The  rear  panel  of  the  Gigabit  Ethernet  Media 

Converter indicates one DC jack, which accepts input 

power with 5V DC 2A.

5V DC

+

Figure 6:

  GT-80x Left View

Side View (FT-80x)

One  DIP  switch  for  Link  Fault  Pass  Through  (LFP) 

feature,  "ON"  to  turn-on  the  LLCF  and  LLR  detection. 

And "OFF" to turn –off this feature. Please refer to the 

following sections for more.

OFF

ON

LFP

Figure 7:

  FT-80x Side View

4.  Link Fault Pass Through (LFP)

The LFP function includes the Link-Fault-Passthrough function (LLCF/LLR) and the DIP Switch design. LLCF/

LLR can immediately alarm administrators the problem of the link media and provide efficient solution to 

monitor the network. The DIP Switch will disable or enable the LFP function.

LLCF (Link Loss Carry Forward) means when a device connected to the converter and the TP line loss the 

link, the converter’s fiber will disconnect the link of transmit. LLR (Link Loss Return) means when a device 

connected to the converter and the fiber line loss the link, the converter’s fiber will disconnect the link of 

transmit.

Note

LFP  function  is  ON  by  default  setting.  If  you  are  familiar  with  the  network  installation 

and for diagnostic purpose (i.e. check which end is broken), you can turn it off and reset 

the converter to make it take effect. Otherwise, please remain it in the default position.

5.  Installing The Converter

To install FT-80x / GT-80x stand-alone, on a desktop or shelf, simply complete the following steps:

Step 1:

Turn  off  the  power  of  the  device/station  in  a  network  to  which  the  FT-80x  /  GT-80x  will  be 

attached.

Step 2:

Attach fiber cable from the FT-80x / GT-80x to the fiber network. 

TX

RX

 must be paired at both 