1. Operating Instructions

 for the user and engineer

1.1  Description of Unit

•  The closed (pressurized) water storage he-

ater keeps the water content permanently 

ready at the pre-selected temperature.

•  Only tap fittings in conjunction with the 

SVMT safety group may be used.

1.2  The most important points  

in brief

•  Set the desired hot water temperature 

using the temperature selector (

1

)

•  An illuminated display (

2

) indicates that 

the unit is heating up.

2

1

C26_02_06_0095

82

°C

35

55

65 Eco

comfort

1.3  Operation

Temperature setting

°C

  =  cold. At this setting the unit is pro-

tected from frost, although this does 

not protect the fitting or the water 

pipe.

Eco

  =  recommended energy-saving setting 

(approx. 60 °C), low limescale formati-

on

82

  =  max. temperature setting.

Note:

On request, the engineer can set a tempera-

ture limit on the unit (see .8 “First Use”) so 

that the temperature is fully adjustable up to 

this limit.

Heat up time:

If the entire water content is used, the heat up 

time is that shown on the diagram.

  35 °C   

55 °C  E  65 °C 

82 °C

[min]

  25

  20

  15

  10

5

0

 SHU 10 SLi

 SHU 5 SLi

Example SHU 5 SLi: 

Temperature setting: 

65 °C

Heat up time: 

approx. 

9.5 minutes

Mixing water quantity:

Using the temperature, you can set a mixing 

water quantity for 40°C, for example.

[ l ]

30

25

20

15

10

5

0

  40 °C 

55 °C  E  65 °C 

82 °C

 SHU 10 SL

 SHU 5 SL

Example SHU 5 SLi: 

Temperature setting: 

65 °C 

Cold water input: 

15 °C 

Mixing water quantity: 

approx. 

10 l

1.4  Important Note

• 

The water storage heater is under 

mains water pressure. 

• 

During heating up, water will drip out of 

the safety valve. 

If water continues to drip out of the safety 

valve after heating up has been completed, 

the device must be switched off and depres-

surized, and a qualified installer called. 

• 

The blow-out line of the safety valve must 

not be closed. 

• 

With temperature settings over 45 °C, wa-

ter at a high temperature may start flowing 

immediately. 

• If it is intended that children or people with 

restricted physical, sensory, or mental capa-

city are to operate the appliance, they may 

only be permitted to do so after appropriate 

instruction has been provided by the person 

responsible for their safety. 

Children should be supervised to ensure that 

they do not play with the device -  

Risk of scalding!

To avoid risk of accidental resetting of the 

protective temperature restrictor in the event 

of a fault, the unit must not be connected via 

a timer switch.

Limescale can block the outlet and cause pres-

sure to build up in the heater.

Signs of limescale are boiling sounds and re-

duced water flow. In such a case, the unit and 

fitting must be descaled by an engineer.

The thermostat knob may only be removed by 

an engineer.

All information in these Operating and In-

stallation Instructions must be observed. The 

instructions contain important information for 

safety, operation and maintenance of the unit.

1.5  Care and Maintenance

To clean the unit, simply wipe with a damp 

cloth. Do not use abrasive or aggressive clea-

ning agents.

Maintenance work should only be 

performed by an engineer.

1.6  What to do if ...

... there is no hot water:

Check the thermostat, plug and fuse.

... there is a boiling sound from the unit:

Have the unit and fitting descaled by an en-

gineer.

... see also 3. „Defect rectification for the user 

and engineer”.

If an engineer is called out for a problem, to 

help him resolve this problem quickly and effi-

ciently, please give him the information on the 

unit rating plate, as shown below (

8

):

Typ:

SNU 5 SL

Nr.: ...... - .... - ......

..............

C26_02_06_0010