HP Designjet 10000s Printer series: III 55 Warnings ffor mmaintenance III 66 Protective eequipment
III 55 Warnings ffor mmaintenance III 66 Protective eequipment: HP Designjet 10000s Printer series
Table of contents
- I Introduction
- II Product ddescription
- III Safety III 11 General iinformation III 22 Use aas iintended III 33 Information oon ssigns aand ssymbols
- III 44 Warnings
- III 55 Warnings ffor mmaintenance III 66 Protective eequipment
- Index
- 1 Installation && FFunction DDescription 1.1 Warnings ffor mmaintenance
- 1.2 Unpacking aand iinstallation 1.3 Box ccontent
- 1.4 Connection oof tthe pprinter 1.5 Power oon tthe AAPS 1.6 Function ddescription
- 2 Operation 2.1 Operating cconditions 2.2 Operation
- 2.3 Test ooperation
- Designation
- Figure 1 Figure 2 Figure 3
- Figure 4 3.3.2 IInsert tthe nnew ffilter(s) Figure 5 Figure 6 Figure 7
- 3.4 Enter tthe ccode oof tthe nnew rreplacement ffilter 3.4.1 HHP DDesignjet 88000s AAir PPurifier SSystem
- 3.4.2 HP DDesignjet 99000s/10000s AAir PPurifier SSystem
- 4 Disposal
- 5 Troubleshooting
- 6 Legal iinformation
- 6.Your exclusive remedies for defective HP products are the following:
- B. Limitations of liability C. Local law
- 7 Regulatory nnotices 7.1 Regulatory mmodel nnumber 7.2 Regulatory sstatements
- 9 Technical ddata

III 55 Warnings ffor mmaintenance
The APS must be switched off for maintenance, and be secured against being switched on again
unexpectedly, by:
• the APS must be switched off at the ON/OFF switch and then
• the power plug must be removed from the wall power socket.
Do not put your hand in the cover grid of the fan during fitting, assembly or service work.
– After switching off /shutdown of the APS wait until the fan stops.
To avoid electric shocks do not open any electrical parts and casing and covers.
It is recommended to use protective gloves (disposable gloves made of polyethylene, latex or
Nitrile®) before carrying out the filters replacement and/or the suction hoses.
Replace filter elements at the stated intervals. Always tightly rescrew screw connections
loosened.
Do not use any aggressive agents or cleaning agents which contain solvents. Use lint-free
cleaning cloths.
Only use mild water-based cleaning agents. Do not use any organic solvents, as there is a risk
of fire and explosion!
Ensure ssafe aand eenvironmentally-ffriendly ddisposal oof mmaterials aand ssupplies.
III 66 Protective eequipment
The APS is equipped with safety interlocks to protect the user and is constructed and produced
in accordance with state-of-the-art- technology to meet operational safety regulations. In order
to ensure safe and environmentally-responsible operation, the following safety features have
been installed:
– The fan is secured by a protective plate or grid, which may only be removed using tools.
– All elements of the control systems will move into a safe status for operators, APS and
the environment in the case of power cut or reported disturbances. An unexpected
restart is not possible after this.
– All electrical parts carry the CE mark for low voltage and/or EMV.
– A potential compensation (Ø > 1.5 mm²) of all conducting components is installed to
ground the APS.
– The APS is designed according to protective type IP 20.
8 User´s Guide