND 1300 QUADRA-CHEK English Setup
- Setup
- Setup Operation
- Operation
- ND 1300 QUADRA-CHEK Deutsch Setup
- Setup
- Setup Bedienung
- Bedienung
- ND 1300 QUADRA-CHEK Français Paramétrage
- Paramétrage
- Paramétrage Présentation
- Présentation
- ND 1300 QUADRA-CHEK Italiano Configurazione
- Configurazione
- Configurazione Funzionamento
- Funzionamento
- ND 1300 QUADRA-CHEK Español Ajustes
- Ajustes
- Ajustes Operación
- Operación
- ND 1300 QUADRA-CHEK Svenska Inställning
- Inställning
- Inställning Handhavande
- Handhavande
- ND 1300 QUADRA-CHEK Nederlands Instellen
- Instellen
- Instellen Bediening
- Bediening
- ND 1300 QUADRA-CHEK Česky Nastavení
- Nastavení
- Nastavení
-
- ND 1300 QUADRA-CHEK Português Configurar
- Configurar
- Configurar Funcionamento
- Funcionamento
- ND 1300 QUADRA-CHEK Język polski Setup
- Setup
- Setup
-
- ND 1300 QUADRA-CHEK Русский
-
-
- ND 1300 QUADRA-CHEK Nihongo
-
-
-
- ND 1300 QUADRA-CHEK Zhongwen (zh_TW)
-
-
-
- ND 1300 QUADRA-CHEK
-
-
- ND 1300 QUADRA-CHEK