Jotul I530FL: 1.0 Regulatory information

1.0 Regulatory information: Jotul I530FL

background image

14

ENGLISH

Table of contents

Installation manual with technical data

1.0   Regulatory information ..............................14

2.0   Technical data  .............................................14

3.0   Installation  .................................................15

4.0   Servicing ...................................................... 17

5.0   Optional Equipment ................................... 17

Figures .................................................................. 43

General use and maintenance manual

6.0  

Safety 

precautions

7.0   Choice of fuel

8.0  

Use

9.0  

Maintenance

10.0   Operational problems - troubleshooting

On all our products there is a label 

indicating the serial number and 

year. Write this number in the 

place indicated in the installation 

instructions. 

Always quote this serial number when 

contacting your retailer or Jøtul.

les combustibles recommandés.

Respectez les consignes d'utilisation. Utilisez uniquement

Verwenden Sie nur empfohlenen Brennstoffen.

Montage- und Bedienungsanleitung beachten. 

Follow user`s instructions. Use only recommended fuels.

standard

Certificate/

The appliance can be used in a shared flue.

Minimum distance to adjacent combustible materials:

Emission of CO in combustion products

Serial no: Y-xxxx, Year: 200x

Manufacturer:

N-1602 Fredrikstad

Norway

Jøtul AS

POB 1441

Sweden

EUR

Intermittent

Nominal heat output      

Norway

Country

Operational type

Fuel type

Operation range

Efficiency

Klasse II

Classification

Standard

Flue gas temperature             

Room heater fired by solid fuel

Product:

Jøtul

SP Sveriges Provnings- och

221546

Forskningsinstitut AB

SP Swedish National 

Testing and Research

Institute

:

Approved by

:

:

:

:

:

:

:

Minimum distance to adjacent combustible materials:

OGC 

SP 

EN 

Serial no.

1.0 Regulatory information

Installation of a fireplace must be according to local codes and 

regulations in each country.

All local regulations, including thosethat refer to national and 

European standards, shall be complied with when installing the 

product.

Both an installation manual with technical data and a general 

user and maintenance manual accompany the product. The 

installation can only be taken into use after it has been checked 

by a qualified inspector.

An approval label made of heat resistant material is located 

on the heat shield at the back of the product. This contains 

information about identification and documentation for the 

product.

2.0 Technical data

Material: Cast 

iron

Finish: Black 

paint

Fuel: Wood

Log length, max.: 

50 cm

Flue outlet: 

Top 

Flue dimension 

(outside the outlet) :  

200 mm/314 cm

2

 cross section 

Approx. weight: 

125 kg

Optional extras: 

Panels, glass ash lip and ash  

 solution 

Dimensions, distances etc.:  See 

fig.1

Technical data according to EN 13229

Nominal heat output: 

9,0 kW

Smoke gas mass flow: 

8,4 g/s

Recommended chimney draught:  12 Pa

Effiency: 71%@9,0 

kW

CO emission (13% O

2

): 0,25 

%

Flue gas temperature: 

350 

C

Operating mode:  

Intermittent

“Intermittent combustion” here means normal use of a stove. 

That is to say, if you want to continue producing heat, you add 

more fuel as soon as the previous load of wood has burnt down 