To ensure accuracy, readings should be taken without clothing and under consistent conditions of hydration. If you do not 

undress, always remove your socks or stockings, and be sure the soles of your feet are clean before stepping onto the measuring 

platform. Be sure your heels are correctly aligned with the electrodes on the measuring platform. Don’t worry if your feet appear 

too large for the unit, accurate readings can still be obtained if your toes overhang the platform. It is best to take readings at the 

same time of day. Try to wait about three hours after rising, eating, or exercising before taking measurements. While readings 

taken under other conditions may not have the same absolute values, they are accurate for determining the percentage of change 

as long as the readings are taken in a consistent manner. To monitor progress, compare weight and body fat percentage taken 

under the same conditions over a period of time.

Note:  

An accurate reading will not be possible if the soles of your feet are not clean, or if your knees are bent or you are in a 

sitting position.

Do not pull the Hand-electrodes cable beyond the red band.

Handling Tips

This scale is a precision instrument utilising state-of-the-art technology.

To keep the unit in the best condition, please follow these instructions carefully:

Do not attempt to disassemble the measuring platform.

Store the unit horizontally, and place it so that the buttons will not be pressed accidentally.

Avoid excessive impact or vibration to the unit.

Place the unit in an area free from direct sunlight, heating equipment, high humidity, or extreme temperature change.

Never submerge in water. Use alcohol to clean the electrodes and glass cleaner (applied to a cloth first) to keep them shiny; 

avoid using soaps.

Do not step on the platform with wet feet.

Do not drop any objects onto the platform.

Do not carry the unit by holding the Hand-electrodes.

Do not release the Hand-electrodes unit the cable is completely retracted into the unit.

 Inserting the Batteries

Open the battery cover on the back of the measuring platform. Insert the supplied 

AA-batteries as indicated. 

Note:  

Be sure that the polarity of the batteries is set properly. If the batteries are incor-

rectly positioned the fluid may leak and damage floors. If you do not intend to use 

this unit for a long period of time, it is advisable to remove the batteries before 

storage.

Please note that the included batteries from the factory may have decreased energy levels 

over time.

 Positioning the Scale

Place the measuring platform on a hard, flat surface where there is minimal vibration to 

ensure safe and accurate measurement.

Note:  

To avoid possible injury, do not step on the edge of the platform.

Open as 

shown.

Direction of 

the batteries.

PREPARATIONS BEFORE USE GETTING ACCURATE READINGS AUTOMATIC SHUT-DOWN FUNCTION

The automatic shut-down function shuts off the power automatically in the following cases:

If you interrupt the measurement process. The power will shut down automatically within 20 to 60 seconds, depending upon 

the type of operation.

During programming, if you do not touch any of the buttons within 60 seconds.*

After you have completed the measuring process.